← All CCHT Flashcard Decks

Vascular Access and Cannulation 1 Flashcards

6 cards from real CCHT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Vascular Access and Cannulation 1 flashcards as text
  1. What is the recommended angle of needle insertion when cannulating a mature arteriovenous fistula?

    Answer: 25–35 degrees

    A 25–35 degree insertion angle allows the needle to enter the vessel lumen cleanly without going through the back wall. Shallower angles risk staying subcutaneous, while steeper angles increase the risk of posterior wall puncture and infiltration.

  2. Which of the following is the earliest and most reliable sign of needle infiltration during a hemodialysis treatment?

    Answer: Localized swelling and pain at the needle insertion site

    Infiltration occurs when the needle tip exits the vessel lumen into surrounding tissue. The immediate result is extravasation of blood or dialysate, causing localized swelling, firmness, and pain at the site. Pressure alarms may change secondarily but are not as specific or early an indicator.

  3. What is the minimum recommended distance between the arterial and venous needles during AV fistula cannulation to minimize recirculation?

    Answer: 5 cm

    Placing needles at least 5 cm (approximately 2 inches) apart prevents recirculation, which occurs when already-dialyzed blood is immediately re-drawn into the arterial needle. Recirculation reduces treatment adequacy and Kt/V.

  4. According to the 'Rule of 6s,' which set of criteria indicates that an AV fistula is mature and ready for cannulation?

    Answer: Flow >600 mL/min, diameter ≥6 mm, depth ≤6 mm, maturation ≥6 weeks

    The Rule of 6s states a fistula is mature when it has blood flow exceeding 600 mL/min, a vessel diameter of at least 6 mm, is no more than 6 mm below the skin surface, and has had at least 6 weeks to mature. These thresholds help ensure reliable cannulation and adequate dialysis delivery.

  5. Which type of hemodialysis vascular access carries the highest risk of bloodstream infection?

    Answer: Tunneled cuffed central venous catheter

    Tunneled cuffed central venous catheters (CVCs) have the highest infection risk among hemodialysis accesses because the catheter provides a direct conduit from the skin surface into the central venous system, bypassing natural skin and vascular barriers. Native AV fistulas have the lowest infection rates and are the preferred access.

  6. In a non-urgent clinical situation, how long should a technician typically wait before cannulating a newly placed synthetic AV graft?

    Answer: 2–4 weeks

    Standard synthetic AV grafts require approximately 2–4 weeks of healing time to allow the graft material to incorporate into surrounding tissue and edema to resolve, reducing the risk of infiltration and hematoma on first cannulation. Early cannulation grafts are a separate product designed for use within 24–72 hours.