CIS Study Guide 2026

Everything you need to pass the CIS exam in one place: the exam format, every topic to study, real practice questions with explanations, flashcards, and full-length practice tests. Free, no sign-up needed.

📋 CIS Exam Format at a Glance

100
Questions
150 min
Time Limit
70.00%
Passing Score

📚 CIS Topics to Study (38)

✍️ Sample CIS Questions & Answers

1. The most common lead-free solder alloy used in SMT reflow soldering per J-STD-006 is:
✓ SAC305 (Sn96.5/Ag3.0/Cu0.5)

SAC305 (96.5% tin, 3% silver, 0.5% copper) is the industry-standard lead-free alloy with a melting point of approximately 217–221°C.

2. Which cleanliness test method measures ionic contamination on a PCB assembly after soldering?
✓ ROSE (Resistivity of Solvent Extract) test

The ROSE test (also known as the Omega-meter test) measures ionic contamination by dissolving surface residues in isopropyl alcohol/water and measuring resistivity change.

3. What is 'pad conditioning' during SMT rework?
✓ Cleaning, re-tinning, or reshaping the solder pad to its proper form before installing a replacement component

Pad conditioning involves cleaning residual solder from the pad, re-tinning with fresh solder if needed, and verifying the pad shape and condition before installing a replacement component.

4. An inspector observes a solder bridge between two adjacent SMD pads on a Class 2 assembly. Which of the following best describes the disposition?
✓ Defect — requires rework or rejection

Solder bridges between conductors that should not be electrically connected are unconditional defects under IPC-A-610 for all product classes.

5. When performing solderability testing per J-STD-003, what does the wetting balance test measure?
✓ The force exerted on a component lead as it is immersed in molten solder

The wetting balance (Meniscograph) test measures the time-force curve as a lead is immersed in solder, quantifying the speed and degree of solder wetting.

6. What hazard does halide contamination (chlorides, bromides) pose to PCB assemblies?
✓ Halides are aggressive activators that accelerate corrosion and electrochemical migration if not fully removed

Halide ions (Cl⁻, Br⁻) from flux activators are aggressive corrosion catalysts; if left on the assembly, they absorb moisture and create highly corrosive ionic solutions that accelerate metal corrosion and electrochemical migration.

🎯 Free CIS Practice Tests

📖 CIS Guides & Articles

Your CIS Study Path
1. Learn with Flashcards → 2. Drill Practice Tests → 3. Take the Full Exam Simulation
Was this helpful?