← All CCN1 Flashcard Decks

Pipework Installation & Tightness Testing Flashcards

6 cards from real CCN1 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 Pipework Installation & Tightness Testing flashcards as text
  1. What is the purpose of a gas meter bypass?

    Answer: It is not a legitimate installation component — a bypass around a gas meter is illegal as it allows gas use without metering

    There is no legitimate purpose for a bypass around a gas meter in a domestic installation. Creating or using a meter bypass is a criminal offence as it enables theft of gas and creates serious safety risks.

  2. What is a 'pressure governor' (regulator) in a domestic gas installation and where is it located?

    Answer: A device that reduces the high pressure from the gas main to the lower working pressure (typically 20-21 mbar) required by domestic appliances — located at or in the meter assembly

    The pressure governor (regulator) is part of the meter assembly. It reduces the gas supply pressure from the higher distribution main pressure to the lower working pressure (approximately 20-21 mbar) required by domestic appliances.

  3. What must a Gas Safe engineer check when installing new gas pipework?

    Answer: That it is correctly sized, properly supported, uses approved materials and jointing methods, is tested for tightness, and is correctly identified

    New pipework installation requires correct sizing, proper mechanical support at specified intervals, use of approved materials and jointing methods, a tightness test of the completed pipework, and correct identification (labelling or marking).

  4. What is the correct jointing method for copper gas pipework?

    Answer: Compression fittings or capillary (solder) fittings approved for gas use — never push-fit plastic fittings

    Copper gas pipework may be joined with compression fittings or capillary solder fittings that are approved for gas use. Push-fit plastic fittings approved for water are NOT suitable for gas. Approved fittings must carry the relevant British Standard marking.

  5. At what intervals must copper gas pipework be supported (clipped) in a domestic installation?

    Answer: Every 1.2 metres for horizontal runs and every 1.8 metres for vertical runs (15 mm copper) — per BS 6891

    BS 6891 specifies support intervals for domestic gas installations. For 15 mm copper pipe, supports are required at maximum 1.2 m intervals on horizontal runs and 1.8 m on vertical runs. Correct support prevents sagging and joint stress.

  6. What is a CSST (Corrugated Stainless Steel Tubing) and what special installation consideration applies?

    Answer: A flexible stainless steel gas pipework system — requires specific bonding and must be installed in accordance with the manufacturer's instructions to prevent static discharge ignition

    CSST is a flexible stainless steel gas piping system. It requires specific bonding (electrical earthing) to prevent static electricity accumulation, which could in extreme cases cause ignition. Manufacturer's installation instructions must be followed precisely.

How this page was made: written with AI tools and published by Nathan Beja, founder of Practice Test Geeks, who is responsible for its content. Exam facts are checked against the official sources listed below. Not reviewed by a subject-matter expert. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. igem.org.uk — Eligibility, test delivery, score validity, exam information · verified Nov 2026
  2. niceic.com — Exam format, renewal, retake policy · verified Oct 2026