CLD Cheat Sheet 2026
The 30 highest-yield CLD facts, distilled from real exam questions. Print it, save it as a PDF, or study it here β free, no sign-up.
30 questions
60 min time limit
50.00% to pass
- Which end-of-life concern is unique to fluorescent lamps compared to LED luminaires in sustainability planning? β Mercury content requiring RCRA hazardous waste handling
- Which professional attribute is most valued in lighting fundamentals within the CLD field? β Accountability and commitment to standards
- Which LEED v4 credit requires spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE) as the primary simulation metrics? β IEQ Credit: Daylight
- Which approach best demonstrates mastery of controls and dimming in CLD practice? β Applying principles to novel situations with sound judgment
- Which IES standard provides guidelines for energy-efficient exterior roadway and area lighting? β IES RP-8
- When a jurisdiction adopts the 2021 IECC, which lighting control is typically required for all interior spaces greater than 5,000 ftΒ²? β Automatic shutoff controls
- Maintained illuminance refers to: β The average illuminance level at which maintenance should be performed
- Luminous intensity is measured in which unit? β Candela
- What is the spectral power distribution (SPD) of a light source? β A graph showing radiant power emitted at each wavelength across the visible spectrum
- Which type of occupancy sensor technology is best suited for detecting minor motion in large open-plan offices? β Dual-technology (PIR + ultrasonic)
- What is the best practice for maintaining daylighting design performance over time? β Implement scheduled preventive maintenance
- A museum replaces fiber optic display lighting with LED. What is the primary sustainability advantage beyond energy savings? β LEDs emit no UV or IR radiation, eliminating the need for UV filters that become waste
- Which NFPA standard governs the installation and performance of emergency and standby power systems that supply egress lighting? β NFPA 110
- Which dimming protocol uses a two-wire digital bus to individually address up to 64 devices per segment? β DALI
- IES TM-21 is used in conjunction with LM-80 test data to accomplish what? β Project long-term LED lumen maintenance beyond the tested period
- A south-facing clerestory window primarily delivers daylight to which area of a room? β The deeper interior zones away from the primary faΓ§ade
- ASHRAE 90.1 requires automatic shutoff controls for interior lighting in spaces larger than what square footage threshold? β 2,500 sq ft
- What is the primary function of a 0β10 V dimming signal? β Lowβvoltage DC dimming control
- Under NFPA 70 (National Electrical Code), outdoor luminaires installed in wet locations must be listed and labeled for: β 'Wet location' use
- What does the term 'efficacy' mean when applied to a light source? β The ratio of luminous flux output to electrical power input, expressed in lumens per watt
- Which section of the International Building Code (IBC) primarily governs means-of-egress lighting levels? β Section 1008
- When planning a project in Certified Lighting Designer, which element should be established FIRST? β Clear objectives, scope, and success criteria
- Which US federal regulation sets minimum efficacy standards for general service lamps sold in the country, complementing building energy codes? β DOE Lamp Rule under EPCA
- Which approach best demonstrates mastery of energy codes in CLD practice? β Applying principles to novel situations with sound judgment
- Which protocol allows lighting systems to communicate energy data to building management systems for sustainability monitoring? β BACnet
- A restaurant designer wants to create a candlelight effect using electric lighting. Which combination of luminaire characteristics best achieves this? β Low-lumen 1800Kβ2200K sources with warm-dim capability
- In ASHRAE 90.1, what is the primary compliance pathway for interior lighting energy in a commercial building? β Lighting Power Density (LPD) limits
- A designer calculates Annual Energy Use Intensity (EUI) for lighting. Which unit is correct? β kBtu/ftΒ²/year
- A lighting designer specifies luminaires with a Unified Glare Rating (UGR) below 19. What sustainability co-benefit does this primarily provide? β Improved occupant visual comfort and productivity
- A hospital corridor is lit to 30 fc for normal operation and automatically steps down to 5 fc when unoccupied at night. This strategy is best described as: β Bi-level switching