  1. What is the acceptable CO/CO2 ratio in flue gas for a correctly adjusted natural gas boiler?

    Answer: Below 0.004

    A CO/CO2 ratio below 0.004 indicates efficient and complete combustion in a correctly adjusted natural gas boiler; a ratio above 0.004 indicates incomplete combustion requiring investigation.

  2. What is the correct working gas pressure for natural gas at a domestic appliance inlet, measured while the appliance is operating at full load?

    Answer: 20 mbar

    The working pressure for natural gas at a domestic appliance inlet should be 20 mbar when measured with the appliance operating at full load, slightly below the 21 mbar standing pressure.

  3. When commissioning an open-flued gas appliance, which test confirms that the flue is performing correctly and removing combustion products safely?

    Answer: A spillage test using a smoke match or smoke pellet

    A spillage test using a smoke match or smoke pellet placed near the draught diverter confirms that combustion products are being safely drawn up and out of the flue rather than spilling into the room.

  4. What should an engineer do if a gas appliance cannot achieve the correct working pressure during commissioning?

    Answer: Do not commission the appliance and investigate the cause of the low pressure

    An appliance that cannot achieve its design working pressure must not be commissioned, as incorrect gas pressure leads to incomplete combustion, poor efficiency, and potentially dangerous operating conditions.

  5. What is the primary reference document for setting the correct burner pressure on a gas appliance during commissioning?

    Answer: The appliance manufacturer's installation instructions

    The appliance manufacturer's installation instructions specify the exact burner pressure settings for that appliance, and these must always be followed during commissioning as they are specific to each appliance design.

  6. What must an engineer do immediately if a CO alarm activates during the commissioning of a gas appliance?

    Answer: Shut off the appliance immediately and investigate the cause

    If a CO alarm activates during commissioning, the appliance must be immediately shut off and the cause fully investigated before any further work proceeds, as carbon monoxide is an odourless, potentially fatal gas.

  7. What percentage of CO2 would you typically expect in the flue gases of a correctly adjusted natural gas boiler?

    Answer: 7–9%

    A correctly adjusted natural gas boiler running with the appropriate amount of excess air should produce approximately 7–9% CO2 in the flue gases, indicating efficient combustion.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. igem.org.uk — Eligibility, test delivery, score validity, exam information · verified Nov 2026
  2. niceic.com — Exam format, renewal, retake policy · verified Oct 2026