According to USP , what is the maximum permitted total particle count (≥0.5 µm) per cubic meter in an ISO Class 5 primary engineering control (PEC)?
Answer: 3,520 particles/m³
ISO Class 5 (the classification required for PECs such as laminar airflow workbenches and BSCs) allows no more than 3,520 particles ≥0.5 µm per cubic meter.
Which type of sampling device is used to actively collect airborne viable microorganisms for environmental monitoring in a sterile compounding facility?
Answer: Active air sampler (impaction sampler)
Active air samplers (e.g., RCS or SAS impaction samplers) draw a known volume of air through the device to quantitatively collect viable particles, providing a volumetric CFU count.
A settle plate (passive air sampling) is exposed in a cleanroom. According to USP , how long should a settle plate be exposed to obtain a valid sample in a PEC?
Answer: 1 hour
USP specifies that settle plates should be exposed for no longer than 4 hours, but a standard exposure of 1 hour is typical in ISO Class 5 PECs to obtain meaningful passive air monitoring data.
What is the action level for viable surface sampling (contact plates) in an ISO Class 5 PEC, expressed in CFU per contact plate (25 cm²)?
Answer: 0 CFU
USP sets the action level for ISO Class 5 surfaces at >0 CFU (i.e., any growth triggers an investigation), because the PEC must be essentially sterile to protect compounded preparations.
Which test is performed to verify that a laminar airflow workbench (LAFW) meets ISO Class 5 air quality requirements and that the HEPA filter is intact?
Answer: DOP/PAO (dispersed oil particulate) aerosol challenge test
DOP or PAO aerosol challenge testing introduces a standardized aerosol upstream of the HEPA filter and measures downstream penetration to verify filter integrity and proper sealing.
How frequently must viable environmental monitoring (both air and surface) be performed in ISO Class 5 and ISO Class 7 areas of a Category 2 CSP compounding operation per USP ?
Answer: Monthly
USP requires that viable environmental monitoring of ISO Class 5 and ISO Class 7 areas in Category 2 operations be conducted at least monthly under dynamic (in-use) conditions.
When environmental monitoring results exceed established action levels in a sterile compounding cleanroom, what is the FIRST required step?
Answer: Identify the source of contamination and perform corrective action before resuming compounding
The first mandatory step when action levels are exceeded is to identify the contamination source and implement corrective actions (re-cleaning, re-training, equipment inspection) before compounding can safely resume.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- ptcb.org — Late registration, registration deadline, renewal, test delivery, eligibility, fees, exam format, passing score, score release, test dates · verified Oct 2026
- myaccount.ptcb.org — Retake fee, retake policy · verified Oct 2026