  1. A plug-in hybrid charges normally from a Level 2 EVSE at home but will not accept charge from any other EVSE, and a second known-good vehicle charges fine at those other locations. Which is the best first diagnostic check?

    Answer: Check the control pilot and proximity pilot signals and onboard charger communication DTCs with a scan tool and EVSE tester

    The charging problem depends on the EVSE, so the handshake signals between the vehicle and those units should be checked before replacing expensive parts.

  2. A hybrid idles at a stop with the engine running continuously and will not auto-stop, even though the engine is fully warm and the A/C is off. Which condition would most likely cause this?

    Answer: The high-voltage battery state of charge is low and the system needs to charge it

    When state of charge is low, the control system keeps the engine running to drive the generator and recharge the traction battery.

  3. Inside a hybrid inverter, which output characteristic is varied to change the speed of an AC traction motor?

    Answer: The frequency of the three-phase AC it produces

    The inverter produces three-phase AC from the DC bus. The motor's speed follows the frequency of that output, while the current and voltage amplitude control torque.

  4. What is the function of the proximity pilot circuit in an SAE J1772 connector?

    Answer: It detects that the connector is plugged in and latched, and the vehicle uses it to prevent driving while connected

    The proximity pilot shows the vehicle that a connector is present and whether the latch release is pressed. The vehicle uses this to prevent driving away while plugged in.

  5. A hybrid is in READY mode and the HV battery state of charge is normal, but the 12V auxiliary battery voltage keeps falling and the 12V charging warning is on. Which component should be tested first?

    Answer: The DC/DC converter output, including its 12V supply circuit and fuse

    On a hybrid the DC/DC converter replaces the alternator and supplies the 12V system. A falling 12V battery with a healthy HV battery points to the converter or its output circuit.

  6. A hybrid vehicle sets a resolver signal circuit DTC for the drive motor and the 'Ready' light will not come on. What is the most likely reason the system disables motor operation?

    Answer: The inverter cannot time the phase currents without valid rotor position data

    The inverter needs accurate rotor position to energize the stator phases in the right sequence. Without it, the system shuts down or limits motor operation.

  7. A hybrid vehicle shows READY, but the engine does not start when the system calls for it. The motor-generator spins the engine normally. What should the technician verify first?

    Answer: That fuel pressure, injector pulses, and spark are present during the crank event

    If the engine is being cranked by the motor-generator but does not fire, the fault is in fuel, spark, or engine management, just as on a conventional vehicle.

  8. Which statement correctly distinguishes a typical optical or magnetic rotary encoder from a resolver used for rotor position?

    Answer: An encoder produces digital pulse signals, while a resolver produces analog AC signals

    Encoders output digital pulses, typically in quadrature, while resolvers output analog sine and cosine amplitude-modulated signals.

  9. A technician suspects an HV electric A/C compressor has an internal insulation fault. Which tool is appropriate to verify isolation between the HV terminals and the compressor housing, after the HV system is disabled?

    Answer: An insulation resistance tester (megohmmeter)

    An insulation tester applies a test voltage and measures very high resistances to confirm isolation. A standard multimeter cannot detect marginal insulation leakage.

  10. When replacing a single weak module in an aged HV battery pack, which practice is most appropriate?

    Answer: Match the replacement module's state of charge and capacity to the pack as the manufacturer specifies

    A mismatched module can cause imbalance, premature limiting, or faults, so state of charge and capacity must fit the remaining pack.

  11. A technician needs to perform a compression test on a full hybrid whose engine is normally cranked by a motor-generator. Which method is the most appropriate?

    Answer: Use the manufacturer's service or inspection mode so the engine is cranked by the motor with fuel and ignition disabled

    Many hybrids provide a service mode that cranks the engine with a motor-generator while fuel injection and ignition are inhibited. This allows a safe, controlled compression test.

  12. After the vehicle is shut off and the controller commands the HV contactors open, HV bus voltage at the inverter stays near full pack voltage and a contactor-stuck DTC is stored. What is the most likely cause?

    Answer: A main contactor with welded contacts

    If bus voltage remains after the contactors are commanded open, current is still passing through a contactor whose contacts have welded closed.

  13. On a hybrid transaxle where the motor-generators are cooled and lubricated by the transmission fluid, why should a generic ATF not be substituted for the specified fluid?

    Answer: The specified fluid is formulated for the electrical insulation properties required around the motor windings

    Fluid that contacts motor windings must meet specific electrical insulation and friction requirements. An incorrect fluid can degrade insulation or harm the transaxle.

  14. With the battery disconnected and the ignition off, a technician measures resistance between CAN High and CAN Low at the data link connector and reads about 120 ohms. What does this most likely indicate on a standard high-speed CAN network?

    Answer: One of the two 120-ohm terminating resistors is open or missing

    A normal high-speed CAN bus has two 120-ohm terminators in parallel, giving about 60 ohms. A reading near 120 ohms means one terminator is not in the circuit.

  15. What does the high-voltage interlock loop (HVIL) do when a connector or service cover in its circuit is opened?

    Answer: It signals the control module to open the contactors and shut down the HV system

    HVIL is a low-voltage monitoring circuit. A break in the loop tells the module that an HV connection is open, so it disables the HV system.

  16. A technician suspects insulation breakdown between a traction motor phase winding and the motor housing. Which test is the most appropriate way to check for it?

    Answer: An insulation resistance test between each phase terminal and the case, using the specified test voltage

    Insulation leakage to ground is found by measuring resistance from each winding to the case with an insulation tester at the manufacturer's specified voltage. A low-voltage ohmmeter can miss insulation faults.

  17. Why are leather protector gloves worn over Class 0 rubber insulating gloves when working on HV components?

    Answer: The leather protects the rubber from cuts and punctures that would compromise insulation

    Rubber insulating gloves protect only while they are intact, and the leather shell guards them against mechanical damage.

  18. Why must the coolant specified by the manufacturer be used in a hybrid inverter and motor cooling loop?

    Answer: Because the coolant formulation protects against corrosion and is chosen to limit electrical conductivity near high-voltage components

    Specified coolant provides the correct corrosion protection and is formulated with high-voltage electrical components in mind. The wrong product can harm components and affect isolation.

  19. What is the primary purpose of the high-voltage interlock loop (HVIL) in a hybrid or electric vehicle?

    Answer: To use a low-voltage circuit that confirms HV connectors and covers are in place, so the system can open the contactors if the loop is broken

    The HVIL is a low-voltage monitoring circuit run through HV connectors, service disconnects and covers. If it opens, the controller sets a DTC and commands the HV contactors open.

  20. A hybrid uses a brake-by-wire system with a stroke simulator. During a normal brake application, what is the stroke simulator's function?

    Answer: It provides pedal feel while the driver's master cylinder pressure is isolated from the wheel circuits

    In brake-by-wire systems the pedal's master cylinder is isolated and feeds the simulator, giving normal pedal feel. The brake ECU separately controls wheel brake pressure to blend regenerative and hydraulic braking.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy