  1. Which masonry product is acceptable below the BFE?

    Answer: Concrete masonry units (CMU)

    Concrete block and brick with appropriate mortar withstand prolonged flood contact.

  2. Which FEMA publication is the primary NFIP guidance on flood damage-resistant materials requirements?

    Answer: Technical Bulletin 2

    Technical Bulletin 2 addresses flood damage-resistant materials requirements for buildings in SFHAs.

  3. Structural steel used below the BFE should be protected in what way?

    Answer: Protected against corrosion, such as by galvanizing or appropriate coatings

    Steel is acceptable below BFE when it is corrosion-protected, since floodwater accelerates rust.

  4. Which material is considered UNACCEPTABLE for use below the BFE?

    Answer: Particleboard subflooring

    Particleboard swells and delaminates when wet, making it unacceptable below the BFE.

  5. In a V zone, breakaway walls below the BFE must be constructed of what kind of materials?

    Answer: Flood damage-resistant materials designed to collapse under specified loads without damaging the elevated structure

    Breakaway walls must use flood damage-resistant materials and be designed to fail under base flood conditions without harming the building.

  6. A builder asks whether a fiberglass-faced (paperless) gypsum product is automatically acceptable below the BFE. What is the best answer?

    Answer: No, gypsum products are not considered flood damage-resistant because the gypsum core degrades with prolonged wetting

    FEMA guidance treats gypsum-based wallboard as unacceptable below BFE because the core is damaged by prolonged water exposure.

  7. For utility and service equipment that cannot be elevated above the BFE, NFIP regulations require it to be:

    Answer: Designed and installed to prevent water from entering or accumulating in its components

    44 CFR 60.3(a)(3)(iv) requires service facilities to be designed or located to prevent water from entering or accumulating within components.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. illinoisfloods.org — Fees, test delivery, exam information · verified Nov 2026
  2. floods.org — Late registration, eligibility, fees, exam format, passing score, renewal, retake fee, retake policy, score release, time limit · verified Nov 2026