← All CH Flashcard Decks

Acoustic Doppler & Velocity Measurement Flashcards

6 cards from real CH practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Acoustic Doppler & Velocity Measurement flashcards as text
  1. The 'moving bed' condition during ADCP measurements occurs when:

    Answer: Bedload sediment transport causes the bottom to appear to move relative to the instrument

    A moving bed condition exists when bedload sediment moves fast enough to bias bottom-tracking velocity estimates, causing apparent upstream vessel movement and discharge overestimation.

  2. Which test is performed to detect a moving bed condition during ADCP field measurements?

    Answer: Stationary moving bed test with vessel anchored or held fixed

    In the stationary moving bed test, the vessel is held stationary while the ADCP bottom tracks; any apparent displacement indicates bedload movement.

  3. In Doppler velocity measurement, the Nyquist velocity limit defines:

    Answer: The maximum unambiguous velocity measurable without phase aliasing

    The Nyquist limit is the maximum velocity the system can measure unambiguously; velocities exceeding it produce aliased (wrapped) readings that appear as opposite-sign velocities.

  4. What does the 'error velocity' output from a four-beam ADCP indicate?

    Answer: Inconsistency between redundant beam-pair velocity solutions, flagging data quality

    Error velocity is computed from the difference between the two independent estimates of vertical velocity from opposite beam pairs; large values flag acoustic interference or inhomogeneous flow.

  5. The speed of sound used by an ADCP to convert travel time to range is primarily a function of:

    Answer: Water temperature, salinity, and pressure (depth)

    Sound speed in water increases with temperature, salinity, and pressure; the ADCP uses a sound speed value (often from a sensor or default profile) to scale range calculations correctly.

  6. According to USGS Techniques and Methods 3-A22, the recommended minimum number of transects for a standard ADCP discharge measurement is:

    Answer: 4 transects

    USGS guidance recommends a minimum of four transects (two in each direction) to obtain a reliable mean discharge estimate and assess measurement repeatability.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. cdn.ymaws.com — Exam information · verified Oct 2026
  2. nsps.us.com — Test delivery, eligibility, fees, exam format, renewal, retake policy, test dates, time limit, score validity · verified Oct 2026
  3. thsoa.org — Exam dates · verified Oct 2026