Read the first 6 Digital Imaging and Exposure Factors flashcards as text
  1. In digital radiography, which exposure indicator value signifies optimal exposure on most current CR/DR systems?

    Answer: EI of 300 (system-dependent target near 300)

    Most systems target an Exposure Index around 300 (±30%), though exact targets are vendor-specific and defined by the manufacturer.

  2. What does a deviation index (DI) of 0 indicate in a digital imaging system?

    Answer: Exposure is exactly at the target exposure index

    A deviation index of 0 means the actual exposure exactly matched the target exposure index, indicating optimal exposure.

  3. Which primary exposure factor has the greatest effect on subject contrast in digital radiography?

    Answer: kVp (kilovoltage peak)

    kVp controls the energy and penetrating power of the X-ray beam, directly determining the differential absorption that creates subject contrast.

  4. In computed radiography (CR), what component captures the latent image?

    Answer: Photostimulable phosphor (PSP) imaging plate

    CR uses a photostimulable phosphor imaging plate that stores a latent image as trapped electrons until scanned by a laser reader.

  5. What is the primary advantage of direct conversion flat-panel detectors (FPD) over indirect conversion FPDs?

    Answer: Superior spatial resolution due to no light-spreading step

    Direct conversion detectors convert X-rays directly to electrical signals without an intermediate light step, eliminating blur from light spread and improving spatial resolution.

  6. Which artifact in digital radiography results from a CR imaging plate not being completely erased before reuse?

    Answer: Ghost image (ghosting)

    Ghosting occurs when residual signal from a prior exam remains on the phosphor plate because erasure was incomplete, superimposing an old image onto the new one.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. arrt.org — Registration deadline, test dates, score release, retake policy, passing score, eligibility, fees, renewal, retake fee, exam information · verified Nov 2026
  2. pearsonvue.com — Test delivery · verified Nov 2026
  3. assets-us-01.kc-usercontent.com — Exam format, time limit · verified Nov 2026