  1. What causes a halide torch to change flame color when detecting chlorine-containing refrigerant leaks? Combustion of chlorine compounds producing copper chloride
  2. A high-pressure appliance with 210 pounds of R-407C refrigerant must be evacuated (recovered) to a level of; 10 inches of vacuum
  3. A refrigerant recovery cylinder used for mixed/contaminated refrigerant should be labeled and: Sent to a reclaimer or for destruction
  4. Which refrigerant was used in most vehicles built before 1994? R-12
  5. Which of the following gases is used in leak detection? HCFC-22
  6. Recovery equipment for R-134a is governed by which SAE standard? SAE J2210
  7. In a refrigeration cycle, which component raises the refrigerant's pressure and temperature? Compressor
  8. What document or record should a shop keep regarding refrigerant purchases and certified technicians? Proof of technician certification and refrigerant sales records
  9. What does the term 'azeotropic blend' mean when referring to refrigerants? A mixture that behaves like a single refrigerant with a constant boiling point
  10. Using a recovery cylinder that already contains refrigerant from a different system is acceptable only if: It is the same refrigerant type and the 80% fill limit is observed
  11. All refrigerated recovery cylinders are approved by this agency: DOT
  12. What color is the high-pressure (liquid line) side gauge on a typical manifold gauge set? Red
  13. Records of refrigerant recovered from appliances being disposed of should be kept to demonstrate what? Regulatory compliance
  14. Section 609 certification is specifically required for technicians who do what? Service or repair MVAC systems for consideration
  15. What safety device is required on the high side of a refrigeration system to protect against dangerously high pressures? Pressure-relief valve or rupture disc
  16. What is the standard color code for a refrigerant recovery cylinder? Gray with yellow top
  17. When charging an MVAC system, the correct refrigerant amount is determined by what? The vehicle manufacturer's specification
  18. What is the maximum allowable leak rate for comfort cooling equipment with a full charge of 50 or more pounds before repair is required under EPA Section 608? 10% per year
  19. Before opening a high-pressure system for service, the refrigerant should be recovered to what level for a system with an open compressor? 4 inches of vacuum
  20. Failure to be properly certified when servicing covered equipment can result in what? EPA fines and penalties
  21. A refrigerant identifier is used primarily to detect: The purity and type of refrigerant in a system
  22. What color designates R-410A refrigerant cylinders under ASHRAE standards? Rose/Pink
  23. CFCs are thought to have a lifespan of _____ years. 20 to 100
  24. What international agreement set the schedule for phasing out ozone-depleting substances? Montreal Protocol
  25. When a zeotropic refrigerant blend leaks significantly from a system, what is the correct service procedure? Recover the remaining charge and recharge with a full cylinder of fresh refrigerant
  26. Which atmospheric layer contains the ozone that protects life from harmful ultraviolet radiation? Stratosphere
  27. On a daily basis, which of the following should be verified in refrigerant recovery equipment? Both Oil Levels and for Refrigerant Leaks
  28. Ozone is a harmful pollutant on the ground and in the stratosphere. A) False
  29. Before opening a low-pressure appliance for service, the technician must first: Recover the refrigerant to the required level
  30. What is the approximate 100-year Global Warming Potential (GWP) of R-410A? 2,088