← All CET Flashcard Decks

Troubleshooting and Diagnostics Flashcards

7 cards from real CET practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Troubleshooting and Diagnostics flashcards as text
  1. A half-wave rectifier produces a lower-than-expected DC output. Which component failure is most likely?

    Answer: The diode has increased forward voltage drop

    An increased diode forward voltage drop reduces the peak output voltage of the rectifier.

  2. When troubleshooting a logic circuit, a gate output is stuck HIGH regardless of inputs. This is called a:

    Answer: Stuck-at-1 fault

    A stuck-at-1 fault means the node is permanently logic HIGH regardless of normal switching inputs.

  3. An op-amp circuit has its output rail-to-rail with no input signal applied. The most likely cause is:

    Answer: Input offset voltage too large or feedback loop open

    A large input offset or open feedback loop causes the high open-loop gain to drive the output to saturation.

  4. During in-circuit testing, measuring resistance on a powered circuit gives unreliable results because:

    Answer: Parallel circuit paths affect the reading

    Parallel paths in a circuit provide alternative current routes, making in-circuit resistance readings inaccurate.

  5. A voltage regulator IC output drops when load current increases. This symptom suggests:

    Answer: The regulator has insufficient input voltage headroom or is failing

    A linear regulator needs a minimum input-output differential (dropout voltage); insufficient headroom or a failing IC causes output sag under load.

  6. A technician uses the 'divide-and-conquer' troubleshooting method. This approach involves:

    Answer: Testing the midpoint of a signal chain to halve the suspected fault area

    Divide-and-conquer splits the signal path at its midpoint, eliminating half the circuit from suspicion with each measurement.

  7. Intermittent faults in electronics are often caused by:

    Answer: Cold solder joints or mechanical connection issues

    Cold solder joints expand and contract with temperature, creating intermittent electrical contact.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. etai.org — Eligibility, fees, exam format, time limit, score validity, test delivery, renewal, passing score, retake policy, score release · verified Oct 2026