Industry Regulations & Compliance Flashcards

7 cards from real EPA 608 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Industry Regulations & Compliance flashcards as text
  1. What is the term for processing used refrigerant to the purity of new product, verified by chemical analysis?

    Answer: Reclaiming

    Reclaiming restores refrigerant to AHRI Standard 700 purity and requires lab analysis.

  2. Which statement best describes recovery?

    Answer: Removing refrigerant from a system and storing it in an external container

    Recovery is removing refrigerant from a system and storing it, without necessarily testing or processing it.

  3. Under Section 608, the venting prohibition applies to which refrigerants?

    Answer: CFCs, HCFCs, and their substitutes such as HFCs

    Since 2018 the venting prohibition covers ozone-depleting refrigerants and substitutes such as HFCs.

  4. A technician must recover refrigerant before disposing of a small appliance. If the recovery equipment is self-contained and the compressor is NOT operating, what percent of refrigerant must be recovered?

    Answer: 80%

    Recovery is 90% with an operating compressor and 80% without.

  5. Which person is responsible for recovering refrigerant from a small appliance, such as a refrigerator, before final disposal when it enters the waste stream?

    Answer: The person who disposes of it, who must verify recovery

    The final disposer must ensure refrigerant is recovered and keep a signed statement from the supplier.

  6. What is the purpose of the Montreal Protocol, which the Clean Air Act supports?

    Answer: Phasing out production of ozone-depleting substances

    The Montreal Protocol is an international treaty that phases out ozone-depleting substances.

  7. Which of the following is a requirement for recovery cylinders regarding periodic testing?

    Answer: Hydrostatic testing every 5 years

    DOT-approved cylinders require hydrostatic retesting every 5 years.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ecfr.gov — Exam format, test delivery, fees, passing score, retake policy, score release · verified Oct 2026
  2. epa.gov — Test delivery, eligibility, renewal, score validity · verified Oct 2026