CPC Building Codes, Permits & Inspections Flashcards
6 cards from real CPC practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 CPC Building Codes, Permits & Inspections flashcards as text
What is the purpose of an 'energy code compliance report' required for new commercial buildings?
Answer: Demonstrate that the building envelope, mechanical, and lighting systems meet minimum energy efficiency requirements of IECC or ASHRAE 90.1
Energy code compliance (required by IECC or ASHRAE 90.1) documents that the building's envelope, HVAC, lighting, and service water heating systems achieve minimum energy performance.
Under the IBC, when is a building required to have an automatic fire sprinkler system?
Answer: Based on occupancy type, construction type, height, and area — often required for all new commercial buildings under IBC Section 903
IBC Section 903 requires sprinklers based on occupancy (e.g., all Group A over 300 occupants, all R occupancies), height (high-rises), and area thresholds that vary by building type.
What is a 'stop work order' and what authority can issue one on a construction site?
Answer: An official directive to halt construction activity due to code violations, safety hazards, or permit non-compliance; issued by building officials or OSHA
Stop work orders are legal directives issued by authorized government officials (building department, OSHA, EPA) requiring all or specific construction activities to cease until violations are corrected.
In a fire-rated wall assembly, what is the purpose of 'firestopping' at penetrations?
Answer: Seal openings where pipes, conduits, and ducts penetrate fire-rated assemblies to prevent fire and smoke spread
Firestopping materials (intumescent, caulk, putty, mineral wool) are used to seal all penetrations in fire-rated assemblies to restore the assembly's rated fire resistance.
What is a 'punch list' in the context of project closeout and inspections?
Answer: A documented list of incomplete or defective work items that must be corrected before final acceptance
A punch list is developed during substantial completion walk-throughs and itemizes work that must be finished or repaired before final acceptance and release of retainage.
Which accessibility code standard provides the technical specifications that states and local governments adopt for accessible construction?
Answer: ADA Standards for Accessible Design (based on ICC/ANSI A117.1)
The ADA Standards for Accessible Design, based on ICC/ANSI A117.1, provide the detailed technical criteria (slopes, widths, reach ranges, clearances) for all accessible elements.