  1. What is the primary purpose of the high-voltage interlock loop (HVIL) in a hybrid or electric vehicle?

    Answer: To use a low-voltage circuit that confirms HV connectors and covers are in place, so the system can open the contactors if the loop is broken

    The HVIL is a low-voltage monitoring circuit run through HV connectors, service disconnects and covers. If it opens, the controller sets a DTC and commands the HV contactors open.

  2. A technician has removed the service disconnect on a hybrid vehicle and waited the time specified by the manufacturer. What should be done next, before touching any HV conductors?

    Answer: Verify zero voltage at the HV terminals using a CAT III-rated meter while wearing rated insulating gloves

    After disabling the system and waiting, the technician must prove the absence of voltage with a properly rated meter and PPE. Assuming the system is dead is not safe.

  3. What does a megohmmeter (insulation tester) measure when used on an HV system, and what does a low reading indicate?

    Answer: Resistance between an HV conductor and chassis ground; a low reading indicates an isolation fault

    An insulation tester applies a test voltage and measures resistance between HV conductors and chassis. Low resistance means current can leak to ground, which is an isolation fault.

  4. During HV system startup, what is the purpose of the pre-charge circuit?

    Answer: To limit inrush current into the inverter's capacitors before the main contactors fully close

    The pre-charge resistor lets the bus capacitors charge gradually. This prevents a large inrush current that could weld the main contactors.

  5. A hybrid will not go READY and shows several unrelated communication DTCs from different modules. The 12-volt battery reads 9.8 volts at rest. What is the best next step?

    Answer: Charge and load-test the 12-volt battery, then clear codes and recheck

    Low 12-volt voltage can cause many modules to drop out and set false communication DTCs. The cheapest and most likely cause should be corrected first.

  6. On an SAE J1772 AC charging connection, what does the duty cycle of the control pilot PWM signal communicate to the vehicle?

    Answer: The maximum current the charging equipment can supply

    The EVSE sets the control pilot duty cycle to tell the vehicle the maximum available charging current. The onboard charger then limits its draw to that value.

  7. What is the function of the proximity pilot circuit in an SAE J1772 connector?

    Answer: It detects that the connector is plugged in and latched, and the vehicle uses it to prevent driving while connected

    The proximity pilot shows the vehicle that a connector is present and whether the latch release is pressed. The vehicle uses this to prevent driving away while plugged in.

  8. With the battery disconnected and the ignition off, a technician measures resistance between CAN High and CAN Low at the data link connector and reads about 120 ohms. What does this most likely indicate on a standard high-speed CAN network?

    Answer: One of the two 120-ohm terminating resistors is open or missing

    A normal high-speed CAN bus has two 120-ohm terminators in parallel, giving about 60 ohms. A reading near 120 ohms means one terminator is not in the circuit.

  9. On a healthy high-speed CAN bus, what are the approximate voltages on CAN High and CAN Low during a dominant bit?

    Answer: CAN High about 3.5 V, CAN Low about 1.5 V

    In the dominant state, CAN High rises to about 3.5 V and CAN Low drops to about 1.5 V. In the recessive state both sit near 2.5 V.

  10. After the vehicle is shut off and the controller commands the HV contactors open, HV bus voltage at the inverter stays near full pack voltage and a contactor-stuck DTC is stored. What is the most likely cause?

    Answer: A main contactor with welded contacts

    If bus voltage remains after the contactors are commanded open, current is still passing through a contactor whose contacts have welded closed.

  11. A plug-in hybrid charges normally from a Level 2 EVSE at home but will not accept charge from any other EVSE, and a second known-good vehicle charges fine at those other locations. Which is the best first diagnostic check?

    Answer: Check the control pilot and proximity pilot signals and onboard charger communication DTCs with a scan tool and EVSE tester

    The charging problem depends on the EVSE, so the handshake signals between the vehicle and those units should be checked before replacing expensive parts.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. ase.com — Test delivery, registration deadline, test dates, eligibility, time limit, score validity · verified Nov 2026
HV Safety, Charging and Networks Flashcards — ASE L3 Study Cards with Answers