NFPA 211 & Local Regulations Flashcards
7 cards from real CCS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 NFPA 211 & Local Regulations flashcards as text
According to NFPA 211, what is the minimum clearance required between a masonry chimney and combustible framing?
Answer: 2 inches
NFPA 211 requires a minimum 2-inch clearance between masonry chimneys and combustible framing members.
Under NFPA 211, a Type HT (high-temperature) factory-built chimney is required when serving which appliance?
Answer: Wood-burning fireplace insert rated above 1,400°F flue gas temperature
Type HT chimneys are designed to handle high-temperature flue gases exceeding 1,400°F, such as those from certain wood-burning appliances.
NFPA 211 requires masonry fireplace hearth extensions to extend at least how far in front of the fireplace opening for openings larger than 6 square feet?
Answer: 20 inches
For fireplace openings larger than 6 square feet, NFPA 211 requires the hearth extension to project at least 20 inches in front of the opening.
What does NFPA 211 specify as the maximum distance a connector can travel horizontally before entering the chimney?
Answer: 50% of the vertical rise of the connector
NFPA 211 limits horizontal connector runs to no more than 75% of the vertical rise to maintain adequate draft.
Under local building codes aligned with NFPA 211, a chimney inspection is typically classified into three levels. Which level inspection is required when a property is sold?
Answer: Level 2
A Level 2 inspection is required upon the sale or transfer of a property, as it includes accessible areas and video scanning of the flue.
NFPA 211 defines 'listed' appliances or chimneys as those that have been:
Answer: Evaluated by a qualified testing laboratory and found to meet specific standards
A 'listed' product has been evaluated by a recognized testing laboratory (such as UL or ETL) and found to comply with applicable standards.
According to NFPA 211, what is the required height of a chimney above a flat roof?
Answer: 3 feet above the roof and 2 feet above any part of the building within 10 feet
NFPA 211 requires chimneys to extend at least 3 feet above the highest point of roof penetration and 2 feet above any portion of the building within 10 feet.