ARRT Computed Tomography (CT) Certification Examination — Questions and Answers
Question 1: On axial CT at the level of the umbilicus, which abdominal wall muscle is most lateral?
- Internal oblique
- External oblique (Correct answer)
- Transversus abdominis
- Rectus abdominis
Correct answer: External oblique
The external oblique is the most superficial and lateral of the flat abdominal wall muscles, lying outside the internal oblique.
Question 2: For a CT scan of the spine performed to evaluate for disk herniation, which reconstruction kernel is preferred?
- Ultra-high-resolution kernel
- Lung (high-frequency) kernel
- Bone (high-frequency) kernel
- Standard soft tissue kernel (Correct answer)
Correct answer: Standard soft tissue kernel
A standard or intermediate soft tissue kernel is preferred for disk and neural structure evaluation, reducing noise while preserving relevant detail.
Question 3: In CT, 'effective mAs' (mAs/pitch) is important because:
- It remains constant regardless of pitch, maintaining image noise consistency (Correct answer)
- It sets the rotation time only
- It controls the display window
- It determines the field of view
Correct answer: It remains constant regardless of pitch, maintaining image noise consistency
Effective mAs = mAs ÷ pitch; keeping this constant as pitch changes maintains consistent image noise regardless of table speed.
Question 4: During a CT-guided biopsy procedure, which measure BEST reduces radiation exposure to the interventional CT technologist?
- Using fluoroscopy-like CT intermittently and stepping back during exposures (Correct answer)
- Wearing a lead apron only when the patient is being positioned
- Reducing tube current to zero between acquisitions
- Standing at the gantry opening throughout the procedure
Correct answer: Using fluoroscopy-like CT intermittently and stepping back during exposures
Intermittent CT fluoroscopy combined with stepping away from the gantry during exposures significantly reduces occupational dose during interventional procedures.
Question 5: A CT technologist completes a 3-credit online module from an ARRT-approved sponsor. How should this be recorded?
- Only if the module includes a hands-on component
- As Category B self-study credit
- It counts only if completed before the renewal year begins
- As 3 Category A CE credits (Correct answer)
Correct answer: As 3 Category A CE credits
Online modules from ARRT-approved sponsors qualify as Category A CE credits and count toward the 24-credit renewal requirement.
Question 6: For a CT of the paranasal sinuses ordered to guide functional endoscopic sinus surgery (FESS), which plane is most critical for the surgeon?
- Coronal plane (Correct answer)
- Oblique plane
- Sagittal plane
- Axial plane
Correct answer: Coronal plane
The coronal plane directly depicts the ostiomeatal complex, sinus drainage pathways, and the relationship to the orbit and skull base — essential for FESS planning.
Question 7: A patient receiving oxygen via nasal cannula at 2 L/min needs a portable chest X-ray. The technologist should:
- Switch the patient to a face mask before imaging
- Leave the oxygen in place and proceed with the exam (Correct answer)
- Discontinue oxygen as it interferes with imaging
- Remove the oxygen cannula during the exposure
Correct answer: Leave the oxygen in place and proceed with the exam
Supplemental oxygen should not be interrupted; nasal cannulas do not significantly affect image quality and the patient's oxygenation status must be maintained.
Question 8: What are the principles of mission command?
- Technology, firepower, logistics
- Speed, power, aggression
- Competence, mutual trust, shared understanding, commander's intent (Correct answer)
- Rank, authority, obedience
Correct answer: Competence, mutual trust, shared understanding, commander's intent
Mission command empowers subordinates through trust, shared understanding of the commander's intent, and disciplined initiative.
Question 9: On axial CT of the orbit, which extraocular muscle is located at the medial wall of the orbit?
- Superior rectus
- Medial rectus (Correct answer)
- Superior oblique
- Inferior oblique
Correct answer: Medial rectus
The medial rectus muscle runs along the medial orbital wall and is the most commonly enlarged muscle in thyroid eye disease.
Question 10: Which of the following activities can count toward the continuing education credits for ARRT CT certification?
- Publishing a research article in a professional journal
- Completing a patient care workshop
- All of the above (Correct answer)
- Attending an industry conference
Correct answer: All of the above
ARRT accepts a wide range of activities for continuing education (CE) credits, provided they are relevant to the radiologic sciences. This includes attending industry conferences, participating in patient care workshops, and even publishing research articles in professional journals. The goal is to encourage diverse learning that enhances professional practice.
Question 11: Which regulatory body sets the annual occupational effective dose limit of 50 mSv in the United States?
- CDC
- ARRT
- FDA
- NRC and Agreement States (Correct answer)
Correct answer: NRC and Agreement States
The Nuclear Regulatory Commission (NRC) and Agreement State regulations set the 50 mSv/year occupational effective dose limit (10 CFR 20).
Question 12: A radiologic technologist notices that CT images of the liver appear uniformly noisy despite using standard mAs. The MOST appropriate first corrective action is:
- Reduce the reconstruction FOV by 50%
- Switch to a narrower window width for display
- Double the mAs for the repeat scan immediately
- Verify that the correct reconstruction kernel and algorithm are applied (Correct answer)
Correct answer: Verify that the correct reconstruction kernel and algorithm are applied
Verifying protocol settings (kernel, algorithm, slice thickness) first ensures the source of apparent noise is identified before unnecessarily increasing dose.
Question 13: CT colonoscopy (virtual colonoscopy) relies on which post-processing technique to create a simulated fly-through view of the colon lumen?
- Volume rendering with endoluminal navigation (Correct answer)
- Maximum intensity projection
- Minimum intensity projection
- Subtraction imaging
Correct answer: Volume rendering with endoluminal navigation
Volume rendering with endoluminal navigation uses the air-distended colon as a flight path, generating a simulated colonoscopic perspective of the mucosal surface.
Question 14: Which approach is used in a split-bolus IV contrast protocol for CT of the abdomen?
- A single rapid bolus followed by immediate scanning
- Two separate injections given at different time points before scanning (Correct answer)
- Saline flush only with no contrast
- Contrast injected into the portal vein directly
Correct answer: Two separate injections given at different time points before scanning
The split-bolus technique delivers two injections at different time intervals so a single scan pass captures both nephrographic and excretory phases simultaneously.
Question 15: A patient taking metformin for type 2 diabetes is receiving IV iodinated contrast. Per ACR guidelines, when should metformin be withheld after contrast administration in a patient with normal renal function?
- Withhold only if the patient has an allergic reaction
- Withhold for 72 hours regardless of renal function
- Withhold for 24 hours before and after the exam
- It does not need to be withheld in patients with normal renal function (Correct answer)
Correct answer: It does not need to be withheld in patients with normal renal function
ACR guidelines state that patients with normal renal function (eGFR ≥ 30) receiving IV contrast do not need to withhold metformin.
Question 16: The inverse square law states that radiation intensity is related to distance by which relationship?
- Intensity is directly proportional to distance
- Intensity is inversely proportional to the square of the distance (Correct answer)
- Intensity decreases linearly with distance
- Intensity is inversely proportional to the cube of the distance
Correct answer: Intensity is inversely proportional to the square of the distance
The inverse square law: I ∝ 1/d², meaning doubling the distance from the source reduces intensity to one-quarter of its original value.
Question 17: How does earning ARRT CT certification typically affect a technologist's hourly wage compared to uncertified peers?
- It reduces wages due to higher employer expectations
- It typically results in a 5–15% higher hourly wage (Correct answer)
- It guarantees a doubling of salary
- It has no measurable impact on wages
Correct answer: It typically results in a 5–15% higher hourly wage
Studies and salary surveys consistently show certified CT technologists earn 5–15% more per hour than non-certified counterparts.
Question 18: CT calcium scoring of the coronary arteries uses which post-processing method to quantify calcification?
- Subtraction of non-contrast from contrast images
- Agatston scoring based on lesion area and peak Hounsfield unit density (Correct answer)
- MIP projection over the cardiac cycle
- Volume rendering with opacity mapping
Correct answer: Agatston scoring based on lesion area and peak Hounsfield unit density
Agatston scoring multiplies the area of each calcified lesion by a density factor based on peak HU (1–4 scale), then sums all lesions to yield the total calcium score.
Question 19: What is the primary purpose of selecting a small reconstruction FOV (field of view) during CT image reconstruction?
- To increase the pixel size for better soft tissue contrast
- To decrease image noise
- To reduce patient dose
- To improve spatial resolution by sampling more detail per pixel (Correct answer)
Correct answer: To improve spatial resolution by sampling more detail per pixel
A smaller reconstruction FOV divides the imaged area into the same matrix of pixels, resulting in smaller pixel size and therefore higher spatial resolution of the region of interest.
Question 20: Which CT feature of a pulmonary nodule is most associated with malignancy?
- Smooth well-defined margins
- Spiculated margins with pleural tethering (Correct answer)
- Stippled central calcification
- Laminated calcification pattern
Correct answer: Spiculated margins with pleural tethering
Spiculated margins with pleural tethering are high-risk features indicating likely malignant invasion of adjacent lung parenchyma.
Question 21: For a radiologic technologist considering subspecialty practice, which statement about ARRT CT certification scope is most accurate?
- CT certification is equivalent to a fellowship in CT radiology
- CT certification covers interventional radiology procedures as well
- CT certification validates technical performance skills, not image interpretation or diagnosis (Correct answer)
- CT certification qualifies technologists to independently interpret CT scans
Correct answer: CT certification validates technical performance skills, not image interpretation or diagnosis
ARRT CT certification validates technical performance and patient care competencies; image interpretation and diagnosis remain within the radiologist's scope.
Question 22: In a CT perfusion study of the brain, which parameter measures the volume of blood in a given unit of brain tissue?
- Time to peak (TTP)
- Cerebral blood flow (CBF)
- Mean transit time (MTT)
- Cerebral blood volume (CBV) (Correct answer)
Correct answer: Cerebral blood volume (CBV)
Cerebral blood volume (CBV) represents the total volume of blood within a defined brain tissue volume, measured in mL/100g.
Question 23: A CT scan protocol using 'prospective ECG gating' for cardiac imaging acquires data only during which part of the cardiac cycle?
- Only during a pre-selected phase of diastole (Correct answer)
- Only during systole
- During both systole and diastole equally
- Throughout the entire R-R interval
Correct answer: Only during a pre-selected phase of diastole
Prospective ECG gating triggers X-ray exposure only during a selected quiescent diastolic window, substantially reducing radiation dose compared to retrospective gating.
Question 24: Which ACR-recommended CT quality control test should be performed if visual image artifacts are noted during clinical scanning?
- Reduce the scan FOV and repeat without QC evaluation
- Switch to a different reconstruction kernel and continue scanning
- Immediately repeat the patient scan at higher mAs
- Perform artifact analysis using an appropriate phantom and document findings before continuing clinical use (Correct answer)
Correct answer: Perform artifact analysis using an appropriate phantom and document findings before continuing clinical use
When clinical artifacts are observed, ACR guidelines require phantom-based artifact analysis and documentation before continuing patient scanning to ensure diagnostic image quality.
Question 25: Which phantom is used to measure CTDI100 according to the standard FDA/IEC protocol?
- A 32 cm diameter cylindrical PMMA phantom for head and a 16 cm phantom for body
- A 20 cm sphere filled with tissue-equivalent material
- A 16 cm diameter PMMA phantom for head and a 32 cm phantom for body (Correct answer)
- A water-filled anthropomorphic phantom
Correct answer: A 16 cm diameter PMMA phantom for head and a 32 cm phantom for body
The FDA/IEC protocol uses a 16 cm PMMA phantom for head measurements and a 32 cm phantom for body measurements to derive CTDI100.
Question 26: For a CT coronary angiography (CCTA) protocol, which heart rate range is generally ideal to minimize motion artifact?
- <65 bpm (Correct answer)
- >100 bpm
- 65–80 bpm
- 80–100 bpm
Correct answer: <65 bpm
Heart rates below 65 bpm allow longer diastolic rest periods, reducing cardiac motion artifact during CCTA acquisition.
Question 27: Within what timeframe must newly certified CT technologists complete their first renewal cycle?
- When their primary registration expires (Correct answer)
- One year from certification date
- Three years from certification date
- Two years from certification date
Correct answer: When their primary registration expires
Post-primary certification renewal is typically aligned with the technologist's primary registration renewal date, not a separate independent cycle.
Question 28: What is a Hounsfield unit?
- A unit of image resolution
- A measure of scan speed
- A unit of radiation dose
- A quantitative measurement of tissue density on CT images (Correct answer)
Correct answer: A quantitative measurement of tissue density on CT images
Hounsfield units (HU) measure tissue density on CT, with water at 0 HU, air at -1000 HU, and dense bone at +1000 HU or higher.
Question 29: Which factor is evaluated by the modulation transfer function (MTF) in CT quality control?
- CT number linearity
- Low-contrast detectability
- High-contrast spatial resolution (Correct answer)
- Image noise levels
Correct answer: High-contrast spatial resolution
The MTF describes how faithfully the CT system reproduces spatial detail, directly measuring high-contrast spatial resolution performance.
Question 30: The purpose of a body mechanics principle such as 'keeping the load close to the body' when lifting a patient is to:
- Protect the patient from falling
- Increase the speed of the transfer
- Reduce strain on the lumbar spine by minimizing torque (Correct answer)
- Maintain proper sterile field distance
Correct answer: Reduce strain on the lumbar spine by minimizing torque
Keeping a load close to the body reduces the moment arm and therefore the torque placed on the lumbar vertebrae, preventing injury.
Question 31: Aliasing artifacts in CT, which appear as fine streaks or Moiré patterns, are caused by which factor?
- Excessive patient size
- Insufficient detector sampling (Correct answer)
- High kVp settings
- Incorrect table speed
Correct answer: Insufficient detector sampling
Aliasing artifacts occur when the object being imaged contains spatial frequencies higher than the detector sampling rate can capture, per the Nyquist theorem.
Question 32: What is the purpose of contrast media in CT scans?
- To speed up the scan
- To reduce radiation dose
- To make the patient comfortable
- To enhance the visibility of specific structures and pathology (Correct answer)
Correct answer: To enhance the visibility of specific structures and pathology
Contrast media (dye) enhances the visibility of blood vessels, organs, and abnormalities by changing how X-rays interact with specific tissues.
Question 33: What does informed consent require?
- Family approval only
- Explaining the procedure, risks, benefits, and alternatives to the patient (Correct answer)
- Verbal agreement only
- Getting any signature on a form
Correct answer: Explaining the procedure, risks, benefits, and alternatives to the patient
Informed consent requires that patients understand the proposed procedure, its risks and benefits, alternatives, and have the opportunity to ask questions before agreeing.
Question 34: How does ARRT CT certification support a technologist's participation in quality improvement initiatives within their department?
- It disqualifies technologists from serving on quality committees
- It provides the advanced protocol and dose optimization knowledge needed to contribute meaningfully to QI projects (Correct answer)
- It only applies to patient scheduling improvements
- It transfers QI responsibilities entirely to the radiologist
Correct answer: It provides the advanced protocol and dose optimization knowledge needed to contribute meaningfully to QI projects
The depth of CT knowledge required for ARRT certification equips technologists to identify protocol inefficiencies, dose issues, and image quality problems in QI settings.
Question 35: The spatial frequency at which the MTF falls to 10% is commonly used to define:
- The noise power spectrum peak
- The detective quantum efficiency (DQE)
- The optimal reconstruction FOV
- The limiting spatial resolution of the CT system (Correct answer)
Correct answer: The limiting spatial resolution of the CT system
MTF10% represents the highest spatial frequency the system can transfer with 10% modulation, effectively defining the limiting resolution.
Question 36: Which employment sector has seen the fastest growth in demand for ARRT CT-certified technologists in recent years?
- Dental radiography offices
- Outpatient and freestanding imaging centers (Correct answer)
- Film-based radiology departments
- Veterinary imaging clinics
Correct answer: Outpatient and freestanding imaging centers
The rapid expansion of outpatient and freestanding imaging centers has driven increased demand for ARRT CT-certified technologists outside traditional hospital settings.
Question 37: An automatic exposure control (AEC) system in CT adjusts which parameter in real time?
- Tube current (mA) based on patient attenuation (Correct answer)
- Reconstruction kernel
- Detector row width
- Gantry rotation speed
Correct answer: Tube current (mA) based on patient attenuation
CT AEC (tube current modulation) automatically adjusts mA based on patient size and attenuation to maintain consistent image quality at optimal dose.
Question 38: The annual occupational dose limit for the lens of the eye, as updated by NCRP Report No. 172, is:
- 5 mSv
- 50 mSv
- 20 mSv (Correct answer)
- 150 mSv
Correct answer: 20 mSv
NCRP Report No. 172 (2016) lowered the recommended annual occupational lens dose limit to 20 mSv/year averaged over 5 years, consistent with ICRP 103.
Question 39: Which technique is most commonly used to reduce metal artifact in CT imaging of patients with hip prostheses?
- Using a smaller FOV
- Increasing slice thickness
- Metal artifact reduction (MAR) software (Correct answer)
- Decreasing kVp
Correct answer: Metal artifact reduction (MAR) software
Metal artifact reduction (MAR) algorithms replace corrupted projection data near metal with interpolated data, significantly reducing streaking artifacts.
Question 40: What is the first step in the ARRT CT certification process?
- Submit an online application through the ARRT portal (Correct answer)
- Complete the required clinical competencies
- Obtain a recommendation letter from an employer
- Schedule the CT certification exam
Correct answer: Submit an online application through the ARRT portal
The initial step in the ARRT CT certification process, after meeting all prerequisites, is to formally apply. This is done by submitting an online application through the official ARRT website portal. This application initiates the eligibility review and allows candidates to proceed with scheduling their exam.
Question 41: Quantum (photon) noise in CT images is most visible under which conditions?
- Low mAs or large patient size (Correct answer)
- Fast pitch and narrow FOV
- High kVp and wide window
- High mAs and thin slices
Correct answer: Low mAs or large patient size
Quantum noise increases when fewer photons reach the detectors, which occurs with low mAs settings or when X-rays are attenuated by a large patient.
Question 42: A candidate fails the ARRT CT examination. What is the minimum waiting period before their first retake?
- 1 year
- 2 weeks
- 6 months
- 3 months (Correct answer)
Correct answer: 3 months
ARRT requires a 3-month waiting period between examination attempts to allow candidates time for remediation.
Question 43: What is preventive maintenance?
- Regular scheduled maintenance to prevent equipment failure (Correct answer)
- Cleaning only
- Fixing equipment after it breaks
- Replacing all equipment annually
Correct answer: Regular scheduled maintenance to prevent equipment failure
Preventive maintenance involves regular, scheduled inspections and servicing to prevent unexpected breakdowns and extend equipment life.
Question 44: What does 'afterglow' (or 'ghosting') in CT solid-state detectors cause?
- Reduced spatial resolution due to detector cross-talk
- Increased image noise due to photon starvation
- Ring artifacts from a single failed detector channel
- Residual signal carried over from prior projections, causing streak artifacts (Correct answer)
Correct answer: Residual signal carried over from prior projections, causing streak artifacts
Afterglow occurs when scintillator crystals continue to emit light after X-ray exposure ends, carrying residual signal into subsequent projections and causing streak or shading artifacts.
Question 45: In multi-detector CT (MDCT), increasing the number of detector rows primarily allows:
- Elimination of pitch requirements
- Higher kVp settings
- Reduced x-ray tube heat loading per scan
- Simultaneous acquisition of more slices per rotation, improving z-axis coverage speed (Correct answer)
Correct answer: Simultaneous acquisition of more slices per rotation, improving z-axis coverage speed
More detector rows mean more slice data acquired per rotation, covering a larger anatomical volume per gantry revolution and reducing scan time.
Question 46: What is homeostasis?
- A type of cell division
- The body's ability to maintain stable internal conditions (Correct answer)
- An organ system
- A disease state
Correct answer: The body's ability to maintain stable internal conditions
Homeostasis is the body's dynamic process of maintaining stable internal conditions (temperature, pH, blood sugar) despite external changes.
Question 47: The windmill artifact seen in helical CT is most commonly associated with which acquisition parameter?
- Low kVp
- Small reconstruction FOV
- High pitch values (Correct answer)
- Large detector collimation
Correct answer: High pitch values
Windmill artifacts appear as alternating dark and bright streaks rotating around structures and are caused by the under-sampling that occurs at high pitch values.
Question 48: How many continuing education credits must ARRT-registered CT technologists earn during each 2-year renewal cycle?
- 36 credits
- 48 credits
- 24 credits (Correct answer)
- 12 credits
Correct answer: 24 credits
ARRT requires 24 Category A continuing education credits per 2-year renewal cycle for registered technologists.
Question 49: Which statement best describes an isotropic voxel in CT imaging?
- A voxel that contains only one tissue type
- A voxel with maximum attenuation value
- A voxel reconstructed using iterative algorithms
- A voxel with equal dimensions in x, y, and z axes (Correct answer)
Correct answer: A voxel with equal dimensions in x, y, and z axes
Isotropic voxels have equal measurements in all three spatial dimensions, enabling high-quality MPR and 3D reconstructions in any plane without stair-step degradation.
Question 50: Which of the following scenarios would trigger ARRT's mandatory ethics disclosure requirement?
- A technologist works per diem at multiple facilities
- A technologist changes their legal name
- A technologist receives a civil traffic violation
- A technologist is convicted of healthcare fraud (Correct answer)
Correct answer: A technologist is convicted of healthcare fraud
ARRT's Standards of Ethics require self-disclosure of criminal convictions, including healthcare fraud, within 30 days of the conviction.
Question 51: What is the recommended frequency for performing a full CT equipment performance evaluation by a qualified medical physicist?
- Annually (Correct answer)
- Every five years
- Weekly
- Daily
Correct answer: Annually
ACR and AAPM guidelines recommend a comprehensive CT performance evaluation by a qualified medical physicist at least annually.
Question 52: How many total attempts does ARRT allow a candidate to take the CT certification examination?
- 2 attempts
- Unlimited attempts
- 3 attempts (Correct answer)
- 5 attempts
Correct answer: 3 attempts
ARRT limits candidates to 3 total attempts to pass each post-primary examination, including CT.
Question 53: Windowing in CT (setting window width and level) affects:
- The spatial resolution of the image
- The actual CT numbers in the reconstructed data
- Radiation dose to the patient
- Only the display of contrast by mapping HU values to gray shades (Correct answer)
Correct answer: Only the display of contrast by mapping HU values to gray shades
Windowing is a display operation that maps selected HU ranges to the visible gray scale; it does not alter the underlying image data.
Question 54: What is the correct order for donning PPE?
- Any order is acceptable
- Mask, gloves, gown, eye protection
- Gloves, gown, mask, eye protection
- Gown, mask, eye protection, gloves (Correct answer)
Correct answer: Gown, mask, eye protection, gloves
The correct donning sequence is gown first, then mask/respirator, eye protection/face shield, and gloves last. This prevents contamination during application.
Question 55: A standard high-resolution CT (HRCT) chest protocol uses which reconstruction approach to evaluate interstitial lung disease?
- Thick slices with soft tissue kernel
- Thin slices with soft tissue kernel
- Thin slices with high-frequency (sharp) kernel (Correct answer)
- Thick slices with bone kernel
Correct answer: Thin slices with high-frequency (sharp) kernel
HRCT uses thin slices (≤1.5 mm) with a high-spatial-frequency kernel to maximize edge detail of lung parenchyma and airways.
Question 56: Which statement best describes the principle of informed consent?
- Consent is implied once the patient enters the radiology department
- The patient must be given a full explanation of the procedure, risks, benefits, and alternatives before voluntarily agreeing (Correct answer)
- The patient signs a form without needing a full explanation of the procedure
- Consent may be obtained by any staff member regardless of their role
Correct answer: The patient must be given a full explanation of the procedure, risks, benefits, and alternatives before voluntarily agreeing
Informed consent requires full disclosure of the procedure, risks, benefits, and alternatives so the patient can make a voluntary, knowledgeable decision.
Question 57: Which factor primarily determines the z-axis (longitudinal) resolution in a multislice CT scanner?
- Detector row width (Correct answer)
- Gantry rotation speed
- kVp setting
- Reconstruction matrix size
Correct answer: Detector row width
Z-axis resolution is primarily determined by detector row width (collimation), which defines slice thickness in the longitudinal direction.
Question 58: Regarding the ARRT CT eligibility requirement for moral character, which of the following is TRUE?
- Moral character is only evaluated after the examination is passed
- ARRT does not have a moral character requirement for post-primary certifications
- Candidates must attest to meeting ARRT Standards of Ethics at the time of application (Correct answer)
- Moral character requirements apply only to new graduates, not experienced technologists
Correct answer: Candidates must attest to meeting ARRT Standards of Ethics at the time of application
All ARRT applicants must attest to meeting the Standards of Ethics, including moral character, as part of the application process.
Question 59: Aliasing artifacts in CT most commonly occur due to:
- Overuse of iterative reconstruction
- Insufficient angular sampling of projection data (undersampling) (Correct answer)
- High patient body mass index
- Calibration errors in the slip ring
Correct answer: Insufficient angular sampling of projection data (undersampling)
Aliasing arises when the sampling rate of projection views is too low to accurately represent fine detail, producing Moiré-like or streak patterns.
Question 60: What does a noise index (NI) setting in automatic tube current modulation (ATCM) control?
- The target image noise level that drives mA adjustments (Correct answer)
- The amount of bowtie filter attenuation
- The maximum allowed kVp during the scan
- The number of reconstruction iterations applied
Correct answer: The target image noise level that drives mA adjustments
The noise index defines the target standard deviation of image noise; ATCM raises or lowers mA to achieve this noise target based on patient attenuation.
Question 61: Which statement BEST describes the relationship between CT noise and mAs?
- Noise is inversely proportional to mAs
- Noise is unaffected by mAs changes
- Noise is directly proportional to mAs
- Noise is proportional to 1/√mAs (Correct answer)
Correct answer: Noise is proportional to 1/√mAs
CT noise follows Poisson statistics; doubling mAs quadruples photons but only reduces noise by a factor of √2, making noise proportional to 1/√mAs.
Question 62: Partial volume averaging artifacts in CT are best reduced by which acquisition parameter adjustment?
- Increasing mAs
- Widening the display window
- Increasing kVp
- Using a thinner slice thickness (Correct answer)
Correct answer: Using a thinner slice thickness
Thinner slices reduce partial volume averaging by ensuring each voxel contains tissue from a smaller volume, improving accuracy of CT numbers.
Question 63: What are standard precautions in healthcare?
- Hand washing after patient contact only
- Only wearing gloves for known infections
- Using masks during surgery only
- Treating all blood and body fluids as potentially infectious (Correct answer)
Correct answer: Treating all blood and body fluids as potentially infectious
Standard precautions assume all blood and body fluids are potentially infectious, requiring consistent use of barriers (gloves, gowns, masks) and hand hygiene for all patient interactions.
Question 64: Which artifact appears as a dark band between two high-density objects on a CT image and is caused by beam hardening?
- Moiré artifact
- Ring artifact
- Windmill artifact
- Shadowing or 'dark band' artifact (Correct answer)
Correct answer: Shadowing or 'dark band' artifact
Dark bands (also called 'shadowing' or 'cupping' between dense objects) arise from extreme beam hardening where few low-energy photons survive to reach the detector between two dense structures.
Question 65: Curved planar reformation (CPR) in CT is most useful for:
- Straightening and displaying tortuous structures such as vessels or the spine along their entire length (Correct answer)
- Generating endoscopic views of hollow organs
- Creating color-coded perfusion maps
- Subtracting bone from CT angiography images
Correct answer: Straightening and displaying tortuous structures such as vessels or the spine along their entire length
CPR follows a user-defined curved path through the volume dataset to display a tortuous structure in a single unfolded plane, useful for coronary arteries or the aorta.
Question 66: Which of the following best describes a 'dual-phase' liver CT protocol?
- Portal venous and delayed phases only
- Non-contrast and delayed phases only
- Arterial and portal venous phases (Correct answer)
- Non-contrast and arterial phases only
Correct answer: Arterial and portal venous phases
A dual-phase liver protocol acquires images in both the hepatic arterial phase and the portal venous phase to characterize liver lesions.
Question 67: During a multi-phase CT liver protocol (non-contrast, arterial, portal venous, delayed), which action BEST reduces cumulative patient dose?
- Increase slice thickness per phase to reduce total acquisitions
- Eliminate phases not essential for the clinical indication and use dose modulation for each phase (Correct answer)
- Increase kVp for each phase to reduce noise
- Use the maximum mAs for all phases to guarantee image quality
Correct answer: Eliminate phases not essential for the clinical indication and use dose modulation for each phase
Eliminating unnecessary scan phases and applying tube current modulation to each remaining phase are the most effective strategies to reduce cumulative multi-phase CT dose.
Question 68: In CT, the term 'pitch' for single-slice CT is calculated as:
- kVp / mAs
- Table speed / gantry rotation time
- Detector width / field of view
- Table feed per rotation / slice thickness (Correct answer)
Correct answer: Table feed per rotation / slice thickness
Pitch = table feed per 360° rotation divided by the nominal slice thickness; a pitch >1 means gaps exist between consecutive slices.
Question 69: What type of artifact appears as bright or dark streaks radiating from high-density objects like metal implants in CT images?
- Ring artifact
- Motion artifact
- Beam hardening artifact (Correct answer)
- Partial volume artifact
Correct answer: Beam hardening artifact
Beam hardening artifacts appear as streaks or dark bands radiating from dense metallic objects because lower-energy photons are preferentially absorbed.
Question 70: When using bolus tracking for a contrast-enhanced CT aorta study, where is the region of interest (ROI) typically placed to trigger scanning?
- Descending aorta at the level of the diaphragm or ascending aorta (Correct answer)
- Left ventricle
- Pulmonary artery
- Inferior vena cava
Correct answer: Descending aorta at the level of the diaphragm or ascending aorta
For aortic CTA, the ROI for bolus tracking is placed in the aorta (ascending or at the diaphragm level) to trigger acquisition when contrast reaches the threshold HU.
Question 71: What are the four basic tissue types in the human body?
- Epithelial, connective, muscle, and nervous (Correct answer)
- Skin, bone, blood, and fat
- Brain, heart, lung, and liver
- Smooth, rough, dense, and loose
Correct answer: Epithelial, connective, muscle, and nervous
The four fundamental tissue types are epithelial (covering/lining), connective (support/connection), muscle (movement), and nervous (communication/control).
Question 72: A radiologic technologist holds R.T.(R)(CT) credentials. What do the letters in parentheses each represent?
- (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification (Correct answer)
- (R) = Radiology degree; (CT) = computed tomography license
- (R) = residency completed; (CT) = computed tomography board
- (R) = state registration; (CT) = federal CT permit
Correct answer: (R) = primary ARRT registration in Radiography; (CT) = post-primary CT certification
R.T.(R) denotes primary ARRT registration in Radiography, and (CT) denotes the additional post-primary CT certification earned.
Question 73: A CT technologist completes 30 Category A credits in one renewal cycle. How many, if any, credits can be carried over to the next cycle?
- 6 credits can be carried over
- All excess credits carry over automatically
- 12 credits can be carried over
- 0 credits — no carryover is allowed (Correct answer)
Correct answer: 0 credits — no carryover is allowed
ARRT does not allow Category A CE credits to be carried over from one renewal cycle to the next.
Question 74: What is the difference between arteries and veins?
- They carry the same blood in the same direction
- Arteries carry blood away from the heart; veins carry blood toward the heart (Correct answer)
- Veins are thicker than arteries
- Arteries are only in the lungs
Correct answer: Arteries carry blood away from the heart; veins carry blood toward the heart
Arteries carry blood away from the heart (usually oxygenated) while veins carry blood toward the heart (usually deoxygenated). Arteries have thicker walls to handle higher pressure.
Question 75: What is the function of red blood cells?
- To clot blood
- To fight infection
- To transport oxygen from lungs to tissues and CO2 back (Correct answer)
- To produce hormones
Correct answer: To transport oxygen from lungs to tissues and CO2 back
Red blood cells (erythrocytes) contain hemoglobin that binds oxygen in the lungs and delivers it to tissues, then carries carbon dioxide back for exhalation.
Question 76: What does OPSEC stand for?
- Operational Section
- Optional Security
- Operating System Executive
- Operations Security (Correct answer)
Correct answer: Operations Security
OPSEC protects critical information from adversaries by identifying and safeguarding sensitive data.
Question 77: For a CT abdomen/pelvis with IV contrast, what is the typical scan delay after contrast injection to capture the nephrographic phase of the kidneys?
- 10–15 seconds
- 25–35 seconds
- 80–120 seconds (Correct answer)
- 3–5 minutes
Correct answer: 80–120 seconds
The nephrographic phase occurs approximately 80–120 seconds post-injection, when the renal cortex and medulla enhance uniformly, optimizing detection of renal masses.
Question 78: What does the term 'detector efficiency' refer to in CT scanner performance?
- The number of detector rows in the system
- The speed at which the gantry rotates
- The FOV coverage per rotation
- The ability of detectors to capture and convert X-ray photons into usable signal (Correct answer)
Correct answer: The ability of detectors to capture and convert X-ray photons into usable signal
Detector efficiency describes how effectively CT detectors absorb incident X-ray photons and convert them into electrical signal, directly affecting image quality and dose.
Question 79: A starburst pattern of streaks emanating from the edge of the patient's shoulders during a neck CT is most likely caused by:
- Detector malfunction
- Gantry tilt error
- Incorrect windowing
- Beam hardening from bone and soft tissue interfaces (Correct answer)
Correct answer: Beam hardening from bone and soft tissue interfaces
Dense cortical bone at the shoulder causes beam hardening, producing characteristic streak artifacts that radiate into adjacent soft tissues.
Question 80: A 'blooming artifact' in CT most commonly results from:
- High-density metallic objects causing overestimation of structure size (Correct answer)
- Incorrect HU calibration of the scanner
- Patient motion during acquisition
- Undersampling of high-frequency data
Correct answer: High-density metallic objects causing overestimation of structure size
Blooming occurs when high-attenuation objects like metals or calcifications appear larger than their true size due to beam hardening and partial volume effects.
Question 81: A technologist holds both ARRT Radiography (R) and MRI (MR) credentials. To add CT certification, which credential serves as the qualifying primary pathway?
- Only Radiography (R) qualifies
- Both credentials must be listed; neither alone qualifies
- Only MRI (MR) qualifies
- Either R or MR can serve as the qualifying primary credential (Correct answer)
Correct answer: Either R or MR can serve as the qualifying primary credential
ARRT allows multiple qualifying primary pathways for CT, so either an active R or MR credential can serve as the qualifying base.
Question 82: What does CT stand for in medical imaging?
- Cardiac Testing
- Clinical Therapy
- Central Treatment
- Computed Tomography (Correct answer)
Correct answer: Computed Tomography
CT (Computed Tomography) uses X-ray technology and computer processing to create detailed cross-sectional images of the body.
Question 83: Which reconstruction kernel (filter) should be chosen to minimize noise when imaging soft tissue structures in the abdomen?
- Smooth or standard soft tissue kernel (Correct answer)
- Bone or edge-enhancing kernel
- Ultra-high resolution kernel
- Lung kernel
Correct answer: Smooth or standard soft tissue kernel
Soft tissue kernels apply low-pass filtering that smooths the image and reduces noise, which is appropriate for abdominal soft tissue evaluation.
Question 84: The ARRT Standards of Ethics is incorporated into the CT certification process primarily to:
- Assess candidates' academic GPA
- Ensure candidates demonstrate professional integrity and moral character (Correct answer)
- Verify candidates' financial standing
- Confirm candidates' insurance coverage
Correct answer: Ensure candidates demonstrate professional integrity and moral character
The Standards of Ethics screening ensures that only individuals with demonstrated professional integrity are certified.
Question 85: What is a Hounsfield unit?
- A unit of radiation dose
- A measure of scan speed
- A quantitative measurement of tissue density on CT images (Correct answer)
- A unit of image resolution
Correct answer: A quantitative measurement of tissue density on CT images
Hounsfield units (HU) measure tissue density on CT, with water at 0 HU, air at -1000 HU, and dense bone at +1000 HU or higher.
Question 86: An ARRT-certified CT technologist moves to a state that also requires state licensure for CT practice. Which statement is true?
- ARRT certification replaces all state licensing requirements
- State licensure CE requirements always mirror ARRT requirements exactly
- ARRT automatically notifies the state upon renewal
- State licensure and ARRT certification are separate and both may be required (Correct answer)
Correct answer: State licensure and ARRT certification are separate and both may be required
ARRT certification and state licensure are independent processes; meeting ARRT standards does not automatically satisfy state licensing requirements.
Question 87: When evaluating a CT image for streak artifacts emanating from a hip prosthesis, the BEST corrective technique is:
- Increasing the kVp to 140
- Decreasing the mAs by 50%
- Metal artifact reduction (MAR) reconstruction algorithm (Correct answer)
- Widening the reconstruction FOV
Correct answer: Metal artifact reduction (MAR) reconstruction algorithm
Metal artifact reduction algorithms use iterative or sinogram-based techniques to model and subtract metal-induced streaks from the image.
Question 88: In CT quality control, 'low-contrast detectability' refers to the system's ability to:
- Measure exact CT numbers for each tissue type
- Determine the maximum scan field of view
- Distinguish objects with small differences in attenuation from background (Correct answer)
- Resolve fine structural detail in bone
Correct answer: Distinguish objects with small differences in attenuation from background
Low-contrast detectability measures the scanner's ability to visualize objects with subtle attenuation differences, which is critical for soft-tissue diagnosis.
Question 89: Which CT quality control phantom is most commonly used to evaluate CT number accuracy, noise, uniformity, and spatial resolution?
- Alderson Rando phantom
- AAPM CT performance phantom (Correct answer)
- MOSFET dosimetry phantom
- Leeds TOR phantom
Correct answer: AAPM CT performance phantom
The AAPM CT performance phantom contains inserts for testing multiple image quality parameters including HU accuracy, noise, and spatial resolution.
Question 90: A technologist holds ARRT primary certification in Radiography and a post-primary in CT. How many total CE credits are required per cycle?
- 48 total — 24 for each credential separately
- 24 total, shared across both credentials (Correct answer)
- 24 total, with at least 6 specific to CT
- 36 total — 24 for primary plus 12 for post-primary
Correct answer: 24 total, shared across both credentials
ARRT allows the same 24 Category A CE credits to satisfy renewal requirements for both the primary and post-primary certifications simultaneously.
Question 91: What is the primary purpose of the CT dose index (CTDI)?
- To calculate the effective dose to the technologist
- To characterize radiation output of a CT scanner independent of patient size (Correct answer)
- To determine scatter radiation levels in the control room
- To measure patient absorbed dose in a single organ
Correct answer: To characterize radiation output of a CT scanner independent of patient size
CTDI characterizes the radiation output of a CT scanner and allows standardized comparison between scanners and protocols.
Question 92: The Hounsfield unit (HU) value of pure water is:
- -1000
- +1000
- +100
- 0 (Correct answer)
Correct answer: 0
By definition, pure water is assigned an HU value of 0 on the Hounsfield scale used in CT imaging.
Question 93: The 'noise power spectrum' (NPS) in CT characterizes noise by:
- Measuring total noise as a single RMS value
- Comparing noise before and after contrast injection
- Describing how noise energy is distributed across spatial frequencies (Correct answer)
- Counting the number of noisy pixels per slice
Correct answer: Describing how noise energy is distributed across spatial frequencies
The NPS (or Wiener spectrum) describes the frequency distribution of noise variance, distinguishing coarse (low-frequency) from fine (high-frequency) noise textures.
Question 94: Which of the following scan coverage ranges is standard for a CT of the abdomen and pelvis?
- Diaphragm to pubic symphysis (Correct answer)
- Diaphragm to iliac crests only
- Umbilicus to pubic symphysis
- Lung apices to pubic symphysis
Correct answer: Diaphragm to pubic symphysis
A standard abdomen and pelvis CT extends from the diaphragm superiorly to the pubic symphysis inferiorly to cover all abdominal and pelvic organs.
Question 95: What is the primary advantage of CT over conventional X-ray?
- CT uses no radiation
- CT is cheaper
- CT provides cross-sectional images with superior soft tissue contrast (Correct answer)
- CT takes less time
Correct answer: CT provides cross-sectional images with superior soft tissue contrast
CT provides detailed cross-sectional images with much better soft tissue contrast resolution than conventional X-rays, allowing visualization of subtle differences between tissues.
Question 96: Respiratory motion artifacts on chest CT can best be minimized by:
- Increasing kVp
- Widening the display window
- Using breath-hold technique during acquisition (Correct answer)
- Increasing slice thickness
Correct answer: Using breath-hold technique during acquisition
Instructing the patient to suspend respiration during CT acquisition eliminates breathing motion, preventing blurring and step artifacts in the chest.
Question 97: A contrast CT of the abdomen shows a 'whirl sign' in the mesentery. What condition does this indicate?
- Closed-loop small bowel obstruction with volvulus (Correct answer)
- Appendicitis
- Mesenteric adenitis
- Bowel perforation
Correct answer: Closed-loop small bowel obstruction with volvulus
The whirl sign on CT represents twisting of mesenteric vessels and bowel loops, indicating volvulus typically causing closed-loop obstruction.
Question 98: In CT quality control documentation, what is the purpose of establishing 'action limits' for QC measurements?
- To set thresholds that, when exceeded, require investigation and corrective action before clinical use (Correct answer)
- To determine the minimum number of QC tests per week
- To define the maximum patient dose per study
- To establish the contrast media injection rate limits
Correct answer: To set thresholds that, when exceeded, require investigation and corrective action before clinical use
Action limits define tolerance thresholds for QC parameters; if a measurement falls outside these limits, the scanner must be taken out of service for investigation and repair.
Question 99: A CT technologist retires and allows their ARRT registration to expire for 8 years, then wishes to return to practice. What is required?
- Retaking the ARRT CT certification examination (Correct answer)
- A letter of recommendation from a radiologist
- Completion of 24 CE credits and a reinstatement fee
- Submission of a reinstatement fee only
Correct answer: Retaking the ARRT CT certification examination
After an extended lapse beyond ARRT's reinstatement window, technologists are typically required to retake the certification examination to demonstrate current competency.
Question 100: Which type of CT detector material is most commonly used in modern multi-detector CT (MDCT) systems due to its high conversion efficiency and fast decay time?
- Gadolinium oxysulfide (GOS) solid-state scintillators (Correct answer)
- Xenon gas ionization chambers
- Sodium iodide (NaI) crystal detectors
- Bismuth germanate (BGO) crystals
Correct answer: Gadolinium oxysulfide (GOS) solid-state scintillators
Modern MDCT scanners predominantly use solid-state scintillator detectors such as gadolinium oxysulfide because of their high X-ray absorption efficiency and rapid afterglow decay.
Question 101: The spatial resolution of a CT image is primarily limited by which factor?
- Type of reconstruction filter used alone
- Room temperature
- Patient age
- Focal spot size and detector aperture (Correct answer)
Correct answer: Focal spot size and detector aperture
Focal spot size and detector cell aperture are the primary hardware factors limiting spatial resolution in CT.
Question 102: What is the application window for the ARRT CT post-primary examination after a candidate is deemed eligible?
- Six months from approval to test
- 30 days from approval to test
- Two years from approval to test
- One year from approval to test (Correct answer)
Correct answer: One year from approval to test
Once approved, ARRT candidates have one year to schedule and sit for the post-primary CT examination.
Question 103: A CT technologist is audited by ARRT and cannot produce records for completed CE activities. What is the most likely consequence?
- ARRT will contact the CE sponsors on their behalf
- A formal written warning is issued
- They are required to repeat the certification exam
- Their CE credits may be disallowed and registration revoked (Correct answer)
Correct answer: Their CE credits may be disallowed and registration revoked
During an audit, failure to document CE activities can result in disallowance of credits and potential revocation of registration.
Question 104: The dose length product (DLP) is calculated by multiplying CTDI_vol by which parameter?
- Scan length (cm) (Correct answer)
- Rotation time
- Number of detector rows
- Pitch factor
Correct answer: Scan length (cm)
DLP = CTDI_vol × scan length (cm), providing a single value that reflects the total radiation energy deposited during the scan.
Question 105: Which of the following would trigger an automatic review by the ARRT Ethics Review Committee?
- A program director retiring
- A technologist changing their employer
- A credential holder being convicted of a felony (Correct answer)
- A technologist failing to submit CE on time
Correct answer: A credential holder being convicted of a felony
A felony conviction is a serious ethics matter that ARRT's Ethics Review Committee must evaluate to determine whether the credential can be maintained.
Question 106: What is the difference between arteries and veins?
- Veins are thicker than arteries
- They carry the same blood in the same direction
- Arteries are only in the lungs
- Arteries carry blood away from the heart; veins carry blood toward the heart (Correct answer)
Correct answer: Arteries carry blood away from the heart; veins carry blood toward the heart
Arteries carry blood away from the heart (usually oxygenated) while veins carry blood toward the heart (usually deoxygenated). Arteries have thicker walls to handle higher pressure.
Question 107: Which of the following BEST describes noise power spectrum (NPS) in CT?
- A measure of how noise is distributed across spatial frequencies in an image (Correct answer)
- A test of detector linearity across HU ranges
- The ratio of signal to total detector noise
- The standard deviation of HU values in a uniform phantom
Correct answer: A measure of how noise is distributed across spatial frequencies in an image
NPS characterizes the frequency content of image noise, showing whether noise is more granular (high-frequency) or blotchy (low-frequency) depending on reconstruction parameters.
Question 108: What is the role of the bowtie (beam-shaping) filter in CT equipment operation?
- To equalize X-ray flux across the fan beam, reducing dose at the periphery and minimizing detector saturation (Correct answer)
- To collimate the beam to the prescribed slice thickness
- To harden the beam and remove low-energy photons uniformly across the beam
- To increase photon energy for improved tissue penetration
Correct answer: To equalize X-ray flux across the fan beam, reducing dose at the periphery and minimizing detector saturation
The bowtie filter is thicker at the edges and thinner at the center, compensating for the cylindrical shape of patients to equalize detector flux and reduce peripheral skin dose.
Question 109: For a pancreatic protocol CT, which phase is most critical for detecting hypervascular pancreatic neuroendocrine tumors?
- Unenhanced phase
- Portal venous phase at 70 seconds
- Late arterial (pancreatic parenchymal) phase at 40–50 seconds (Correct answer)
- Delayed phase at 5 minutes
Correct answer: Late arterial (pancreatic parenchymal) phase at 40–50 seconds
Pancreatic neuroendocrine tumors are hypervascular and enhance most conspicuously during the pancreatic parenchymal phase (approximately 40–50 seconds), when the pancreas peaks in enhancement.
Question 110: Which of the following primary credentials does NOT qualify a technologist to sit for the ARRT CT post-primary examination?
- Radiation Therapy (T)
- Chiropractic (DACBR) (Correct answer)
- Nuclear Medicine Technology (N)
- Radiography (R)
Correct answer: Chiropractic (DACBR)
Chiropractic radiology is not an ARRT-recognized qualifying primary pathway for CT post-primary eligibility.
Question 111: The Hounsfield unit (HU) value of pure water is defined as:
- +1000 HU
- +500 HU
- -1000 HU
- 0 HU (Correct answer)
Correct answer: 0 HU
The CT number scale defines water as 0 HU and air as −1000 HU, with other tissues placed relative to these references.
Question 112: To meet ARRT’s ethics requirements, which of the following is necessary?
- Agree to follow the ARRT Standards of Ethics and report any potential violations (Correct answer)
- Take a separate ethics exam during the certification process
- Submit a personal statement of professional ethics
- Pass a background check and provide character references
Correct answer: Agree to follow the ARRT Standards of Ethics and report any potential violations
The ARRT places a strong emphasis on ethical conduct within the radiologic technology profession. To meet their ethics requirements, candidates must formally agree to adhere to the ARRT Standards of Ethics, which outline professional responsibilities and conduct. This commitment includes reporting any potential violations, upholding the integrity of the profession.
Question 113: A technologist is scanning a patient with metal hip implants. To reduce dose while managing metal artifact, which approach is MOST appropriate?
- Skip the hip region entirely regardless of clinical indication
- Double the mAs in the hip region to overpower artifacts
- Use metal artifact reduction (MAR) software at standard dose rather than routinely increasing mAs (Correct answer)
- Switch to a lower kVp to increase contrast resolution
Correct answer: Use metal artifact reduction (MAR) software at standard dose rather than routinely increasing mAs
Metal artifact reduction software effectively manages implant artifacts at standard dose; routinely increasing mAs adds unnecessary patient dose without eliminating artifacts.
Question 114: Which window setting is most appropriate for evaluating pulmonary nodules in the lung parenchyma?
- Window width ~1500 HU, window level ~-600 HU (Correct answer)
- Window width ~400 HU, window level ~40 HU
- Window width ~3000 HU, window level ~300 HU
- Window width ~200 HU, window level ~80 HU
Correct answer: Window width ~1500 HU, window level ~-600 HU
Lung windows use a wide width (~1500 HU) and negative level (~-600 HU) to display the full range of lung attenuation from air to soft tissue.
Question 115: What is the ALARA principle in radiation safety?
- As Low As Reasonably Achievable — minimize radiation exposure (Correct answer)
- Automated Limiting Adjustment for Radiation Applications
- All Labs And Rooms Assessed
- Always Lock And Restrict Access
Correct answer: As Low As Reasonably Achievable — minimize radiation exposure
ALARA means keeping radiation doses as low as reasonably achievable while still obtaining diagnostic-quality images, balancing benefit against risk.
Question 116: A candidate who completed a structured education program in radiologic technology but has not yet passed their primary certification exam may:
- Apply for CT immediately after graduation
- Not apply for CT until the primary credential is active and unrestricted (Correct answer)
- Apply for CT under a provisional license
- Apply for CT if supervised by a radiologist
Correct answer: Not apply for CT until the primary credential is active and unrestricted
Candidates must hold an active, unrestricted primary credential before applying for the CT post-primary examination.
Question 117: ARRT certification in CT is best described as which type of credential?
- Entry-level primary certification
- Post-primary specialty certification (Correct answer)
- Academic degree credential
- State-issued license
Correct answer: Post-primary specialty certification
CT certification is a post-primary specialty credential, meaning it is layered on top of a primary ARRT certification in a related discipline.
Question 118: A CT scan for appendicitis in a young female patient of childbearing age should be preceded by:
- Double dose of IV contrast
- Administration of glucagon
- Evaluation for pregnancy and consideration of alternative imaging (Correct answer)
- Lung window reconstruction
Correct answer: Evaluation for pregnancy and consideration of alternative imaging
Radiation dose to a fetus is a critical concern; pregnancy should be assessed and ultrasound or MRI considered as alternatives before CT in reproductive-age females.
Question 119: When performing a CT pulmonary angiography (CTPA), which scan direction is preferred?
- Caudal to cranial (Correct answer)
- Bidirectional
- Cranial to caudal
- Either direction equally
Correct answer: Caudal to cranial
Caudal-to-cranial scanning in CTPA ensures the densest contrast bolus reaches the pulmonary arteries during image acquisition.
Question 120: A patient with a serum creatinine of 1.8 mg/dL is scheduled for a contrast-enhanced CT. Which action is most appropriate?
- Proceed normally with standard iodinated contrast dose
- Switch to gadolinium-based contrast agent
- Cancel the exam entirely without further evaluation
- Notify the radiologist and consider pre-hydration protocols (Correct answer)
Correct answer: Notify the radiologist and consider pre-hydration protocols
Elevated creatinine indicates impaired renal function, requiring radiologist notification and consideration of pre-hydration or dose reduction to minimize contrast-induced nephropathy risk.
Question 121: What is the primary radiation hazard associated with CT compared to conventional radiography?
- Higher peak kilovoltage
- Use of radioactive isotopes as contrast agents
- Greater secondary radiation reaching personnel in adjacent rooms
- Significantly greater patient dose due to multiple rotational acquisitions and extended scan volumes (Correct answer)
Correct answer: Significantly greater patient dose due to multiple rotational acquisitions and extended scan volumes
CT delivers substantially higher patient doses than conventional radiography because it involves multiple rotational X-ray acquisitions covering large anatomical volumes.
Question 122: Increasing the x-ray tube voltage (kVp) in CT primarily results in:
- Higher image noise and lower contrast
- Unchanged image quality but increased scan time
- Lower mean photon energy and higher subject contrast
- Higher mean photon energy and reduced photoelectric interactions (Correct answer)
Correct answer: Higher mean photon energy and reduced photoelectric interactions
Higher kVp produces a higher mean photon energy beam with greater penetrating power; Compton scatter dominates over photoelectric effect, reducing subject contrast.
Question 123: On CT of the head, lenticular (biconvex) hyperdensity is identified adjacent to the temporal bone. What is the most likely cause?
- Hypertensive hemorrhage
- Middle meningeal artery rupture causing epidural hematoma (Correct answer)
- Berry aneurysm rupture
- Bridging vein rupture causing subdural hematoma
Correct answer: Middle meningeal artery rupture causing epidural hematoma
Epidural hematomas result from middle meningeal artery injury and form a biconvex hyperdense collection limited by dural attachments at sutures.
Question 124: Iterative reconstruction (IR) techniques in CT offer which primary advantage over filtered back projection?
- Faster reconstruction speed
- Reduced image noise at the same or lower radiation dose (Correct answer)
- Elimination of all artifacts
- Higher spatial resolution
Correct answer: Reduced image noise at the same or lower radiation dose
IR algorithms use repeated mathematical modeling of the imaging process to suppress noise, allowing diagnostic image quality to be maintained at reduced mAs and dose.
Question 125: For a trauma CT protocol of the chest, which contrast phase is typically acquired?
- Non-contrast only
- Arterial phase only
- Portal venous phase (Correct answer)
- Delayed phase only
Correct answer: Portal venous phase
The portal venous phase (~60–70 seconds post-injection) provides optimal parenchymal enhancement to detect solid organ injuries in chest trauma.
Question 126: In CT, contrast-to-noise ratio (CNR) is BEST described as:
- The difference in HU between two structures divided by image noise (Correct answer)
- The number of line pairs per centimeter resolved
- The ability to detect objects of varying sizes
- The ratio of signal to detector dark current
Correct answer: The difference in HU between two structures divided by image noise
CNR = (HU_structure − HU_background) ÷ noise standard deviation, quantifying how well a structure stands out against background noise.
Question 127: Multiplanar reformation (MPR) in CT refers to:
- Applying color to CT images based on Hounsfield units
- Generating 3D surface models from volumetric data
- Reconstructing axial images into coronal, sagittal, or oblique planes (Correct answer)
- Subtracting pre-contrast from post-contrast images
Correct answer: Reconstructing axial images into coronal, sagittal, or oblique planes
MPR uses the volumetric CT dataset to create reformatted images in any anatomical plane without additional radiation exposure to the patient.
Question 128: Which of the following best describes an out-of-field artifact in CT?
- Streaking caused by anatomy extending beyond the scan FOV (Correct answer)
- Noise from low mAs
- Blurring from respiratory motion
- Ring caused by detector failure
Correct answer: Streaking caused by anatomy extending beyond the scan FOV
Out-of-field artifacts occur when part of the patient's anatomy lies outside the calibrated scan FOV, causing truncation of projection data and bright peripheral streaks.
Question 129: When creating coronal MPR images from a helical chest CT, image quality is best when the original acquisition used:
- Thin slices (≤1 mm) reconstructed at overlapping intervals (0.5–0.7 mm) (Correct answer)
- Thick slices (5–10 mm) reconstructed at 5 mm intervals
- High pitch with standard soft tissue kernel only
- Large FOV and minimal overlap
Correct answer: Thin slices (≤1 mm) reconstructed at overlapping intervals (0.5–0.7 mm)
Thin, overlapping reconstructions produce near-isotropic voxels that allow high-quality coronal and sagittal reformations without visible stair-step artifacts.
Question 130: A CT technologist notices the dose reference level (DRL) for a routine chest CT is being routinely exceeded. The BEST first step is to:
- Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality (Correct answer)
- Continue scanning since DRLs are not legally binding limits
- Report the finding only to the radiologist and take no further action
- Immediately halve the mAs for all chest CT exams
Correct answer: Review and optimize the scan protocol to determine if dose can be reduced without compromising diagnostic quality
DRLs serve as benchmarks; exceeding them triggers a protocol review to identify optimization opportunities while preserving diagnostic image quality.
Question 131: A patient weighing 300 lbs is scanned using a standard adult protocol. How should the technologist respond?
- Use pediatric technique factors
- Reduce mAs by 50% regardless of image quality
- Increase kVp to 140 and decrease mAs proportionally
- Apply size-specific dose estimates (SSDE) and adjust technique for body habitus (Correct answer)
Correct answer: Apply size-specific dose estimates (SSDE) and adjust technique for body habitus
SSDE accounts for patient size and provides a more accurate dose estimate; technique should be adjusted to match body habitus while maintaining diagnostic quality.
Question 132: A ring or band artifact centered on the image is most likely caused by a malfunction of which CT component?
- Collimator
- A single detector element (Correct answer)
- X-ray tube
- Gantry motor
Correct answer: A single detector element
Ring artifacts result from a miscalibrated or malfunctioning detector element producing a circular artifact at a fixed radius from the isocenter.
Question 133: When a CT abdomen protocol specifies 'nephrographic phase,' scanning typically occurs at what delay after IV contrast injection?
- 5–10 minutes
- 80–120 seconds (Correct answer)
- 30–45 seconds
- 15–25 seconds
Correct answer: 80–120 seconds
The nephrographic phase occurs at approximately 80–120 seconds post-injection when both cortex and medulla enhance uniformly, optimizing renal parenchymal visualization.
Question 134: Increasing the reconstruction field of view (FOV) while keeping matrix size constant will:
- Increase pixel size and decrease spatial resolution (Correct answer)
- Increase noise while improving contrast
- Decrease pixel size and increase spatial resolution
- Have no effect on spatial resolution
Correct answer: Increase pixel size and decrease spatial resolution
Larger FOV with the same matrix means each pixel covers more area, increasing pixel size and reducing spatial resolution.
Question 135: On axial CT of the abdomen, the superior mesenteric artery (SMA) is typically located:
- Within the hepatoduodenal ligament
- Posterior to the splenic vein
- Directly anterior to the abdominal aorta, surrounded by fat (Correct answer)
- Lateral to the inferior vena cava
Correct answer: Directly anterior to the abdominal aorta, surrounded by fat
The SMA arises from the anterior aorta and is typically seen as a vessel surrounded by a halo of mesenteric fat on axial CT.
Question 136: In CT, the filtered back projection (FBP) reconstruction algorithm applies a mathematical filter primarily to:
- Correct for star artifacts inherent in simple back projection (Correct answer)
- Align misregistered projection data
- Segment soft tissue from bone
- Remove quantum noise before reconstruction
Correct answer: Correct for star artifacts inherent in simple back projection
FBP applies a ramp or other convolution filter to projection data before back-projecting to eliminate the blurring ('star artifact') produced by simple back projection.
Question 137: Which CT image quality parameter is measured using a modulation transfer function (MTF)?
- Contrast resolution
- Temporal resolution
- Spatial resolution (Correct answer)
- Noise power spectrum
Correct answer: Spatial resolution
The MTF quantifies spatial resolution by describing how faithfully the CT system reproduces objects of varying spatial frequencies.
Question 138: What physiologic mechanism underlies contrast-induced nephropathy (CIN)?
- Systemic vasodilation leading to prerenal azotemia
- Obstructive uropathy from contrast precipitation in the collecting ducts
- Immune-mediated glomerulonephritis triggered by iodine
- Renal medullary ischemia and direct tubular cell toxicity from contrast (Correct answer)
Correct answer: Renal medullary ischemia and direct tubular cell toxicity from contrast
CIN results from renal medullary vasoconstriction causing ischemia combined with direct cytotoxic effects of contrast on tubular epithelial cells.
Question 139: Which vital sign finding in an adult patient should be reported to the supervising clinician before proceeding with a routine radiographic exam?
- Blood pressure of 118/76 mmHg
- Temperature of 98.6°F (37°C)
- Pulse of 72 beats per minute
- Respiratory rate of 10 breaths per minute (Correct answer)
Correct answer: Respiratory rate of 10 breaths per minute
A respiratory rate of 10 breaths per minute is below the normal range (12-20) and indicates bradypnea, which warrants clinical notification.
Question 140: A CT chest in a patient with AIDS shows bilateral ground-glass opacities in a 'bat-wing' distribution. The most likely diagnosis is:
- Pneumocystis jirovecii pneumonia (Correct answer)
- Mycobacterium avium complex
- Cytomegalovirus pneumonitis
- Kaposi sarcoma
Correct answer: Pneumocystis jirovecii pneumonia
PCP (Pneumocystis jirovecii pneumonia) classically presents with bilateral perihilar ground-glass opacities in immunocompromised patients.
Question 141: Which reconstruction field of view (FOV) is most appropriate when performing targeted high-resolution CT of the temporal bone?
- 10–15 cm (small targeted FOV) (Correct answer)
- 40 cm (large FOV)
- 25 cm (medium FOV)
- 50 cm (full body FOV)
Correct answer: 10–15 cm (small targeted FOV)
A 10–15 cm reconstruction FOV over the temporal bone maximizes pixel density within the small region of interest, yielding the highest possible spatial resolution.
Question 142: CT perfusion imaging requires specialized post-processing to generate which type of parametric maps?
- Standardized uptake value (SUV) maps
- Cerebral blood flow, cerebral blood volume, and mean transit time maps (Correct answer)
- Bone mineral density scores
- Hounsfield unit histograms
Correct answer: Cerebral blood flow, cerebral blood volume, and mean transit time maps
CT perfusion post-processing applies deconvolution or maximum slope models to time-attenuation curves to produce quantitative maps of CBF, CBV, and MTT.
Question 143: A patient states, 'I am Jehovah's Witness and refuse any blood transfusion.' The radiologic technologist should:
- Contact the patient's family to override the decision
- Disregard the statement as the patient may not understand their condition
- Proceed with the procedure and allow physicians to decide later
- Document the statement and notify the supervising clinician immediately (Correct answer)
Correct answer: Document the statement and notify the supervising clinician immediately
A competent adult patient has the right to refuse treatment; the technologist must document this and notify the care team to ensure informed refusal is properly handled.
Question 144: The window level (WL) in CT display refers to:
- The minimum threshold for bone segmentation
- The center Hounsfield unit value of the displayed grayscale range (Correct answer)
- The total range of Hounsfield units shown
- The reconstruction matrix size
Correct answer: The center Hounsfield unit value of the displayed grayscale range
Window level sets the midpoint of the HU range being displayed, determining which tissue densities appear as medium gray on the monitor.
Question 145: What is the maximum number of times a candidate may attempt the ARRT CT examination?
- Unlimited attempts within the eligibility window
- 6 times total (Correct answer)
- No limit on attempts, but a new application is required after 3 failures
- 3 times total
Correct answer: 6 times total
ARRT allows a maximum of 6 examination attempts for any given credential.
Question 146: What is one key reason that ACR-accredited imaging facilities value technologists with ARRT CT certification?
- Accreditation requires a minimum ratio of 10 certified techs per scanner
- ACR accreditation prohibits hiring uncertified technologists
- ARRT CT certification is issued by the ACR
- Certified technologists help demonstrate staff qualifications required during ACR accreditation reviews (Correct answer)
Correct answer: Certified technologists help demonstrate staff qualifications required during ACR accreditation reviews
ACR accreditation reviewers assess staff qualifications, and ARRT CT certification is recognized evidence of competency that supports accreditation approval.
Question 147: A CT technologist with ARRT CT certification wants to teach at a community college radiologic technology program. How does the certification help?
- It only qualifies the technologist to teach radiography, not CT specifically
- It is a disqualifying credential for educational roles
- It automatically grants a teaching license in all states
- It demonstrates content expertise that many programs require or prefer for adjunct CT instructors (Correct answer)
Correct answer: It demonstrates content expertise that many programs require or prefer for adjunct CT instructors
Community college and vocational radiologic technology programs often require or prefer instructors to hold advanced ARRT credentials in the specialty they are teaching.
Question 148: Which pitch factor would result in the longest scan time for a given scan range?
- 2.0
- 1.5
- 1.0
- 0.5 (Correct answer)
Correct answer: 0.5
A lower pitch means the table moves more slowly relative to rotation speed, resulting in more overlap and a longer scan time.
Question 149: For a pediatric CT head scan, compared to an adult protocol, the technologist should generally:
- Increase kVp to 140 kV to penetrate the skull
- Reduce mAs significantly because children are more radiosensitive and smaller (Correct answer)
- Use the same mAs to ensure adequate image quality
- Extend scan length to cover the entire neuraxis
Correct answer: Reduce mAs significantly because children are more radiosensitive and smaller
Children have greater radiosensitivity and smaller body dimensions, so pediatric CT protocols use substantially lower mAs than adult protocols.
Question 150: During a CT pulmonary angiography, the technologist notices extravasation of contrast at the injection site. What is the first action?
- Increase the injection pressure to maintain flow
- Switch to a new injection site and restart the injection
- Continue the injection at a slower rate
- Stop the injection immediately and notify the radiologist (Correct answer)
Correct answer: Stop the injection immediately and notify the radiologist
Extravasation can cause tissue injury; the injection must be stopped immediately and the radiologist informed for proper management.
Question 151: A Radiation Therapy (T) credential holder who wishes to obtain CT certification must complete which category of clinical competencies?
- Radiography general competencies only
- CT-specific competencies as outlined in the ARRT CT content specifications (Correct answer)
- MRI competencies as a prerequisite
- No clinical competencies — written exam only
Correct answer: CT-specific competencies as outlined in the ARRT CT content specifications
All CT candidates, regardless of their primary pathway, must satisfy CT-specific clinical competency requirements.
Question 152: A horizontal band of decreased attenuation passing through the posterior fossa on a head CT is a classic example of which artifact?
- Motion artifact from cardiac pulsation
- Ring artifact
- Beam hardening between the petrous bones (Correct answer)
- Partial volume artifact
Correct answer: Beam hardening between the petrous bones
The dense petrous temporal bones cause preferential absorption of lower-energy photons, producing a dark band across the posterior fossa known as a beam hardening artifact.
Question 153: A CT abdomen in a trauma patient shows high-density fluid in the hepatorenal space (Morison's pouch). What does this indicate?
- Hemoperitoneum (Correct answer)
- Biliary leak
- Lymphocele
- Physiologic peritoneal fluid
Correct answer: Hemoperitoneum
High-attenuation free fluid (>30 HU) in Morison's pouch following trauma indicates hemoperitoneum from solid organ or vascular injury.
Question 154: What is the primary purpose of the ARRT's preapplication review process?
- To expedite exam scheduling for experienced technologists
- To waive the examination fee for qualified applicants
- To substitute for clinical competency documentation
- To allow individuals with potential ethics issues to determine eligibility before investing in education (Correct answer)
Correct answer: To allow individuals with potential ethics issues to determine eligibility before investing in education
The preapplication review lets individuals with past ethical issues get a preliminary ruling on eligibility before completing an educational program.
Question 155: The pitch value in helical CT is defined as:
- Slice thickness divided by detector row width
- Gantry rotation speed divided by table speed
- Table travel per rotation divided by total beam collimation width (Correct answer)
- kVp divided by mA
Correct answer: Table travel per rotation divided by total beam collimation width
Pitch = table distance traveled per 360° rotation ÷ total collimated beam width, and values >1 indicate gaps in data coverage.
Question 156: What is the NATO phonetic alphabet letter for 'B'?
- Boy
- Bravo (Correct answer)
- Beta
- Baker
Correct answer: Bravo
In the NATO phonetic alphabet, 'B' is represented by 'Bravo.' This ensures clear radio communication.
Question 157: On a CT image at the level of C6, which structure occupies the anterior midline of the neck?
- Common carotid artery
- Esophagus
- Trachea
- Thyroid gland (Correct answer)
Correct answer: Thyroid gland
The thyroid gland wraps anteriorly around the trachea at the C5-C6 level, occupying the anterior midline.
Question 158: On axial CT at the level of L4-L5, which structure is found anterior to the vertebral body?
- Celiac axis
- Inferior mesenteric artery origin
- Superior mesenteric artery origin
- Abdominal aortic bifurcation (Correct answer)
Correct answer: Abdominal aortic bifurcation
The abdominal aorta bifurcates into the common iliac arteries at approximately the L4 vertebral level.
Question 159: Which of the following best explains why ARRT periodically revises its CT examination content specifications?
- To match content used by competing certification bodies
- To increase examination difficulty and reduce pass rates
- To satisfy JRCERT annual audit requirements
- To align the examination with evolving clinical practice identified through practice analysis (Correct answer)
Correct answer: To align the examination with evolving clinical practice identified through practice analysis
ARRT updates content specifications based on practice analysis data to ensure examinations reflect what entry-level technologists actually need to know in current clinical settings.
Question 160: Which scan phase best demonstrates hepatic metastases that are hypervascular?
- Portal venous phase
- Delayed phase
- Hepatic arterial phase (Correct answer)
- Non-contrast phase
Correct answer: Hepatic arterial phase
Hypervascular metastases enhance avidly during the hepatic arterial phase when liver parenchyma enhancement is low, maximizing lesion-to-liver contrast.
Question 161: Which career pathway is most directly opened by holding ARRT CT certification?
- Lead CT technologist or CT supervisor (Correct answer)
- Radiology billing and coding specialist
- Radiation oncology physician assistant
- Nuclear medicine physician
Correct answer: Lead CT technologist or CT supervisor
CT certification establishes the specialized credential often required for leadership roles such as lead CT tech or CT department supervisor.
Question 162: What is the largest organ in the human body?
- Brain
- Liver
- Heart
- Skin (Correct answer)
Correct answer: Skin
The skin is the largest organ, covering approximately 20 square feet in adults and weighing about 8 pounds. It serves as the primary barrier against the environment.
Question 163: CT of the abdomen in a cirrhotic patient shows multiple enhancing nodules in the liver. Which additional finding would most strongly suggest hepatocellular carcinoma over regenerative nodules?
- Washout appearance on delayed phase imaging (Correct answer)
- Nodule size less than 1 cm
- Homogeneous enhancement in all phases
- T2 hypointensity on MRI
Correct answer: Washout appearance on delayed phase imaging
Arterial enhancement followed by washout on portal venous or delayed phase is the LI-RADS CT hallmark distinguishing HCC from benign regenerative nodules.
Question 164: What does CT stand for in medical imaging?
- Clinical Therapy
- Computed Tomography (Correct answer)
- Central Treatment
- Cardiac Testing
Correct answer: Computed Tomography
CT (Computed Tomography) uses X-ray technology and computer processing to create detailed cross-sectional images of the body.
Question 165: On a sagittal CT reconstruction of the chest, the azygos vein is best identified by its arch over which structure?
- The right main bronchus (Correct answer)
- The superior vena cava
- The left main bronchus
- The right pulmonary artery
Correct answer: The right main bronchus
The azygos vein arches over the right main bronchus before draining into the posterior superior vena cava.
Question 166: When transferring a patient from a wheelchair to the radiographic table, the wheelchair should be positioned at what angle relative to the table?
- 45 degrees (Correct answer)
- 90 degrees
- Parallel and touching the table
- 180 degrees
Correct answer: 45 degrees
Positioning the wheelchair at approximately 45 degrees to the table allows the shortest, most controlled pivot transfer for the patient.
Question 167: When comparing filtered back projection (FBP) to model-based iterative reconstruction (MBIR) at matched noise levels, MBIR typically demonstrates:
- Lower spatial resolution but equivalent noise
- Equivalent resolution but increased beam hardening artifacts
- Higher spatial resolution with fewer artifacts at lower dose (Correct answer)
- Longer reconstruction times with no image quality advantage
Correct answer: Higher spatial resolution with fewer artifacts at lower dose
MBIR models the entire imaging chain including optics and statistics, achieving better resolution and artifact suppression at lower dose than FBP.
Question 168: CT of the neck in a patient with a palpable mass shows a cystic lesion at the angle of the mandible deep to the sternocleidomastoid muscle. This is most consistent with:
- Branchial cleft cyst (Correct answer)
- Lymphatic malformation
- Dermoid cyst
- Thyroglossal duct cyst
Correct answer: Branchial cleft cyst
Branchial cleft cysts characteristically appear as unilocular cystic masses at the angle of the mandible adjacent to the sternocleidomastoid muscle.
Question 169: The 'noise' measured in a CT image is quantified as:
- The standard deviation of CT numbers in a uniform region of interest (Correct answer)
- The mean CT number in a region of interest
- The difference between maximum and minimum CT numbers in the image
- The number of image artifacts present
Correct answer: The standard deviation of CT numbers in a uniform region of interest
Image noise in CT is quantified as the standard deviation of HU values within a uniform phantom region; higher standard deviation indicates greater noise.
Question 170: Which of the following best describes the CT appearance of the caudate lobe of the liver?
- A small segment located between the IVC and the fissure for the ligamentum venosum (Correct answer)
- Located posterior to the inferior vena cava and anterior to the portal vein
- The largest segment of the left hepatic lobe
- Located between the gallbladder fossa and the fissure for the ligamentum teres
Correct answer: A small segment located between the IVC and the fissure for the ligamentum venosum
The caudate lobe (segment I) lies between the IVC posteriorly and the fissure for the ligamentum venosum anteriorly.
Question 171: Automatic tube current modulation (ATCM) in CT primarily aims to:
- Maintain consistent image noise while minimizing patient dose (Correct answer)
- Eliminate motion artifacts in cardiac imaging
- Improve temporal resolution in dynamic studies
- Maximize image spatial resolution for all body regions
Correct answer: Maintain consistent image noise while minimizing patient dose
ATCM adjusts mA based on patient attenuation in real time, delivering higher current through thicker/denser regions to maintain uniform noise and reducing dose elsewhere.
Question 172: CT window width (WW) setting controls which aspect of image display?
- The overall brightness of the image
- The center Hounsfield unit of the gray scale
- The spatial resolution of the image
- The range of Hounsfield units displayed as the full gray scale from black to white (Correct answer)
Correct answer: The range of Hounsfield units displayed as the full gray scale from black to white
Window width determines the range of CT numbers (HU) mapped to the grayscale; a narrow window increases contrast but limits the HU range displayed.
Question 173: What is the window level and window width on CT images?
- Physical measurements of the CT scanner
- Patient positioning parameters
- Scan speed controls
- Settings that control the brightness and contrast of displayed images (Correct answer)
Correct answer: Settings that control the brightness and contrast of displayed images
Window level sets the center brightness (what HU appears as middle gray) and window width controls contrast range (how many HUs span from black to white).
Question 174: Which document must a CT examination candidate submit to verify completion of required clinical experience?
- A personal statement of clinical hours
- An IRS tax form showing employment
- Attestation signed by the supervising radiologist or program director (Correct answer)
- A letter from the hospital CEO
Correct answer: Attestation signed by the supervising radiologist or program director
ARRT requires an attestation from a qualified supervisor verifying that the candidate met clinical competency requirements.
Question 175: The ARRT CT examination is delivered at:
- ARRT headquarters only
- Pearson VUE testing centers (Correct answer)
- Accredited radiologic technology schools
- Online via live proctoring from any location
Correct answer: Pearson VUE testing centers
ARRT partners with Pearson VUE to administer the CT post-primary examination at authorized testing centers.
Question 176: Which CT parameter most directly controls the amount of radiation dose delivered to the patient?
- Reconstruction kernel
- kVp
- mAs (Correct answer)
- Pitch
Correct answer: mAs
mAs (milliampere-seconds) directly determines the number of X-ray photons produced and is the primary controller of patient dose.
Question 177: What documentation does an ARRT candidate typically need to submit to verify clinical competency in CT?
- Competency verification signed by a supervising radiologist or qualified technologist (Correct answer)
- Employer payroll records
- ACR accreditation certificate of the facility
- A letter from the state radiology board
Correct answer: Competency verification signed by a supervising radiologist or qualified technologist
Clinical competency must be verified by a supervising qualified professional who can attest that the candidate performed required procedures.
Question 178: Quantum mottle in CT images is primarily caused by:
- Excessive table speed
- An insufficient number of detected photons (Correct answer)
- Detector calibration errors
- High kVp beam hardening
Correct answer: An insufficient number of detected photons
Quantum mottle (noise) occurs when too few photons reach the detector, causing statistical fluctuations that appear as grainy image texture.
Question 179: 3D volume rendering of CT data allows the display of internal structures through which technique?
- Subtracting bone from the dataset
- Selecting only the highest attenuation voxel per projection ray
- Applying a smooth kernel to the raw data
- Assigning opacity values to voxels based on their Hounsfield units (Correct answer)
Correct answer: Assigning opacity values to voxels based on their Hounsfield units
Volume rendering assigns transfer functions that map each HU value to a color and opacity, allowing semi-transparent visualization of multiple tissue types simultaneously.
Question 180: Which measurement best quantifies the amount of iodine delivered to a patient per unit time during a CT angiography injection?
- Iodine concentration in mg/mL alone
- Injection pressure in PSI
- Total contrast volume in mL
- Iodine delivery rate (IDR) expressed as grams of iodine per second (Correct answer)
Correct answer: Iodine delivery rate (IDR) expressed as grams of iodine per second
Iodine delivery rate (IDR = concentration [mgI/mL] × flow rate [mL/s]) determines the rate of iodine reaching the vascular system and predicts enhancement quality better than volume alone.
Question 181: CT of the knee shows a hyperdense line through the distal femoral epiphysis crossing the growth plate. This finding represents:
- Stress fracture
- Salter-Harris type II fracture (Correct answer)
- Osteochondral defect
- Physeal bar formation
Correct answer: Salter-Harris type II fracture
A Salter-Harris type II fracture extends through the physis and exits through the metaphysis, the most common physeal injury type.
Question 182: Which window setting is most appropriate for evaluating acute intracranial hemorrhage on a non-contrast head CT?
- Bone window (WW 2000, WL 300)
- Soft tissue window (WW 400, WL 50)
- Lung window (WW 1500, WL -500)
- Brain window (WW 80, WL 35) (Correct answer)
Correct answer: Brain window (WW 80, WL 35)
The brain window (narrow width ~80 HU, level ~35 HU) provides optimal contrast between hyperdense blood and surrounding brain tissue.
Question 183: A CT image shows ring artifacts. The MOST likely cause is:
- Patient motion during scanning
- Incorrect kVp selection
- Too low an mAs setting
- A malfunctioning or miscalibrated detector element (Correct answer)
Correct answer: A malfunctioning or miscalibrated detector element
Ring artifacts appear as circular bands centered on the isocenter and are caused by a single detector element producing consistently incorrect readings.
Question 184: What is the correct technique for removing contaminated gloves to prevent self-contamination?
- Pull both gloves off by the fingertips simultaneously
- Snap gloves off at the wrist and discard immediately
- Wash gloves with soap and water before removal
- Peel one glove inside-out from the wrist, then use bare fingers inside the second glove's wrist to remove it (Correct answer)
Correct answer: Peel one glove inside-out from the wrist, then use bare fingers inside the second glove's wrist to remove it
The proper technique keeps contaminated outer surfaces folded inside during removal so bare skin never contacts the contaminated exterior.
Question 185: A patient asks the radiologic technologist about the radiation dose they will receive from a CT scan. The best response is to:
- Dismiss the concern since modern CT scanners are considered completely safe
- Provide a general explanation of the dose and the benefit-risk balance while referring detailed questions to the radiologist (Correct answer)
- Tell the patient the dose information is confidential
- Explain that CT doses are too complex to explain to patients
Correct answer: Provide a general explanation of the dose and the benefit-risk balance while referring detailed questions to the radiologist
Patients have the right to understand their radiation exposure; the technologist should provide a clear, honest explanation and involve the radiologist for detailed clinical questions.
Question 186: A patient with a cardiac pacemaker presents for chest CT. Which artifact should the technologist anticipate?
- Cupping artifact
- Ring artifact
- Metallic streak artifact from the pacemaker leads and generator (Correct answer)
- Windmill artifact
Correct answer: Metallic streak artifact from the pacemaker leads and generator
Pacemaker generators and leads are highly attenuating metallic objects that produce characteristic beam hardening streak artifacts on chest CT.
Question 187: The primary interaction of diagnostic x-ray photons with soft tissue in CT is:
- Compton scattering (Correct answer)
- Pair production
- Photoelectric effect
- Coherent (Rayleigh) scattering
Correct answer: Compton scattering
At the diagnostic energy range used in CT (typically 80–140 kVp), Compton scattering is the dominant interaction in soft tissue.
Question 188: A CT technologist is concerned about cumulative occupational dose. Which dosimeter provides the most accurate record of whole-body exposure?
- Electronic personal dosimeter worn at waist
- Pocket ionization chamber
- Finger ring TLD
- Optically stimulated luminescence (OSL) badge worn at collar level (Correct answer)
Correct answer: Optically stimulated luminescence (OSL) badge worn at collar level
An OSL badge worn at the collar (outside any lead apron) is the standard for whole-body occupational dose monitoring and provides accurate cumulative records.
Question 189: Stochastic effects of radiation are characterized by which of the following?
- Occurring only in radiosensitive tissues such as bone marrow
- A threshold dose below which the effect cannot occur
- Severity increasing proportionally with dose above the threshold
- No dose threshold; probability of occurrence increases with dose (Correct answer)
Correct answer: No dose threshold; probability of occurrence increases with dose
Stochastic effects (e.g., radiation-induced cancer) are assumed to have no threshold; their probability, not severity, increases with dose.
Question 190: When performing a CT colonography, the technologist selects a 0.625 mm detector row width versus 5 mm. This change PRIMARILY improves:
- Contrast resolution for soft tissue differentiation
- Patient dose efficiency
- Longitudinal (z-axis) spatial resolution enabling multiplanar reformats (Correct answer)
- Temporal resolution for cardiac gating
Correct answer: Longitudinal (z-axis) spatial resolution enabling multiplanar reformats
Thinner detector rows provide finer z-axis sampling, enabling isotropic voxels and high-quality multiplanar reformats for polyp detection.
Question 191: A patient with a suspected C-spine injury is brought to the radiology department. Which method of moving the patient's head and neck is appropriate?
- Hyperextend the neck to open the airway
- Log-roll the patient independently
- Use a pillow for comfort and proceed
- Manual in-line stabilization at all times (Correct answer)
Correct answer: Manual in-line stabilization at all times
Manual in-line stabilization of the cervical spine must be maintained at all times to prevent further injury until the injury is ruled out.
Question 192: What is the primary advantage of CT over conventional X-ray?
- CT is cheaper
- CT provides cross-sectional images with superior soft tissue contrast (Correct answer)
- CT uses no radiation
- CT takes less time
Correct answer: CT provides cross-sectional images with superior soft tissue contrast
CT provides detailed cross-sectional images with much better soft tissue contrast resolution than conventional X-rays, allowing visualization of subtle differences between tissues.
Question 193: Which of the following is required as proof of identity when a candidate checks in for the ARRT CT examination?
- ARRT membership card only
- Government-issued photo ID with signature (Correct answer)
- Social Security card
- Employer-issued badge
Correct answer: Government-issued photo ID with signature
Pearson VUE and ARRT require a valid, unexpired government-issued photo ID with a matching signature at check-in.
Question 194: Which factor related to ARRT CT certification most directly contributes to long-term job security for a radiologic technologist?
- Employers cannot legally terminate certified employees
- Certified technologists are more difficult to replace, increasing their value during staffing reductions (Correct answer)
- ARRT monitors all employer actions against certified staff
- Certification guarantees tenure after three years of employment
Correct answer: Certified technologists are more difficult to replace, increasing their value during staffing reductions
Certified specialists are harder to replace than generalists, making them more valuable to departments and more likely to be retained during organizational changes.
ARRT Computed Tomography (CT) Certification Examination
The ARRT CT certification exam assesses entry-level knowledge and cognitive skills required for computed tomography practice, covering patient care, radiation safety, image production, and CT imaging procedures across all major anatomical regions.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong — answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds