← All AWS Flashcard Decks

Welding Safety & OSHA Regulations Flashcards

6 cards from real AWS practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Welding Safety & OSHA Regulations flashcards as text
  1. OSHA's permissible exposure limit (PEL) for manganese fume in welding environments is:

    Answer: 0.2 mg/m³ as a ceiling value

    OSHA's PEL for manganese fume is 0.2 mg/m³ as a ceiling value — this limit must not be exceeded at any time during the work shift.

  2. A welding fume extraction system should position the capture hood at what distance from the welding arc?

    Answer: 2–4 inches from the arc source to capture fumes before they rise

    Local exhaust ventilation (LEV) capture hoods should be positioned 2–4 inches from the welding arc to capture fumes at the source before they reach the welder's breathing zone.

  3. Which OSHA standard governs general industry welding, cutting, and brazing?

    Answer: 29 CFR 1910 Subpart Q

    29 CFR 1910 Subpart Q covers Welding, Cutting and Brazing in general industry. Construction welding falls under 29 CFR 1926 Subpart J.

  4. Confined space welding hazards include oxygen deficiency, fire/explosion risk from shielding gas accumulation, and:

    Answer: Toxic fume concentration that can rapidly reach dangerous levels

    In confined spaces, welding fumes accumulate rapidly and can quickly exceed safe exposure limits since there is no natural dilution ventilation, creating an immediately dangerous to life and health (IDLH) atmosphere.

  5. The auto-darkening welding lens (ADF) must meet which ANSI standard for welding eye protection?

    Answer: ANSI Z87.1

    Welding helmets and auto-darkening filters must meet ANSI Z87.1 — the standard for occupational and educational personal eye and face protection devices.

  6. When welding near combustible materials is unavoidable, OSHA and AWS standards require a fire watch for:

    Answer: At least 30 minutes after welding is completed

    OSHA and NFPA 51B (Hot Work) require a fire watch to be maintained for at least 30 minutes after welding operations are completed to detect and extinguish any smoldering fires.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. aws.amazon.com — Fees, exam format, time limit, score validity, renewal, passing score, retake fee, retake policy, score release, test delivery · verified Nov 2026