  1. During a thermal response test (TRT), what two key ground parameters are determined?

    Answer: Ground thermal conductivity and borehole thermal resistance

    A TRT injects or extracts heat at a known rate and measures temperature response over time to calculate ground thermal conductivity and borehole thermal resistance.

  2. A header manifold in a parallel ground loop field is sized primarily to:

    Answer: Ensure equal flow distribution to all parallel bore circuits

    Proper manifold sizing and reverse-return or balanced-tee design ensures equal flow through each bore, preventing short-circuiting of cooler or warmer fluid.

  3. What is 'undisturbed ground temperature' (UGT) and why is it critical in loop design?

    Answer: The native soil temperature before system installation, representing the baseline for heat exchange calculations

    UGT is the soil temperature before any system influence; it sets the source/sink baseline that determines heat pump COP and required bore length.

  4. Which of the following best describes the 'EWT' that appears on a heat pump performance data table?

    Answer: Entering water temperature to the heat pump from the ground loop

    EWT (Entering Water Temperature) is the ground loop fluid temperature entering the heat pump's water-to-refrigerant heat exchanger, directly affecting rated capacity and efficiency.

  5. What happens to heat pump heating COP as entering water temperature (EWT) decreases during cold winters?

    Answer: COP decreases because the temperature lift the compressor must overcome increases

    Lower EWT means the refrigerant must evaporate at a lower pressure, increasing compressor compression ratio and work input, thereby reducing COP.

  6. In a hybrid geothermal system, a supplemental cooling tower is added primarily to:

    Answer: Reject excess heat during cooling-dominated operation to reduce ground temperature rise

    A cooling tower dissipates excess heat rejection in cooling-dominated climates, preventing long-term ground warming that would degrade heat pump COP over years.

  7. Which design tool calculation method does ASHRAE recommend for sizing vertical bore fields in commercial and residential applications?

    Answer: The g-function method using dimensionless borehole response functions

    ASHRAE and IGSHPA recommend the g-function (Eskilson) method, which uses borehole response functions to account for thermal interference and long-term ground temperature changes.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. igshpa.org — Renewal, fees, eligibility, score validity · verified Oct 2026
  2. csagroup.org — Test delivery, exam format, passing score, renewal, retake policy, score release, time limit, score validity · verified Oct 2026