Installation Techniques & Methods Flashcards
7 cards from real AIC practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Installation Techniques & Methods flashcards as text
Under the RCSC Specification, what defines the snug-tight condition of a bolted joint?
Answer: The plies are in firm contact, reached with a few impacts of an impact wrench or the full effort of an ironworker using an ordinary spud wrench
Snug-tight means the plies are in firm contact, reached with a few wrench impacts or full spud-wrench effort.
How does the turn-of-nut method pretension high-strength bolts?
Answer: By rotating the nut a specified amount past the snug-tight condition
Turn-of-nut controls tension through a specified nut rotation past snug-tight, often marked with match marks.
OSHA 1926 Subpart R requires column base connections to have at least how many anchor rods (bolts)?
Answer: Four
OSHA steel erection rules require a minimum of four anchor rods per column for stability during erection.
Metal floor and roof deck is most commonly attached to steel supporting members by which method?
Answer: Arc spot (puddle) welds or powder-actuated/screw fasteners
Steel deck is usually fastened with arc spot (puddle) welds or with mechanical fasteners such as powder-actuated pins or screws.
In multistory concrete construction, what is reshoring?
Answer: Placing shores under a slab after the original forms and shores have been removed
Reshores are placed after stripping to support young slabs and spread construction loads to the floors below.
How does a direct tension indicator (DTI) washer show adequate bolt pretension?
Answer: Its protrusions compress until the gap is reduced to a specified feeler-gage refusal
DTI protrusions flatten under bolt tension, and installers check the remaining gap with a feeler gage.
In post-tensioned concrete, when are the tendons typically stressed?
Answer: After the concrete reaches a specified minimum strength
Tendons are stressed once the concrete reaches the specified strength, often around 3,000 psi, verified by test cylinders.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- aic-builds.org — Test delivery, late registration, test dates, renewal, eligibility, fees, exam format, time limit, exam information · verified Oct 2026