Diagnostic Troubleshooting Flashcards
7 cards from real CFESA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Diagnostic Troubleshooting flashcards as text
A commercial ice machine produces hollow or incomplete cubes. Refrigerant charge and water supply are confirmed normal. What is the most likely cause?
Answer: Low water distributor flow or clogged water nozzles
Clogged water nozzles in the distributor reduce water coverage over the evaporator plate, resulting in hollow or incomplete ice cube formation.
A technician finds a commercial refrigerator compressor running continuously with the box temperature above setpoint. Suction pressure is low and superheat is high. What does this indicate?
Answer: Undercharge of refrigerant or refrigerant leak
Low suction pressure combined with high superheat is a classic indicator of insufficient refrigerant in the system, pointing to a leak or undercharge.
A combi oven displays an error code indicating a steam generation fault. The technician confirms water supply is present. What should be inspected next?
Answer: Steam generator scale buildup or heating element failure
Scale buildup on the steam generator heating element or a burned-out element are the most common causes of steam generation faults when water supply is adequate.
A gas range burner produces a yellow, lifting flame instead of a blue cone flame. What is the most likely cause?
Answer: Insufficient primary air or partially blocked air shutter
A yellow, lifting flame indicates incomplete combustion due to insufficient primary air mixing with the gas before ignition.
After replacing a thermostat on a commercial fryer, the oil continues to overheat past the setpoint. What is the most likely oversight?
Answer: The new thermostat bulb is not fully seated in its well
If the thermostat sensing bulb is not fully inserted into the capillary well, it senses a lower temperature than actual oil temperature, causing uncontrolled overheating.
A commercial refrigerator compressor hums but does not start. The technician confirms proper voltage at the compressor terminals. What should be tested first?
Answer: Start relay and start capacitor
A humming compressor that fails to start typically indicates a faulty start relay or start capacitor that is not providing the necessary torque to initiate rotation.
A technician is diagnosing a commercial steamer that produces steam but the cooking cavity temperature is below specification. What should be checked?
Answer: Steam generator output pressure and door seal integrity
Inadequate steam generator pressure output or a leaking door seal allows steam to escape, reducing cavity temperature below the required cooking specification.