← All CSPT Flashcard Decks

Sterilization Methods and Filtration Technology Flashcards

6 cards from real CSPT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Sterilization Methods and Filtration Technology flashcards as text
  1. What is the minimum membrane filter pore size required to achieve sterilization by filtration of a compounded sterile preparation?

    Answer: 0.22 micron

    A pore size of ≤0.22 micron (also stated as 0.2 micron) is required for sterilizing-grade filtration because it retains bacteria. Larger pore sizes (0.45 micron) are used for clarification, not sterilization.

  2. What are the standard parameters for terminal sterilization of a preparation by moist heat (autoclave)?

    Answer: 121°C for a minimum of 15 minutes at 15 psi

    The standard autoclave cycle is 121°C at 15 psi for at least 15 minutes. This combination of temperature and pressure is sufficient to achieve a sterility assurance level (SAL) of 10⁻⁶ for terminally sterilized preparations.

  3. Which sterilization method is MOST appropriate for a heat-sensitive aqueous drug that cannot withstand autoclave temperatures?

    Answer: Membrane filtration through a 0.22-micron sterilizing-grade filter

    Membrane filtration through a ≤0.22-micron filter is the preferred method for heat-sensitive aqueous preparations. It removes bacteria and fungi without exposing the drug to destructive temperatures. Ethylene oxide is used for devices, and dry heat/radiation are not practical for liquids.

  4. What is 'depyrogenation,' and which method is most commonly used to achieve it on glassware and equipment?

    Answer: Removal of endotoxins; dry heat at ≥250°C for at least 30 minutes

    Depyrogenation is the destruction or removal of pyrogens (primarily bacterial endotoxins). Endotoxins are heat-stable and survive standard autoclaving; dry heat at ≥250°C for ≥30 minutes is required to destroy them on glassware and stainless steel.

  5. After filtering a compounded sterile preparation through a 0.22-micron membrane filter, a bubble point integrity test is performed. What does this test confirm?

    Answer: That the filter membrane is intact and was not compromised during filtration

    The bubble point integrity test verifies that the filter membrane has not been punctured, torn, or otherwise compromised. A breached filter could allow microorganisms to pass through, invalidating the sterilization process. USP requires post-filtration integrity testing for high-risk CSPs.

  6. Which of the following BEST describes 'terminal sterilization' as opposed to 'aseptic processing'?

    Answer: Sterilizing the final sealed container after filling to achieve a defined sterility assurance level

    Terminal sterilization involves sterilizing the product after it has been filled and sealed in its final container (e.g., autoclaving a sealed vial). This is contrasted with aseptic processing, where sterile components are combined under aseptic conditions but the final container is never subjected to a sterilization step.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ptcb.org — Late registration, registration deadline, renewal, test delivery, eligibility, fees, exam format, passing score, score release, test dates · verified Oct 2026
  2. myaccount.ptcb.org — Retake fee, retake policy · verified Oct 2026
Sterilization Methods and Filtration Technology Flashcards — CSPT Study Cards with Answers