← All EPA 608 Flashcard Decks

Code Compliance & Standards Flashcards

7 cards from real EPA 608 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Code Compliance & Standards flashcards as text
  1. Under EPA leak repair rules for ozone-depleting refrigerants, what leak rate triggers repair for a commercial refrigeration appliance?

    Answer: 20%

    Commercial refrigeration appliances must be repaired when the annualized leak rate reaches 20%.

  2. What leak rate threshold applies to industrial process refrigeration appliances?

    Answer: 30%

    Industrial process refrigeration has a 30% trigger because those systems are larger and more complex.

  3. Within how many days of discovering a leak above the threshold must repairs normally be completed?

    Answer: 30 days

    Repairs are generally required within 30 days of discovering the leak rate exceeds the threshold.

  4. The leak repair requirements apply to appliances containing how much refrigerant?

    Answer: 50 lbs or more

    The requirements cover appliances with a refrigerant charge of 50 lbs or more.

  5. A commercial refrigeration system with a 100 lb charge has 25 lbs added over 12 months. What is the leak rate and is repair required?

    Answer: 25%, repair required

    25 lbs divided by 100 lbs is 25%, which exceeds the 20% commercial refrigeration threshold.

  6. When must the follow-up verification test be performed after a leak repair?

    Answer: After the system returns to normal operating conditions

    The follow-up test is done once the system has returned to normal operating characteristics and conditions.

  7. If a leak cannot be repaired within the required period, how long does the owner have to complete a retrofit or retirement plan after the plan is developed?

    Answer: 1 year

    The retrofit or retirement must be completed within one year of the plan's date.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ecfr.gov — Exam format, test delivery, fees, passing score, retake policy, score release · verified Oct 2026
  2. epa.gov — Test delivery, eligibility, renewal, score validity · verified Oct 2026