← All AAI Flashcard Decks

Code Compliance & Standards Flashcards

7 cards from real AAI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Code Compliance & Standards flashcards as text
  1. In ACI 318, what lightweight concrete modification factor λa applies to adhesive anchor bond failure?

    Answer: 0.6λ

    ACI 318 uses λa = 0.6λ for adhesive anchor bond failure in lightweight concrete.

  2. Who normally checks adhesive expiration dates, hole dimensions, and hole cleaning during inspected adhesive anchor work?

    Answer: The special inspector

    The special inspector verifies the product, its expiration date, hole drilling, cleaning, and installation against the approved documents.

  3. The ESR for an adhesive lists only hammer-drilled holes. What should be done before using a core drill?

    Answer: Confirm that core drilling is qualified for the product or get engineer approval

    Bond strength depends on the drilling method, so only methods qualified in the ESR or MPII are allowed without approval.

  4. Which installation moisture condition may be allowed only if the product's ESR specifically qualifies it?

    Answer: Water-filled holes

    Water-filled and submerged holes are allowed only when the product has been qualified for those conditions.

  5. What must structures in Seismic Design Categories C through F use when they rely on adhesive anchors?

    Answer: Anchors qualified for seismic loading under ACI 355.4

    ACI 318 requires anchors in SDC C–F to be qualified for earthquake loading through the seismic tests in ACI 355.4.

  6. What does the ACI/CRSI Adhesive Anchor Installer certification process include?

    Answer: A written exam and a performance (hands-on) exam

    Candidates must pass both a written exam and a practical performance exam to be certified.

  7. Which document should state that installer certification and inspection are required for adhesive anchors?

    Answer: The construction documents

    ACI 318 requires the construction documents to list the installer certification and inspection requirements for adhesive anchors.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. concrete.org — Fees, retake fee, test delivery, exam format, passing score, renewal, time limit, score validity, score release, eligibility · verified Nov 2026