Inhibitor & Water Treatment Flashcards

6 cards from real CENWAT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Inhibitor & Water Treatment flashcards as text
  1. What is a system cleanser (flush chemical) used for?

    Answer: To break down and remove sludge, scale and corrosion products during a power flush or chemical flush

    System cleansers (e.g., Fernox F3 or Sentinel X400) are dosed into the system water to loosen and dissolve sludge, scale and corrosion deposits, which are then removed during a power flush.

  2. What is a scale inhibitor and when is it particularly important?

    Answer: A chemical or physical device that reduces limescale formation, particularly important in hard water areas

    Scale inhibitors (e.g., polyphosphate dosers or chemical scale reducers) are used in hard water areas to prevent limescale from forming on heat exchanger surfaces, maintaining efficiency and preventing premature failure.

  3. What is the water hardness level above which a scale inhibitor or water softener is typically recommended for a boiler?

    Answer: Above 200 mg/l (as CaCO3) or as specified by the boiler manufacturer

    Most boiler manufacturers and industry guidance (e.g., HHIC, BS 7593) recommend scale protection measures when the water hardness exceeds 200 mg/l (20 Clarke degrees), which is common in south-east England.

  4. What standard provides guidance on water treatment in central heating systems?

    Answer: BS 7593

    BS 7593 (Code of practice for treatment of water in domestic hot water central heating systems) provides guidance on flushing, inhibitor dosing, water quality and maintenance of central heating system water.

  5. What is antifreeze and when is it used in a central heating system?

    Answer: A glycol-based additive that lowers the freezing point of system water, used in vulnerable systems such as holiday homes or systems with external pipework

    Antifreeze (typically propylene glycol based for heating systems) is added to system water to prevent freezing in vulnerable systems such as holiday cottages, or where external or unheated pipework runs are present.

  6. What precaution must be taken when using antifreeze in a central heating system with a combi boiler?

    Answer: Check the boiler manufacturer's approval — some plate heat exchangers can be damaged by glycol, and the DHW circuit must be protected from contamination

    Combi boilers use a plate heat exchanger where the primary (heating) circuit is in close proximity to potable water; glycol contamination of the DHW circuit is a health risk, so manufacturer guidance must always be checked.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. euskills.co.uk — Eligibility, test delivery, exam information · verified Oct 2026
  2. gassaferegister.co.uk — Renewal, score validity · verified Oct 2026