  1. What is the required minimum distance between a flue terminal and the ground level in a publicly accessible location?

    Answer: 2100 mm (2.1 m)

    Where a flue terminal is at low level in a publicly accessible area, it must be at least 2100 mm above the ground or guarded with a terminal guard to prevent burns or blockage.

  2. What is a terminal guard and when must it be fitted?

    Answer: A mesh guard fitted over a flue terminal when it is at low level or where it could be touched or blocked

    A terminal guard is required when a flue terminal could be touched, blocked or damaged — typically at low level or in areas accessible to the public; it must not restrict flue gas flow.

  3. What is a 'Type C' gas appliance classification?

    Answer: A room-sealed appliance with both air supply and flue gas ducts connected to the outside

    Under European classification, Type C (or category C) appliances are room-sealed with both combustion air and flue gas ducts connected directly to the outside atmosphere.

  4. What is the minimum free area of permanent ventilation required for an open-flued gas appliance of 10 kW input rating?

    Answer: As specified in BS 5440-2, typically 5 cm² per kW for a rated input above 7 kW (so approximately 15 cm² plus 5 cm² per kW above 7 kW)

    BS 5440-2 specifies ventilation requirements for open-flued appliances; the formula gives the minimum permanent vent area based on the appliance heat input to ensure adequate combustion air.

  5. What action should a Gas Safe engineer take if they find a CO alarm sounding at a property?

    Answer: Evacuate the property, call the gas emergency number, ventilate, investigate for source of CO before re-occupying

    A sounding CO alarm must be treated as a genuine emergency: evacuate all occupants, ventilate the property, call the gas emergency number (0800 111 999), and do not re-enter until cleared by a competent engineer.

  6. What standard specifies requirements for the installation of gas flues in domestic buildings?

    Answer: BS 5440-1

    BS 5440-1 covers flues and ventilation for gas appliances of rated input not exceeding 70 kW in domestic buildings, specifying design and installation requirements for flue systems.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. euskills.co.uk — Eligibility, test delivery, exam information · verified Oct 2026
  2. gassaferegister.co.uk — Renewal, score validity · verified Oct 2026