← All CPG Flashcard Decks

Specimen Collection & Handling Flashcards

7 cards from real CPG practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Specimen Collection & Handling flashcards as text
  1. During low-flow (minimal drawdown) groundwater purging, when is the well generally considered ready to sample?

    Answer: When field parameters such as pH, conductivity, temperature, DO, and ORP stabilize within set criteria

    Low-flow protocols rely on stabilization of indicator parameters over consecutive readings, not a fixed purge volume.

  2. An equipment rinsate blank is collected mainly to evaluate which of the following?

    Answer: How well non-dedicated sampling equipment was decontaminated

    Analyte-free water poured over or through decontaminated equipment shows whether cross-contamination could come from reused gear.

  3. A geologist collects a field duplicate. What does comparing the duplicate with its parent sample mainly assess?

    Answer: Precision of the combined sampling and analytical process

    Field duplicates are evaluated by relative percent difference to measure overall precision, including sampling variability.

  4. When logging a split-spoon sample, the blow counts for the second and third 6-inch increments are added together to report what?

    Answer: Standard Penetration Test N-value

    Under ASTM D1586, the N-value is the sum of blows for the last two 6-inch increments of an 18-inch drive.

  5. Why are samples for VOC analysis in water collected in 40-mL vials with no headspace?

    Answer: To prevent volatile compounds from partitioning into trapped air and escaping

    Any air bubble lets VOCs partition out of the water, so vials are filled to a convex meniscus and checked for bubbles.

  6. What is the typical preservative for water samples analyzed for VOCs by EPA Method 8260?

    Answer: Hydrochloric acid to pH below 2 and cooling

    HCl acidification slows biodegradation of aromatic VOCs, and cooling to 6°C or below extends the holding time to 14 days.

  7. Rock Quality Designation (RQD) is calculated using which core pieces?

    Answer: Only intact core pieces 4 inches (10 cm) or longer, as a percent of the run length

    RQD sums sound core pieces at least 10 cm long and divides by the total core run length.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. aipg.org — Score release, eligibility, fees, renewal, test delivery · verified Oct 2026