← All CMM Flashcard Decks

Building Systems Operations & Maintenance Flashcards

7 cards from real CMM practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Building Systems Operations & Maintenance flashcards as text
  1. Which NFPA standard governs the inspection, testing, and maintenance of water-based fire protection systems such as sprinklers and fire pumps?

    Answer: NFPA 25

    NFPA 25 covers ongoing ITM of water-based systems, while NFPA 13 covers their installation.

  2. Which NFPA document addresses maintenance programs for electrical equipment such as switchgear, transformers, and panelboards?

    Answer: NFPA 70B

    NFPA 70B is the standard for electrical equipment maintenance, while 70E covers electrical safety in the workplace.

  3. What is the main purpose of infrared thermography surveys of electrical distribution equipment?

    Answer: Detect hot spots from loose connections or overloaded components

    Thermography identifies abnormal heat caused by high resistance or overload before a failure occurs.

  4. Under NFPA 110, how should a Level 1 emergency generator be exercised each month?

    Answer: Run under load for at least 30 minutes

    NFPA 110 requires monthly exercise under load for a minimum of 30 minutes under specified loading conditions.

  5. Which standard sets requirements for arc flash risk assessment, PPE, and warning labels on electrical equipment?

    Answer: NFPA 70E

    NFPA 70E, Standard for Electrical Safety in the Workplace, governs arc flash hazard analysis and PPE.

  6. Per NFPA 101, battery-powered emergency lighting must receive which tests?

    Answer: A 30-second monthly functional test and a 90-minute annual test

    The Life Safety Code requires monthly 30-second tests and an annual 1.5-hour duration test.

  7. A Class A GFCI receptacle is designed to trip when ground-fault current reaches approximately what level?

    Answer: 5 milliamperes

    Class A GFCIs trip at 4 to 6 mA to protect people from electric shock.

How this page was made: written with AI tools. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. learn.nahro.org — Eligibility, fees, score validity · verified Oct 2026
  2. nahro.org — Renewal, retake policy · verified Oct 2026