Flue Requirements & Pressure Relief Flashcards
6 cards from real CENWAT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Flue Requirements & Pressure Relief flashcards as text
If a PRV repeatedly discharges on a sealed central heating system, what is the most likely cause?
Answer: Waterlogged or failed expansion vessel
Repeated PRV discharge usually indicates a waterlogged or failed expansion vessel that can no longer absorb system expansion, causing pressure to rise and exceed the PRV set point on every heat cycle.
How should the expansion vessel on a sealed system be checked?
Answer: Turn off and drain the system, check and adjust the pre-charge pressure of the expansion vessel using a tyre pressure gauge to match the system cold fill pressure
The expansion vessel must be tested with the system drained (or isolated and water pressure released on the vessel side) by checking the nitrogen pre-charge pressure and recharging to the system cold fill pressure if low.
What is the purpose of a filling loop on a sealed central heating system?
Answer: To allow the system to be filled or topped up with mains water to the correct cold fill pressure
A filling loop provides a temporary connection between the cold mains supply and the heating system, allowing water to be introduced to achieve the correct cold fill pressure. It must be disconnected after use.
Why must a filling loop be disconnected after use?
Answer: To prevent backflow from the heating system contaminating the mains water supply
A connected filling loop could create a direct connection between the (contaminated) heating system water and the potable mains supply, risking backflow contamination — it must be disconnected to provide an air gap.
What pressure should a sealed system be set to when cold (before heating)?
Answer: As specified by the boiler manufacturer, typically 1–1.5 bar
The cold fill pressure is set per the manufacturer's recommendation, typically 1–1.5 bar, which allows the pressure to rise safely as the system heats up without reaching the PRV set point.
What is a safety valve test procedure for a sealed system PRV?
Answer: Manually lift the test lever briefly to confirm the valve opens and reseats correctly, then check for signs of weeping
The PRV is tested by briefly lifting the test lever to confirm it opens and reseats; if the valve weeps after testing it may need replacement as debris can prevent proper reseating.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- euskills.co.uk — Eligibility, test delivery, exam information · verified Oct 2026
- gassaferegister.co.uk — Renewal, score validity · verified Oct 2026