Which gas is appropriate for pressure testing a refrigeration system for leaks?
Answer: Dry nitrogen
Dry nitrogen is inert; oxygen or air with oil can cause an explosion.
What must be used on a nitrogen cylinder when pressurizing a system?
Answer: A pressure regulator
Cylinder pressure far exceeds system limits, so a regulator is required.
Test pressure should never exceed:
Answer: The lowest design pressure of any component, per the nameplate
Exceeding the lowest rated component pressure can rupture or damage equipment.
How should an electronic leak detector probe be moved along a joint?
Answer: Slowly, about an inch per second, close to the joint
Slow movement near the joint gives the sensor time to detect small leaks.
An ultrasonic leak detector works by sensing:
Answer: The high-frequency sound of escaping gas
Escaping gas generates ultrasonic noise that the detector converts to audible sound.
During a standing pressure test, a gauge drop may not mean a leak if:
Answer: Ambient temperature fell
Pressure of a gas drops as temperature drops, so temperature change can mimic a leak.
Under EPA rules, once a leak is found in an appliance with 50+ lb of ozone-depleting refrigerant over its trigger rate, repairs generally must occur within:
Answer: 30 days
EPA requires leak repairs within 30 days of discovering the leak rate exceeds the threshold.