Material Selection Flashcards
7 cards from real CBI practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Material Selection flashcards as text
What material should 15- or 20-amp receptacles have when they connect to aluminum branch-circuit conductors?
Answer: CO/ALR rating
Receptacles and switches of 15 and 20 amps that are used with aluminum wire must be marked CO/ALR.
Which cable type is suitable for direct burial in residential work?
Answer: Type UF
Type UF (underground feeder) cable is listed for direct burial, but NM cable is not.
Which material is required for medium-duty firebrick lining a masonry fireplace firebox?
Answer: Firebrick complying with ASTM C27 or C1261
IRC R1001.5 requires firebrick that meets ASTM C27 or C1261, at least 2 inches thick, set in refractory mortar.
What maximum mesh opening does the IRC allow for corrosion-resistant attic ventilation screening?
Answer: 1/4 inch
Attic vent openings must be covered with corrosion-resistant mesh that has openings of at least 1/16 inch and no more than 1/4 inch.
Which preservative treatment use category is required for lumber used in ground contact?
Answer: UC4A
AWPA Use Category 4A covers general ground contact applications for treated wood.
Which change to a concrete mix most improves its resistance to freeze-thaw damage?
Answer: Using air entrainment
Air entrainment creates microscopic voids that relieve internal pressure when water freezes.
When should corrugated sheet-metal ties for anchored masonry veneer be rejected?
Answer: They are thinner than 0.031 inch (22 gage)
IRC R703.8.4.1 requires corrugated veneer ties to be corrosion-resistant sheet metal at least 0.031 inch (22 gage) thick.