Commissioning and Fault Finding Flashcards

6 cards from real CENWAT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Commissioning and Fault Finding flashcards as text
  1. A customer reports that radiators are hot at the top but cold at the bottom. What is the most likely cause?

    Answer: Sludge (magnetite) accumulation at the bottom of the radiators

    Radiators that are hot at the top but cold at the bottom typically indicate a build-up of iron oxide sludge at the bottom of the radiator. The sludge settles due to gravity and restricts water flow through the lower sections. Treatment involves a system powerflush or removal and manual flushing of affected radiators.

  2. What is the correct gas operating pressure (working pressure) at the meter for natural gas in the UK?

    Answer: 21 mbar

    The standard operating pressure for natural gas at the meter outlet in the UK is 21 mbar with a tolerance of plus or minus 2 mbar, so 19-23 mbar is acceptable. If the working pressure drops below 19 mbar with all appliances running, this indicates a problem with the gas supply.

  3. A condensing boiler is cycling on and off frequently (short cycling). What is the most likely cause?

    Answer: The system is oversized for the heat demand, or circulation is restricted

    Short cycling typically occurs when the boiler reaches its set temperature too quickly, either because the boiler is oversized for the property heat demand or because circulation is restricted with TRVs closed on most radiators without an adequate bypass. Solutions include checking the bypass valve and verifying boiler modulation range.

  4. What should you check first if a room thermostat is calling for heat but the boiler does not fire?

    Answer: Check the electrical connections, fuse spur, and whether the motorised valve end switch is making

    If the thermostat is calling for heat but the boiler does not fire, the first step is to check the electrical circuit. Verify the fused spur is on, check wiring connections, and critically check if the motorised valve is opening and its end switch is making. If the valve does not fully open, the end switch will not close the circuit to energise the boiler.

  5. When conducting a gas tightness test on a domestic central heating installation, what is the acceptable pressure drop over the test period?

    Answer: Zero pressure drop, no drop is permitted

    A gas tightness test on a domestic installation requires zero pressure drop over the prescribed test period. The system is pressurised to 20 mbar on the installation side of the meter and monitored. Any pressure drop indicates a leak that must be found and repaired.

  6. What does it indicate if a flue gas analyser shows oxygen readings significantly higher than expected, for example above 9%?

    Answer: There is excess air entering the combustion chamber or a flue leak

    Significantly elevated O2 readings in the flue gas indicate excess air in the combustion process. This can be caused by a cracked heat exchanger, a poorly sealed flue connection, incorrect burner pressure, or damaged seals. Excess air reduces efficiency and can mask dangerous CO levels by diluting them.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. euskills.co.uk — Eligibility, test delivery, exam information · verified Oct 2026
  2. gassaferegister.co.uk — Renewal, score validity · verified Oct 2026
Commissioning and Fault Finding Flashcards — CENWAT Study Cards with Answers