← All CFM Flashcard Decks

Material Selection Flashcards

7 cards from real CFM practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Material Selection flashcards as text
  1. Which wood product is generally considered acceptable for use below the BFE?

    Answer: Pressure-preservative-treated lumber

    Preservative-treated (or naturally decay-resistant) lumber is acceptable, while OSB, particleboard, and interior plywood are not.

  2. In a coastal V zone, which fastener material is typically recommended for metal connectors exposed to salt spray and flooding?

    Answer: Stainless steel

    FEMA guidance (Technical Bulletin 8) recommends stainless steel connectors in harsh coastal exposures where corrosion is severe.

  3. Which consensus standard, referenced by the International Building Code, specifies flood damage-resistant material requirements for flood-resistant design and construction?

    Answer: ASCE 24

    ASCE 24, Flood Resistant Design and Construction, includes requirements for flood damage-resistant materials.

  4. A homeowner wants to finish a below-BFE enclosure with carpet and padding, claiming the carpet can be replaced after a flood. Is this compliant?

    Answer: No, because carpet is not a flood damage-resistant material

    Carpet and padding are unacceptable below BFE because they require replacement after prolonged flooding.

  5. Which of the following wall materials is acceptable below the BFE?

    Answer: Cement board

    Cement board resists water damage and qualifies as flood damage-resistant.

  6. Why must adhesives be considered when evaluating floor coverings such as vinyl tile below the BFE?

    Answer: Water-soluble adhesives can fail, causing the covering to detach

    Vinyl or rubber coverings are acceptable only when installed with chemical-set (waterproof) adhesives that will not dissolve.

  7. Which statement about flood damage-resistant materials is correct?

    Answer: They are required below BFE even in properly vented enclosures used for parking, access, or storage

    Enclosures below BFE must still be built with flood damage-resistant materials, regardless of insurance status.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. illinoisfloods.org — Fees, test delivery, exam information · verified Nov 2026
  2. floods.org — Late registration, eligibility, fees, exam format, passing score, renewal, retake fee, retake policy, score release, time limit · verified Nov 2026