Non-Sterile to Sterile Compounding Flashcards
7 cards from real CSPT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Non-Sterile to Sterile Compounding flashcards as text
When converting a non-sterile bulk powder to a sterile injectable, which sterilization method is preferred for heat-stable compounds?
Answer: Autoclaving (moist heat sterilization)
Autoclaving (moist heat) at 121°C for at least 15 minutes is the preferred terminal sterilization method for heat-stable compounded sterile preparations.
A pharmacist determines that a non-sterile API cannot withstand heat sterilization. Which alternative sterilization method should be used?
Answer: Sterile filtration through a 0.22 µm filter
Sterile filtration through a 0.22 µm (or smaller) membrane filter is the standard alternative sterilization method for heat-labile compounds.
Which documentation must be completed BEFORE beginning a non-sterile to sterile compounding process?
Answer: Master formulation record review and compounding record initiation
The master formulation record must be reviewed and a compounding record initiated prior to starting any compounding process to ensure accuracy and traceability.
What is the primary purpose of conducting a filter integrity test (bubble point test) after sterile filtration?
Answer: To verify the filter membrane was not compromised during filtration
A post-filtration bubble point test confirms the filter membrane remained intact and was not ruptured, ensuring the filtration achieved sterilization.
When dissolving a non-sterile powder for subsequent sterile filtration, which quality attribute of the solvent is critical?
Answer: The solvent must be sterile-grade or Water for Injection (WFI)
Sterile-grade solvents or Water for Injection must be used to minimize bioburden before final 0.22 µm sterile filtration.
A compounding technician is preparing a sterile ophthalmic solution from a non-sterile API. What tonicity adjustment is typically required?
Answer: The preparation should be isotonic (approximately 0.9% NaCl equivalent)
Ophthalmic preparations should be isotonic (equivalent to 0.9% NaCl) to prevent irritation and maintain patient comfort.
Under USP , which category of compounded sterile preparations (CSPs) requires the most stringent environmental monitoring and testing?
Answer: Category 2 CSPs intended for longer storage periods
Category 2 CSPs, which are assigned longer beyond-use dates, require the most stringent environmental monitoring, personnel qualification, and quality testing under USP .
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- ptcb.org — Late registration, registration deadline, renewal, test delivery, eligibility, fees, exam format, passing score, score release, test dates · verified Oct 2026
- myaccount.ptcb.org — Retake fee, retake policy · verified Oct 2026