When OSHA Table 1 controls are not fully implemented for a silica-generating task, what must the employer do?
Answer: Assess employee exposure and limit it to the PEL
Employers not following Table 1 must use exposure assessment and keep exposures at or below the PEL.
Under the OSHA silica standard, what must an employer's written exposure control plan include?
Answer: Tasks involving silica exposure and the controls used for each
The plan must describe the tasks, engineering controls, work practices, and respiratory protection used.
Which tool practice best reduces silica dust when blowing out an anchor hole?
Answer: Use a HEPA vacuum or dust extraction instead of dry-sweeping or open blowing where permitted by the MPII
Capturing dust with HEPA extraction limits exposure while still achieving required hole cleanliness.
What is a key safety concern when installing adhesive anchors overhead?
Answer: Adhesive or debris falling into the eyes and face
Overhead work exposes the installer to falling dust and adhesive, requiring eye and face protection.
Before drilling into an existing concrete slab or wall, which hazard check is most important for compliance and safety?
Answer: Locate embedded conduits, post-tensioning tendons, and rebar
Striking tendons, live conduits, or rebar can cause injury and structural damage.
An installer notices the ambient and base material temperature is below the MPII's minimum installation temperature. What should be done?
Answer: Do not install until conditions meet MPII limits or follow approved conditioning procedures
Installing outside qualified temperature ranges can prevent proper cure and strength.
Which power tool safety device is required on construction sites for temporary electrical receptacles under OSHA?
Answer: Ground-fault circuit interrupter (GFCI) protection or an assured grounding program
OSHA 1926.404 requires GFCIs or an assured equipment grounding conductor program for temporary power.