Which regulatory body in the United States sets occupational radiation dose limits for CT technologists?
Answer: Nuclear Regulatory Commission (NRC)
The NRC sets the annual occupational whole-body dose limit of 50 mSv (5 rem) for radiation workers in the US, including CT technologists.
Which artifact appears as dark streaks in a CT image, often caused by dense structures like bones?
Answer: Streak artifact
Streak artifacts are characterized by dark lines or bands that appear across a CT image, often originating from highly attenuating objects. While beam hardening is a common cause of streaks, especially from dense bone, the general term for these linear obscurations is "streak artifact." Metallic objects also cause severe streak artifacts due to their high attenuation and beam hardening effects.
What does the term "windowing" refer to in CT image analysis?
Answer: Changing the display brightness and contrast
Windowing in CT imaging refers to the process of adjusting the range of Hounsfield units (CT numbers) displayed on the monitor, which directly controls the brightness (window level) and contrast (window width) of the image. This allows radiologists to optimize the visualization of specific tissue types, such as bone, soft tissue, or lung, by highlighting their particular density ranges. It's a crucial post-processing technique for diagnostic interpretation.
A non-contrast CT brain in a neonate with seizures reveals periventricular calcifications. The most likely causative infection is:
Answer: Cytomegalovirus (CMV)
Congenital CMV classically produces periventricular calcifications on CT, along with microcephaly and cortical malformations.
In CT, increasing the field of view (FOV) while keeping matrix size constant will have what effect on voxel size?
Answer: Voxel size increases, reducing spatial resolution
Voxel size = FOV / matrix size; a larger FOV with the same matrix produces larger voxels, lowering spatial resolution.
A CT brain shows a well-defined, homogeneously hyperdense extra-axial mass that broadly attaches to the inner table of the skull and causes hyperostosis of the adjacent bone. This is most consistent with:
Answer: Meningioma
Meningiomas are characteristically hyperdense on non-contrast CT, show homogeneous enhancement, have a dural base, and frequently cause adjacent bony hyperostosis.
What is the term for the minimum detectable difference in attenuation between two adjacent structures in CT?
Answer: Contrast resolution
Contrast resolution refers to the ability to distinguish between tissues with similar attenuation values, and it is primarily affected by noise and radiation dose.
Which parameter is adjusted by the kilovoltage (kV) setting in CT scanning?
Answer: Radiation dose
The kilovoltage (kV) setting in CT scanning determines the energy and penetrating power of the X-ray beam. A higher kV setting means the X-rays are more energetic and penetrate tissues more effectively, but it also directly increases the amount of radiation absorbed by the patient. Therefore, kV is a primary parameter for adjusting the radiation dose.
What is the primary purpose of using automatic exposure control (AEC) in CT?
Answer: Adapt tube current to patient size and anatomy
AEC (also called tube current modulation) automatically adjusts mA based on patient attenuation to optimize image quality while minimizing dose.
Which type of contrast medium is often used in CT imaging to enhance visualization of blood vessels and other structures?
Answer: Iodine-based
A Hounsfield Unit (HU) is a quantitative scale used in CT imaging to measure the radiodensity of tissues. It is a standardized unit that relates the attenuation coefficient of a tissue to that of water, which is assigned a value of 0 HU. Different tissues have characteristic HU values, allowing radiologists to differentiate between structures like bone, soft tissue, fat, and air.
Quantum noise (mottle) in CT images is primarily caused by:
Answer: Insufficient number of X-ray photons reaching the detectors
Quantum noise results from statistical fluctuations in photon detection; when too few photons reach the detector (low mAs or large patient), random variations appear as image noise.
Which factor influences the spatial resolution of a CT scan?
Answer: Slice thickness
Spatial resolution refers to a CT scan's ability to distinguish between two closely spaced objects. Slice thickness directly influences the resolution along the z-axis (the patient's long axis). Thinner slices provide finer detail and better separation of structures in the axial plane, thereby improving the overall spatial resolution. This allows for clearer visualization of small anatomical features and subtle abnormalities.
What is the purpose of CT dose modulation techniques?
Answer: To optimize radiation exposure
CT dose modulation techniques are advanced features designed to automatically adjust the X-ray tube current (mAs) during a scan based on the patient's anatomy. By reducing the dose in thinner or less attenuating regions and increasing it in thicker or denser areas, these techniques optimize radiation exposure. This maintains image quality while significantly reducing the overall patient dose.
At what injection rate (mL/sec) is intravenous contrast typically administered for a CT pulmonary angiography (CTPA)?
Answer: 3–5 mL/sec
CTPA requires a brisk injection rate of 3–5 mL/sec to achieve adequate pulmonary artery opacification during the brief arterial phase.
What is the primary purpose of CT fluoroscopy?
Answer: To monitor needle guidance during procedures
CT fluoroscopy provides real-time CT images, similar to conventional fluoroscopy but with cross-sectional views. Its primary purpose is to guide interventional procedures, such as biopsies, drainages, and pain injections, by allowing the operator to continuously monitor the advancement of a needle or catheter. This real-time visualization significantly improves accuracy and safety during these procedures.
What type of adverse reaction to iodinated contrast media involves an immune-mediated hypersensitivity response?
Answer: Anaphylactoid (allergy-like) reaction
Anaphylactoid reactions mimic true anaphylaxis (urticaria, bronchospasm, hypotension) but do not require prior sensitization and are not IgE-mediated.
The patient should be questioned about the following matters before receiving an intravenous injection of iodinated contrast material: 1. Renal Function- One kidney dose is cut 2. Allergic History- Premedicated 3. Cardiac History- Heart disease
Answer: 1,2, and 3
Before administering iodinated contrast material, it is crucial to assess the patient's renal function, as the kidneys excrete the contrast, and impairment can lead to contrast-induced nephropathy. An allergic history is vital to identify potential hypersensitivity reactions to iodine, which can range from mild to severe. Cardiac history is also important because contrast media can affect heart function, especially in patients with pre-existing cardiac conditions, increasing the risk of adverse events.
CT colonography (virtual colonoscopy) is performed with the patient in which position to evaluate both the colon positions?
Answer: Both supine and prone positions
Both supine and prone acquisitions are standard for CT colonography; repositioning redistributes residual fluid and stool, allowing evaluation of dependent and non-dependent colonic segments.
Which reconstruction algorithm produces the sharpest bone detail in CT imaging?
Answer: High-frequency (edge-enhancing) kernel
High-frequency or bone kernels accentuate edge transitions, producing sharper images ideal for cortical bone and temporal bone detail, though they increase image noise.
Which organ is typically used as a reference when setting window level for abdominal CT?
Answer: Liver
The liver is commonly used as the window level reference in abdominal CT because it has a consistent, predictable attenuation value of approximately 50-70 HU.
Written and edited by Nathan Beja, founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- assets-us-01.kc-usercontent.com — Test dates · verified Nov 2026
- arrt.org — Retake policy, passing score, score release, fees, renewal, retake fee, eligibility, test delivery · verified Nov 2026