← All ARRT Flashcard Decks

Mixed Deck — All ARRT Topics Flashcards

100 cards from real ARRT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 20 Mixed Deck — All ARRT Topics flashcards as text
  1. Which fluoroscopic procedure is specifically designed to evaluate the swallowing mechanism and detect aspiration?

    Answer: Modified barium swallow (videofluoroscopic swallow study)

    The modified barium swallow (videofluoroscopic swallow study) is performed with a speech-language pathologist to assess oropharyngeal swallowing function and detect aspiration.

  2. A CAT scan of the patient's head is being performed. The patient reports feeling queasy and having trouble breathing after receiving a contrast injection. Which kind of shock is the patient going through?

    Answer: Anaphylactic

    Anaphylaxis shock is a serious allergic reaction that can be fatal. Breathing difficulties, nausea, vomiting, and low blood pressure are possible side effects. The treatment for anaphylaxis is an injection of epinephrine. Infections are the cause of septic shock. Cardiogenic shock will result from cardiac issues. Your nervous system injury results in neurogenic shock.

  3. In a lateral projection of the paranasal sinuses, the central ray should be directed to a point:

    Answer: Midway between the outer canthus and the EAM.

    For a true lateral projection of the paranasal sinuses, the central ray is centered to a point midway between the outer canthus (the outer corner of the eye) and the external auditory meatus (EAM). This centering ensures that all four sinus groups (frontal, ethmoid, sphenoid, and maxillary) are included and properly demonstrated in the image.

  4. Which radioactive decay mode results in the emission of an electron from the nucleus?

    Answer: Beta-minus decay

    Beta-minus decay occurs when a neutron converts to a proton, releasing an electron (beta particle) and an antineutrino from the nucleus.

  5. A radiograph exhibits a wide latitude (long scale) of contrast. Which exposure factor most directly caused this?

    Answer: High kVp

    Higher kVp produces more penetrating, homogenous radiation that results in low contrast (long gray scale) across the image.

  6. Which of the following radiographic projections of the skull is specifically designed to demonstrate the petrous pyramids, internal auditory canals, and mastoid air cells of the temporal bone?

    Answer: Axioanterior oblique posterior (Stenvers method)

    The Stenvers method, an axioanterior oblique posterior projection, is specifically designed to visualize the structures within the temporal bone. By rotating the head 45 degrees and angling the central ray 12-14 degrees cephalad, this view projects the petrous pyramid, internal auditory canal, and mastoid process in profile, free from superimposition.

  7. Which of the following is the most radiosensitive tissue according to the law of Bergonié and Tribondeau?

    Answer: Bone marrow cells

    Bone marrow cells are highly mitotic and undifferentiated, making them among the most radiosensitive tissues in the body.

  8. Which of the following is a sign of an inadequate inspiration on a PA chest radiograph?

    Answer: Fewer than 10 posterior ribs visible above the diaphragm

    A diagnostic PA chest requires at least 10 posterior ribs visible above the diaphragm; fewer indicates inadequate inspiration and a suboptimal study.

  9. Which factor primarily controls quantum noise (quantum mottle) in a digital radiographic image?

    Answer: mAs (number of photons reaching the detector)

    Quantum mottle is caused by insufficient photons reaching the detector; increasing mAs increases photon fluence and reduces this noise.

  10. A digital radiograph of a knee is produced with optimal brightness and contrast. However, the Deviation Index (DI) value is +2.5. How should the technologist interpret this value?

    Answer: The image is significantly overexposed, and the mAs should be reduced for future similar exams.

    The Deviation Index (DI) indicates how much the actual exposure to the receptor deviates from a pre-set target exposure. A DI of 0 is ideal. A positive DI indicates overexposure, while a negative DI indicates underexposure. A DI of +1 represents about 25% overexposure, and a DI of +3 represents a 100% (doubling) of the intended exposure. Therefore, a DI of +2.5 signifies significant overexposure, and the technologist should reduce the exposure technique (typically mAs) to adhere to the ALARA principle for subsequent examinations.

  11. Which of the following describes the primary function of a falling load generator?

    Answer: To use the maximum heat capacity of the tube to achieve the shortest possible exposure time.

    A falling load generator starts the exposure with the highest possible mA and then drops the mA to lower levels as the tube's heat loading capacity is reached. This process is designed to deliver the desired mAs in the shortest time possible, which is crucial for minimizing motion artifacts.

  12. What is the effective dose limit for a declared pregnant radiation worker during the entire gestation period?

    Answer: 5 mSv

    NCRP recommends limiting fetal dose to no more than 5 mSv (0.5 rem) over the entire gestational period once pregnancy is declared.

  13. An 82-year-old female patient with limited mobility needs to be transferred from her wheelchair to the x-ray table for a hip examination. The patient is able to bear some weight on her legs. What is the most appropriate transfer method?

    Answer: A pivot transfer with the technologist's assistance.

    For a patient who can bear some weight, the pivot transfer is a safe and efficient method. The technologist positions the wheelchair parallel to the table, has the patient stand, pivot, and then sit on the table with guidance and support. This method utilizes the patient's own strength while ensuring safety.

  14. In digital radiography, what is 'histogram clipping'?

    Answer: Loss of image data when anatomical densities fall outside the detector's dynamic range

    Histogram clipping occurs when exposure values exceed the detector's usable dynamic range, causing lost (clipped) data at the bright or dark extremes.

  15. The oxygen enhancement ratio (OER) is MOST relevant in which radiobiological context?

    Answer: Comparing tumor hypoxia sensitivity to radiation

    OER quantifies how much more radiation dose is needed to achieve the same cell kill in hypoxic versus well-oxygenated conditions, directly relevant to tumor radiobiology.

  16. Which term describes the minimum detectable difference in tissue density that can be distinguished on a radiograph?

    Answer: Contrast resolution

    Contrast resolution is the ability to distinguish between tissues of similar attenuation — the minimum density difference that can be detected.

  17. According to the Law of Bergonie and Tribondeau, which of the following cells would be MOST radiosensitive?

    Answer: Lymphocytes

    The Law of Bergonie and Tribondeau states that radiosensitivity is highest in cells that have a high mitotic rate, are undifferentiated (unspecialized), and have a long dividing future. [17, 20] Lymphocytes are highly mitotic and undifferentiated, making them one of the most radiosensitive cell types in the body. [21] Nerve and muscle cells are highly specialized and do not divide, making them radioresistant. [13] Chondrocytes (cartilage cells) are also specialized and have a low mitotic rate.

  18. What is the effect of decreasing the object-to-image receptor distance (OID) on image sharpness?

    Answer: Increases sharpness by reducing geometric unsharpness

    Minimizing OID reduces the distance between the object and receptor, decreasing the penumbra (geometric unsharpness) and improving recorded detail.

  19. Barium sulfate is contraindicated when which clinical condition is suspected?

    Answer: Bowel perforation

    Barium sulfate is contraindicated with suspected bowel perforation because leakage into the peritoneum causes severe peritonitis.

  20. Which target interaction results from a cathode electron decelerating?

    Answer: Bremsstrahlung

    Also referred to as "braking" radiation, bremsstrahlung radiation is produced when an incident cathode electron changes course and slows down as it approaches a target atom's nucleus. Target contact brought on by the withdrawal of an inner shell electron from the target is known as characteristic radiation. Compton scattering generates scattered radiation through an interaction with matter rather than the target. An interaction with matter that doesn't result in ionization is called coherent scattering. It is not a target interaction, but rather a photon interaction with matter.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. arrt.org — Registration deadline, test dates, score release, retake policy, passing score, eligibility, fees, renewal, retake fee, exam information · verified Nov 2026
  2. pearsonvue.com — Test delivery · verified Nov 2026
  3. assets-us-01.kc-usercontent.com — Exam format, time limit · verified Nov 2026