โ† All CTC Flashcard Decks

Data Acquisition and Validation Flashcards

7 cards from real CTC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Data Acquisition and Validation flashcards as text
  1. Which type of transducer converts mechanical strain into an electrical signal for data acquisition?

    Answer: Strain gauge

    A strain gauge changes electrical resistance proportional to the mechanical deformation applied to it.

  2. What is the primary purpose of anti-aliasing filters in a data acquisition system?

    Answer: Remove frequencies above the Nyquist limit before sampling

    Anti-aliasing filters attenuate signal components above half the sample rate to prevent aliasing artifacts in the digitized data.

  3. A PCM (Pulse Code Modulation) stream is used in flight test telemetry primarily to:

    Answer: Multiplex multiple analog channels into a single digital bit stream

    PCM time-division multiplexing encodes multiple channels sequentially into one digital stream for efficient telemetry transmission.

  4. Which validation technique compares measured data against a known reference standard to confirm sensor accuracy?

    Answer: Calibration check

    Calibration checks verify that sensor output matches a known reference standard within specified accuracy tolerances.

  5. In flight test data acquisition, 'frame synchronization' refers to:

    Answer: Identifying the correct starting point of a PCM frame in the bit stream

    Frame synchronization detects the unique sync word pattern that marks the beginning of each PCM data frame.

  6. What does 'measurement uncertainty' quantify in a test data context?

    Answer: The range within which the true value of a measurement is expected to lie

    Measurement uncertainty expresses the statistical range encompassing the true value of a measured quantity at a stated confidence level.

  7. A data acquisition system records a parameter at 200 samples per second. What is the highest frequency that can be accurately captured without aliasing?

    Answer: 100 Hz

    By the Nyquist theorem, the maximum unambiguous frequency is half the sample rate, so 200 sps captures up to 100 Hz accurately.

How this page was made: written with AI tools. We have not yet matched this exam's facts to an official source, so confirm fees, dates and rules with the exam body. Not reviewed by a subject-matter expert. Editorial policy