Commissioning and Fault Finding Flashcards
6 cards from real CENWAT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 Commissioning and Fault Finding flashcards as text
During the commissioning of a sealed central heating system, what should the cold fill pressure typically be set to?
Answer: 1.0-1.5 bar
The cold fill pressure for a sealed domestic central heating system should typically be set between 1.0 and 1.5 bar when the system is cold. This provides sufficient pressure for operation while allowing headroom for expansion when the water heats up, typically rising to 1.5-2.0 bar.
What does a high CO/CO2 ratio reading during combustion analysis typically indicate?
Answer: Incomplete combustion, possibly due to insufficient air supply or burner fault
A high CO/CO2 ratio indicates incomplete combustion where the gas is not burning fully and producing excess carbon monoxide instead of carbon dioxide. Common causes include insufficient air supply, a dirty or damaged burner, incorrect gas pressure, or a blocked heat exchanger.
When commissioning a condensing boiler, what is the expected flue gas temperature when the boiler is operating in condensing mode?
Answer: Below 57 degrees C
When a condensing boiler is operating in full condensing mode, the flue gas temperature should be below the dew point of approximately 57 degrees C. At this temperature, water vapour in the combustion products condenses on the secondary heat exchanger, releasing latent heat.
What is the most likely cause of a sealed central heating system that keeps losing pressure over time with no visible leaks?
Answer: The expansion vessel has lost its air charge or the diaphragm has failed
When a sealed system loses pressure without visible leaks, the most common cause is a failed expansion vessel. Without proper expansion absorption, the pressure relief valve operates when the system heats up, discharging small amounts of water each cycle. The system then shows low pressure when cold.
What instrument is used to measure the gas burner pressure (working pressure) at a boiler?
Answer: A manometer or digital pressure gauge connected to the burner pressure test point
A manometer or calibrated digital pressure gauge is connected to the burner pressure test point on the gas valve to measure the working pressure. For natural gas, the normal burner pressure is typically 10-14 mbar depending on the manufacturer.
During balancing of a central heating system, which radiator should be balanced first?
Answer: The radiator nearest to the boiler
When balancing a heating system, you start with the radiator nearest to the boiler by partially closing its lockshield valve, then work progressively outward to the furthest radiator which should have its lockshield valve fully open. The aim is to achieve a consistent temperature drop of typically 11-12 degrees C across each radiator.
How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy
Sources & references
Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy
- euskills.co.uk — Eligibility, test delivery, exam information · verified Oct 2026
- gassaferegister.co.uk — Renewal, score validity · verified Oct 2026