  1. Before drilling anchor holes into an existing slab that may contain embedded electrical conduit, what is the best practice?

    Answer: Scan the area with GPR or another concrete scanning method and mark embedded items

    Scanning locates embedded conduit, rebar, and cables so holes can be shifted before drilling.

  2. Under OSHA construction rules, which temporary receptacles used by workers require GFCI protection when not part of permanent wiring?

    Answer: All 120-volt, single-phase, 15- and 20-ampere receptacle outlets

    OSHA 1926.404(b)(1) requires GFCI protection on 120 V, single-phase, 15 and 20 A temporary receptacles unless an assured grounding program is used.

  3. If your drill bit strikes what appears to be embedded electrical conduit, what should you do first?

    Answer: Stop drilling, keep clear, and notify the supervisor so the circuit can be de-energized and evaluated

    Striking conduit creates a shock and damage hazard, so work stops until the circuit is de-energized and the engineer decides on relocation.

  4. What type of extension cord is required for portable tools on a construction site?

    Answer: Cord designated for hard or extra-hard usage

    OSHA requires extension cords on construction sites to be rated for hard or extra-hard usage.

  5. Using a very long, undersized extension cord with a hammer drill most likely causes what problem?

    Answer: Voltage drop that reduces power and can overheat the motor

    Long, thin cords cause voltage drop, making the tool draw more current and run hot.

  6. What marking identifies a double-insulated power tool?

    Answer: A square within a square symbol

    The square-within-a-square symbol indicates double insulation.

  7. During your pre-use check you find a drill cord with exposed copper conductors. What should you do?

    Answer: Remove the tool from service and tag it out until repaired or replaced

    Damaged cords with exposed conductors must be taken out of service immediately.