← All CFESA Flashcard Decks

Electrical and Mechanical Systems Flashcards

7 cards from real CFESA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Electrical and Mechanical Systems flashcards as text
  1. A commercial gas range's igniter glows orange but the burner fails to light. What does this most likely indicate?

    Answer: The igniter is weak and not reaching the minimum current threshold to open the gas valve

    Hot surface igniters must reach a specific current draw (typically 3-4 amps) to signal the gas valve to open; a weak igniter glows but doesn't draw enough current.

  2. What is the function of a run capacitor in a single-phase PSC (permanent split capacitor) motor used in commercial refrigeration?

    Answer: To remain in the circuit continuously, improving motor efficiency and power factor during operation

    A run capacitor stays connected during normal operation, creating a phase shift in the auxiliary winding that improves motor efficiency and reduces current draw.

  3. During installation of a commercial oven, the technician measures 208V between L1 and L2, 208V between L2 and L3, but only 120V between L1 and L3. What does this indicate?

    Answer: An open or high-resistance fault on L3 in the supply panel or connections

    Unequal three-phase voltage readings like this pattern indicate a problem with one supply leg — an open connection or bad breaker on L3.

  4. What is the correct procedure before using an ohmmeter to test a component in a live commercial food equipment circuit?

    Answer: De-energize the equipment, lock out/tag out, and discharge any capacitors before measuring resistance

    Ohmmeter readings are invalid and dangerous in a live circuit; LOTO and capacitor discharge are mandatory safety steps before resistance testing.

  5. A commercial walk-in cooler evaporator fan motor hums but does not start. When the blade is given a manual spin, it runs normally. What component is most likely faulty?

    Answer: The start capacitor or start winding

    If a motor hums but won't self-start and runs fine once manually started, the starting mechanism (start capacitor or start winding) has failed.

  6. Which mechanical failure in a commercial mixer would cause oil to leak from the attachment hub area?

    Answer: A worn or damaged beater shaft oil seal

    The beater shaft oil seal prevents gear oil from migrating down the shaft and escaping at the attachment hub; a worn seal allows oil to leak at that point.

  7. When performing a load test on a commercial food equipment power circuit, what does a significant voltage drop between the panel and the equipment indicate?

    Answer: Excessive resistance in the supply conductors, connections, or breaker due to loose or corroded contacts

    Voltage drop under load reveals high resistance in the circuit path — commonly caused by loose terminals, corroded connections, or an undersized or failing circuit breaker.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy