← All AAI Flashcard Decks

Mixed Deck — All AAI Topics Flashcards

100 cards from real AAI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 20 Mixed Deck — All AAI Topics flashcards as text
  1. The installer has drawings marked "Rev. 1" but the field office has "Rev. 3" posted. Which should be used?

    Answer: The latest issued revision, Rev. 3

    Work must follow the most current approved revision to avoid installing to superseded information.

  2. What is the relationship between Project Planning & Scheduling and ethical professional conduct?

    Answer: Ethical considerations are integrated into all aspects of professional practice in this area

    Ethical considerations are deeply integrated into Project Planning & Scheduling, as professional conduct and integrity underpin all aspects of practice in this field.

  3. What is a key electrical advantage of using a cordless drill for anchor hole drilling?

    Answer: It removes cord damage and cord-related shock hazards from the work area

    Battery tools remove the extension cord, eliminating cord damage and associated shock and trip hazards.

  4. What federal agency enforces workplace hazard communication requirements for adhesive anchor installers?

    Answer: OSHA

    OSHA enforces the Hazard Communication Standard, 29 CFR 1910.1200.

  5. The minimum concrete member thickness for adhesive anchor installation is typically specified as a function of:

    Answer: The embedment depth and anchor diameter as specified in the MPII or evaluation report

    Minimum member thickness is typically specified as a multiple of embedment depth (e.g., h_ef + some clearance) and anchor diameter per the product's evaluation report or MPII.

  6. How does Mechanical Systems & Maintenance contribute to overall professional effectiveness?

    Answer: It provides essential knowledge and skills that directly impact quality of work and outcomes

    Mechanical Systems & Maintenance directly contributes to professional effectiveness by providing essential knowledge and skills that improve the quality of work and outcomes across all career levels.

  7. Which anchor elements are commonly installed with adhesive anchor systems?

    Answer: Threaded rod and deformed reinforcing bar

    Adhesive systems are typically used with threaded rods and reinforcing bars bonded into drilled holes.

  8. Why is a wire brush of the correct diameter important during hole cleaning?

    Answer: It has to contact the hole walls to loosen dust stuck to them

    An undersized or worn brush won't scrub the walls, which leaves a dust film that cuts bond strength.

  9. Which PPE is most appropriate when handling two-part epoxy adhesives?

    Answer: Chemical-resistant nitrile gloves and safety glasses

    Nitrile gloves resist epoxy penetration and eye protection guards against splashes.

  10. What is the recommended approach to staying current in Mechanical Systems & Maintenance?

    Answer: Regular professional development, industry publications, and peer collaboration

    Staying current in Mechanical Systems & Maintenance requires ongoing professional development, reading industry publications, and collaborating with peers to share knowledge and best practices.

  11. Which tool practice best reduces silica dust when blowing out an anchor hole?

    Answer: Use a HEPA vacuum or dust extraction instead of dry-sweeping or open blowing where permitted by the MPII

    Capturing dust with HEPA extraction limits exposure while still achieving required hole cleanliness.

  12. An anchor is bumped and turned a few minutes after installation, before the cure time has passed. What is the concern?

    Answer: The adhesive bond may be disturbed and the anchor may need to be replaced

    Moving an anchor between gel time and full cure can damage the bond, so report it and evaluate it.

  13. Under ACI 318, how old must the concrete be, at minimum, when adhesive anchors are installed?

    Answer: 21 days

    ACI 318 requires the concrete to be at least 21 days old when adhesive anchors are installed.

  14. How should a GFCI be checked on the job site?

    Answer: By pressing the TEST button before use to confirm it trips

    Pressing TEST and confirming the trip verifies the GFCI is functioning.

  15. Why is using compressed air from an oil-lubricated compressor a compliance concern when cleaning anchor holes?

    Answer: Oil contamination can reduce adhesive bond strength

    MPIIs typically require oil-free compressed air because oil on the hole surface weakens the bond.

  16. Under OSHA construction rules, which temporary receptacles used by workers require GFCI protection when not part of permanent wiring?

    Answer: All 120-volt, single-phase, 15- and 20-ampere receptacle outlets

    OSHA 1926.404(b)(1) requires GFCI protection on 120 V, single-phase, 15 and 20 A temporary receptacles unless an assured grounding program is used.

  17. What must structures in Seismic Design Categories C through F use when they rely on adhesive anchors?

    Answer: Anchors qualified for seismic loading under ACI 355.4

    ACI 318 requires anchors in SDC C–F to be qualified for earthquake loading through the seismic tests in ACI 355.4.

  18. At approximately what ground-fault current does a typical personnel GFCI trip?

    Answer: About 5 mA

    Personnel GFCIs trip at roughly 4–6 mA to prevent dangerous shock.

  19. How should empty adhesive cartridges and partially cured adhesive waste generally be disposed of?

    Answer: According to the SDS and local environmental regulations

    The SDS disposal section and local rules govern chemical waste disposal.

  20. What documentation is required for adhesive anchor installations?

    Answer: Material certifications, installation records, and inspection reports.

    Required documentation for adhesive anchor installations includes material certifications, installation records, and inspection reports. This comprehensive documentation provides a verifiable history of the installation, confirming that specified materials were used and procedures were followed correctly. Such records are crucial for quality assurance, compliance with building codes, and for future maintenance or auditing purposes.