  1. Which inspection level would a CSIA-certified sweep recommend after a chimney sustains damage from a lightning strike?

    Answer: Level 3

    Lightning strikes can cause concealed structural damage that requires a Level 3 invasive inspection to fully assess.

  2. Under NFPA 211 guidelines adopted by CSIA, which inspection level is the minimum required following a chimney fire?

    Answer: Level 2

    After a chimney fire, at minimum a Level 2 inspection is required to assess the extent of damage before further use.

  3. Which of the following is NOT a defined trigger for a Level 2 inspection according to CSIA and NFPA 211?

    Answer: Annual routine sweep with no changes

    Annual routine cleaning with no changes in appliance, fuel, or occupancy only requires a Level 1 inspection.

  4. When a sweep suspects a crack in the flue liner behind a finished wall during a Level 2 inspection, the CORRECT next step is to:

    Answer: Document findings and recommend a Level 3 inspection

    When a hazard is suspected but cannot be confirmed without accessing concealed areas, a Level 3 inspection should be recommended.

  5. Which statement best describes the relationship between inspection levels 1, 2, and 3?

    Answer: Each higher level includes all requirements of lower levels plus additional scope

    Inspection levels are cumulative — Level 2 includes all Level 1 components, and Level 3 includes all Level 1 and 2 components.

  6. A homeowner adds a wood stove insert to an existing masonry fireplace. What inspection level is required BEFORE the insert is used?

    Answer: Level 2, because a change has been made to the appliance

    Adding a new insert constitutes a change in the connected appliance, mandating a Level 2 inspection before operation.

  7. During which inspection level would a sweep be most likely to recommend cutting open an interior wall to inspect hidden flue sections?

    Answer: Level 3

    Opening walls or removing permanently attached building components is characteristic of a Level 3 inspection only.