โ† All CBI Flashcard Decks

Electrical Systems Inspection Flashcards

6 cards from real CBI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 6 Electrical Systems Inspection flashcards as text
  1. What is proper grounding and why is it essential in electrical systems?

    Answer: Connecting electrical systems to earth ground to provide a safe path for fault currents and prevent shock hazards

    Grounding provides a low-resistance path for fault currents to flow to earth, allowing overcurrent devices (breakers/fuses) to trip quickly during a ground fault, preventing electrical shock and fire.

  2. What is the difference between a 15-amp and 20-amp circuit?

    Answer: A 20-amp circuit uses 12-gauge wire and handles higher loads; a 15-amp circuit uses 14-gauge wire for lighter loads

    20-amp circuits require larger 12 AWG wire and are used for kitchen, bathroom, and garage outlets. 15-amp circuits use 14 AWG wire for general-purpose outlets and lighting in most rooms.

  3. What is the purpose of a main electrical panel inspection?

    Answer: To verify proper installation, correct breaker sizing, appropriate wire connections, grounding, and safe clearances

    Panel inspections verify proper bus connections, correct breaker-to-wire sizing, secure connections, bonding and grounding, working clearances (30 inches front, 36 inches wide), labeling, and absence of double-tapped breakers.

  4. What is a tamper-resistant receptacle and where is it required?

    Answer: A receptacle with internal shutters that prevent insertion of foreign objects, required in all new residential construction

    Tamper-resistant receptacles (TR) have spring-loaded shutters that only open when equal pressure is applied to both slots simultaneously (like a plug), preventing children from inserting objects. Required in all 15A and 20A residential outlets.

  5. What wire types are approved for residential branch circuit wiring?

    Answer: NM cable (Romex) for dry locations and UF cable for underground/wet locations in most residential applications

    NM (non-metallic sheathed) cable is the most common residential wiring for dry interior locations. UF cable is rated for direct burial. MC (metal-clad) cable is required in some jurisdictions and commercial applications.

  6. What should an inspector verify about bathroom exhaust ventilation?

    Answer: That a mechanical exhaust fan vented to the exterior is installed in every bathroom, or that an operable window of adequate size is provided

    Building codes require bathrooms to have either a mechanical exhaust fan ducted to the exterior or an operable window with minimum size. The fan must exhaust outdoors, not into an attic or crawl space.