← All CFA Flashcard Decks

Application Equipment and Calibration Flashcards

7 cards from real CFA practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Application Equipment and Calibration flashcards as text
  1. A dry fertilizer applicator needs to apply 150 lbs per acre of a blended product. If the calibration shows the spreader delivers 120 lbs/acre at the current setting, how should the rate be adjusted?

    Answer: Increase the gate opening or agitation speed

    Increasing the gate opening or metering mechanism increases flow rate to achieve the higher target application rate.

  2. What is 'skipping' in the context of spreader calibration, and what causes it?

    Answer: Alternating over- and under-application strips caused by incorrect pass spacing

    Skipping refers to alternating bands of high and low application caused by swath widths that do not match the spreader's effective pattern width.

  3. Which factor does NOT directly affect the output rate of a centrifugal pump on a liquid fertilizer applicator?

    Answer: Color of the solution tank

    Tank color is irrelevant to pump output; speed, back pressure, and impeller condition all directly affect centrifugal pump performance.

  4. What is the purpose of a 'catch test' or 'jug test' when calibrating a sprayer?

    Answer: To verify actual nozzle output matches the expected flow rate

    A catch test collects output from individual nozzles over a timed period to verify they are delivering the correct flow rate.

  5. When applying fertilizer with a boom sprayer, what is the recommended practice when a nozzle becomes clogged mid-application?

    Answer: Stop, clean or replace the nozzle, and retreat the missed area

    A clogged nozzle causes under-application and must be addressed immediately; the missed area must be retreated to ensure proper coverage.

  6. For a drop spreader calibration, you weigh the material in the hopper before and after making a test pass. The hopper lost 1.2 lbs over 100 feet with a 24-inch effective width. What is the application rate in lbs per 1,000 sq ft?

    Answer: 5.0 lbs

    Area = (100 ft x 2 ft) / 1,000 = 0.2 thousand sq ft; rate = 1.2 lbs / 0.2 = 5.0 lbs per 1,000 sq ft.

  7. What does a 'CV' (coefficient of variation) value measure in spreader calibration pattern testing?

    Answer: The statistical variation in distribution uniformity across the spread width

    CV measures the relative standard deviation of material distribution, with lower values indicating more uniform application across the spread pattern.

Application Equipment and Calibration Flashcards — CFA Study Cards with Answers