Internal Combustion Engine Flashcards
11 cards from real ASE L3 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 11 Internal Combustion Engine flashcards as text
A hybrid vehicle is silent and the READY indicator is lit while stopped at a light. What does this indicate?
Answer: The vehicle is in run mode, and the engine may be off until the control system requests it to start
A lit READY indicator means the system is active and the vehicle can drive. The engine may be stopped by design and is started when the hybrid control system calls for it.
A hybrid will not enter READY mode. The 12-volt battery is fully charged and there are no stored codes. Scan data shows the brake pedal switch status does not change when the pedal is pressed. What is the most likely cause?
Answer: A faulty stop lamp switch or its circuit, so the start request is not enabled
Most push-button hybrids require a valid brake pedal input before the system will enter READY. If the switch signal never changes, the start request is not accepted.
A technician needs to perform a compression test on a full hybrid whose engine is normally cranked by a motor-generator. Which method is the most appropriate?
Answer: Use the manufacturer's service or inspection mode so the engine is cranked by the motor with fuel and ignition disabled
Many hybrids provide a service mode that cranks the engine with a motor-generator while fuel injection and ignition are inhibited. This allows a safe, controlled compression test.
A hybrid idles at a stop with the engine running continuously and will not auto-stop, even though the engine is fully warm and the A/C is off. Which condition would most likely cause this?
Answer: The high-voltage battery state of charge is low and the system needs to charge it
When state of charge is low, the control system keeps the engine running to drive the generator and recharge the traction battery.
After replacing the coolant in a hybrid's inverter cooling loop, the technician wants to remove trapped air. Which approach is the most appropriate?
Answer: Use the scan tool's active test to run the electric coolant pump while topping off the reservoir
The inverter loop uses an electric pump that can usually be commanded with the scan tool. Running it while adding coolant bleeds air safely.
A plug-in hybrid owner says the fuel filler door will not release and a hissing sound is heard when the door finally opens. Which fault is the most likely cause?
Answer: A fuel tank isolation valve that is stuck closed, preventing tank pressure from being relieved
Plug-in hybrids use a sealed, pressurized fuel tank. If the isolation valve does not open to vent pressure, the filler door will stay locked or release only after pressure bleeds off.
Why are EVAP monitors and purge control more difficult to complete on a hybrid than on a conventional vehicle?
Answer: The engine runs intermittently, so intake vacuum for purging is available less often
Purge flow depends on intake manifold vacuum while the engine runs. Hybrids run the engine less, so they need special strategies to purge and test the system.
Which feature of an Atkinson-cycle engine used in many hybrids explains why its effective compression is lower than its geometric compression ratio?
Answer: The intake valve stays open late into the compression stroke
Late intake valve closing pushes part of the intake charge back out of the cylinder, reducing the effective compression stroke and pumping losses.
A hybrid's engine starts and stops more often than normal and the heater output is weak. The coolant temperature gauge reads lower than normal at highway speed. Which component should be checked first?
Answer: The thermostat, which may be stuck open
A thermostat stuck open keeps coolant temperature low, which causes weak heater output and can make the hybrid system run the engine more to try to warm it.
A hybrid vehicle shows READY, but the engine does not start when the system calls for it. The motor-generator spins the engine normally. What should the technician verify first?
Answer: That fuel pressure, injector pulses, and spark are present during the crank event
If the engine is being cranked by the motor-generator but does not fire, the fault is in fuel, spark, or engine management, just as on a conventional vehicle.
Before a technician disconnects the 12-volt battery on a hybrid in preparation for service, which step is most appropriate?
Answer: Turn the vehicle off, wait for the system to fully shut down, and follow the manufacturer's procedure
The vehicle must be fully powered down before disconnecting the 12-volt battery, and the manufacturer's order of steps should be followed.