← All EPA 608 Flashcard Decks

Best Practices & Methodologies Flashcards

7 cards from real EPA 608 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Best Practices & Methodologies flashcards as text
  1. Which of the following is considered a prohibited practice under Section 608?

    Answer: Intentionally venting refrigerant while servicing

    Knowingly venting refrigerant is prohibited, apart from certain minimal releases.

  2. Which type of refrigerant has the highest ozone depletion potential among these?

    Answer: CFC-12

    CFCs such as CFC-12 have the highest ODP, while HFCs contain no chlorine.

  3. What should a technician do before transporting a recovery cylinder?

    Answer: Check DOT markings and the hydrostatic test date

    Cylinders must be DOT-approved and within the hydrostatic test date for safe transport.

  4. What is the correct action for a technician working in an enclosed machinery room with a large refrigerant leak?

    Answer: Evacuate and ventilate the area before reentering with proper protection

    Refrigerant displaces oxygen, so people should leave and the room be ventilated before work resumes with protective equipment.

  5. A recovery machine is being used on a system containing a different refrigerant than the previous job. What is best practice?

    Answer: Clean or purge the recovery machine to prevent cross-contamination

    Recovery equipment should be cleared of previous refrigerant to avoid mixing, which can make the refrigerant unusable.

  6. When is a technician NOT required to recover refrigerant before opening an appliance?

    Answer: Never; recovery or evacuation to the required level is always required unless an exemption applies

    Recovery to required levels is mandatory before opening the system, apart from specific exemptions.

  7. What does the term 'reclaim' mean in refrigerant handling?

    Answer: Processing refrigerant to virgin product specifications, verified by chemical analysis

    Reclaiming restores refrigerant to AHRI 700 purity, verified by lab analysis, and is done at EPA-certified reclaimers.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ecfr.gov — Exam format, test delivery, fees, passing score, retake policy, score release · verified Oct 2026
  2. epa.gov — Test delivery, eligibility, renewal, score validity · verified Oct 2026