CHI Roofing Systems Inspection Flashcards

6 cards from real CHI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 CHI Roofing Systems Inspection flashcards as text
  1. When inspecting a wood shake roof, which condition indicates an immediate safety and weathertightness concern?

    Answer: Missing, split, or severely cupped shakes exposing the underlayment or sheathing

    Missing or severely damaged shakes leave the underlayment or deck boards exposed, creating direct pathways for water infiltration and potentially indicating widespread end-of-life deterioration.

  2. A home inspector finds that counter-flashing at a chimney is embedded in the mortar joints but is not sealed with caulk or sealant. Is this acceptable?

    Answer: Yes — properly tuck-pointed counter-flashing embedded in mortar is self-sealing and caulk is not required

    Counter-flashing that is properly embedded (regletted) into intact mortar joints forms a weather-tight seal without sealant; caulking is only required for surface-applied counter-flashing.

  3. What is the purpose of the 'drip edge' flashing installed at the eave and rake of a shingled roof?

    Answer: To direct water away from the fascia and prevent capillary wicking under the shingle edge

    Drip edge flashing projects water past the fascia board, preventing capillary action from pulling water back under the shingle overhang and causing rot to the fascia and soffit.

  4. During a roof inspection, the home inspector walks the surface and notices a spongy or soft feel underfoot in a localized area. What should the inspector conclude?

    Answer: The roof decking in that area is likely rotted or delaminated and requires further evaluation

    A soft or spongy area underfoot on a roof typically indicates that the sheathing has been damaged by water infiltration, leading to rot or delamination of the OSB or plywood deck.

  5. A home inspector observes that a previously repaired area on a low-slope EPDM roof has a lap seam that is lifting and not fully bonded. What is the correct assessment?

    Answer: This is a deficiency — open lap seams on EPDM roofs are a primary source of water infiltration

    Unbonded or lifting lap seams on EPDM roofing are a leading cause of membrane roof leaks, as water can easily wick under the open seam and enter the roof assembly.

  6. Which of the following statements correctly describes the inspection standard for a home inspector evaluating roof condition from the ground when walking the roof surface is not safe or possible?

    Answer: The inspector should use binoculars, drone, or other observation methods and clearly note the limitation in the report

    When a roof cannot be safely walked, inspectors use alternative observation methods such as binoculars or drones and are required to document the limitation and methods used in the inspection report.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. nationalhomeinspectorexam.org — Test delivery, fees, exam format, passing score, retake policy, test dates, time limit, exam information · verified Nov 2026
  2. test-takers.psiexams.com — Retake fee, score release, score validity · verified Nov 2026