Residential Energy Efficiency & Load Calculations Flashcards
7 cards from real CRD practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Residential Energy Efficiency & Load Calculations flashcards as text
Which method is most commonly used for residential cooling load calculations in geothermal system design per ACCA standards?
Answer: Manual J
Manual J by ACCA is the industry-standard residential load calculation method used to size geothermal and other HVAC systems.
A house has a design heating load of 48,000 BTU/hr. If a geothermal heat pump has a COP of 3.5, what is the approximate electrical input required?
Answer: 13,714 BTU/hr (4.02 kW)
Electrical input = 48,000 / 3.5 ≈ 13,714 BTU/hr; dividing by 3,412 BTU/kWh gives approximately 4.02 kW.
In residential load calculations, infiltration is typically measured using which unit?
Answer: ACH (air changes per hour)
Infiltration in residential buildings is expressed as ACH (air changes per hour), representing how many times the home's air volume is replaced by outdoor air.
Which insulation metric directly describes how well a material resists heat flow per inch of thickness?
Answer: R-value per inch
R-value per inch (specific R-value) describes a material's thermal resistance per unit thickness, enabling comparison between insulation types.
The Design Temperature Difference (DTD) used in heat loss calculations is defined as:
Answer: Indoor design temperature minus the outdoor design dry-bulb temperature
DTD = indoor setpoint (typically 70°F) minus the outdoor winter design temperature, representing the worst-case temperature difference driving heat loss.
For geothermal system sizing, the peak cooling load is most influenced by:
Answer: Solar heat gain through windows and roof
Solar heat gain through glazing and roofing materials is typically the dominant driver of residential peak cooling loads in summer.
Which building code energy standard sets minimum envelope efficiency requirements that directly affect geothermal system sizing?
Answer: IECC (International Energy Conservation Code)
IECC establishes minimum insulation, window, and air sealing requirements for residential buildings, directly reducing the loads that geothermal systems must meet.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- igshpa.org — Renewal, fees, eligibility, score validity · verified Oct 2026
- csagroup.org — Test delivery, exam format, passing score, renewal, retake policy, score release, time limit, score validity · verified Oct 2026