Building Codes & Standards Flashcards

7 cards from real CFB practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Building Codes & Standards flashcards as text
  1. According to the IBC, a building's 'occupancy classification' is primarily determined by:

    Answer: The intended use of the space

    Occupancy classification under the IBC is based on the intended use or character of occupancy of a building or space.

  2. What is the maximum stair riser height permitted by the IRC for residential stairs?

    Answer: 7.75 inches

    The IRC limits residential stair riser height to a maximum of 7-3/4 inches (7.75 inches) to ensure safe step height.

  3. Which standard defines fire-resistance ratings for building assemblies through standardized testing?

    Answer: ASTM E119

    ASTM E119 is the standard test method for fire tests of building construction and materials, used to determine fire-resistance ratings.

  4. Under IBC Table 601, Type V-B construction allows wood framing with what fire-resistance rating for exterior bearing walls?

    Answer: 0 hours

    IBC Type V-B (unprotected) construction requires 0-hour fire-resistance ratings for all structural elements including exterior bearing walls.

  5. A CFB must verify anchor bolt placement before a slab pour. What is the minimum embedment depth for a standard 1/2-inch anchor bolt per the IRC?

    Answer: 7 inches

    The IRC requires a minimum embedment of 7 inches for anchor bolts connecting sill plates to concrete or masonry foundations.

  6. Which document would a field builder reference to verify that a specific product meets code-approved performance standards?

    Answer: ICC Evaluation Service (ICC-ES) report

    ICC-ES reports (Evaluation Reports) confirm that a product or system meets the requirements of the IBC, IRC, or other model codes.

  7. Penetrations through a fire-rated floor/ceiling assembly must be protected using which method?

    Answer: Listed firestop system

    All penetrations through fire-rated assemblies must be protected with a listed and labeled firestop system tested to maintain the assembly's fire-resistance rating.

Building Codes & Standards Flashcards โ€” CFB Study Cards with Answers